{"title":"Italweber","description":"\u003cp\u003eItalweber here covers string protection on the DC side: \u003cstrong\u003e1000VDC PV fuses\u003c\/strong\u003e in 10A, 16A and 20A, and a one-module DIN holder for 10x38mm elements rated 32A at 1000V DC, single pole.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe 1000VDC rating is the point of these parts.\u003c\/strong\u003e A fuse built for AC or for a lower DC voltage cannot break a PV string, where current keeps flowing as long as there is light; the 10x38mm format keeps the board compact while holding that rating.\u003c\/p\u003e\u003cp\u003eFuse and holder are ordered separately: the holder takes 10x38mm elements up to 32A, so the 10A, 16A or 20A fuse is chosen on the string, not on the holder.\u003c\/p\u003e","products":[{"product_id":"fusibile-per-impianto-fotovoltaico-italweber-10a-1000vdc-italweber","title":"Italweber Fuse for photovoltaic systems Italweber 10A - 1000VDC","description":"\u003cdiv class=\"litio-shipping-note\" style=\"margin:0 0 18px;padding:11px 14px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:13px;line-height:1.45;\"\u003e\n  \u003cstrong style=\"font-weight:700;color:#0e1b4d;\"\u003eShipping costs\u003c\/strong\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eItaly:\u003c\/strong\u003e free over €150; €13 for smaller orders.\u003c\/span\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eEuropean Union:\u003c\/strong\u003e free over €350; €60 for smaller orders.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch1\u003eDelivery in 1-4 days.\u003c\/h1\u003e\n\u003cp\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eFuse for Italweber photovoltaic systems 10A - 1000VDC Italweber\u003c\/p\u003e\n\n\n\n\u003cp\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Italweber","offers":[{"title":"Default Title","offer_id":47754224894289,"sku":null,"price":4.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/italweber-fusibile-per-impianto-fotovoltaico-10a-1000vdc-372.webp?v=1748264205"},{"product_id":"fusibile-per-impianto-fotovoltaico-italweber-20a-1000vdc-italweber","title":"Italweber Fuse for photovoltaic systems Italweber 20A - 1000VDC","description":"\u003cdiv class=\"litio-shipping-note\" style=\"margin:0 0 18px;padding:11px 14px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:13px;line-height:1.45;\"\u003e\n  \u003cstrong style=\"font-weight:700;color:#0e1b4d;\"\u003eShipping costs\u003c\/strong\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eItaly:\u003c\/strong\u003e free over €150; €13 for smaller orders.\u003c\/span\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eEuropean Union:\u003c\/strong\u003e free over €350; €60 for smaller orders.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eReady to ship in 1-4 days.\u003c\/h2\u003e\n\n\u003cp style=\"padding-left: 30px;\"\u003eFuse for Italweber photovoltaic systems 20A - 1000VDC Italweber\u003c\/p\u003e\n\n\n\n\n\u003cul\u003e\u003c\/ul\u003e","brand":"Italweber","offers":[{"title":"Default Title","offer_id":47754220994897,"sku":null,"price":4.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/italweber-fusibile-per-impianto-fotovoltaico-20a-1000vdc-256.webp?v=1748264210"},{"product_id":"italweber-fusibile-per-impianto-fotovoltaico-italweber-16a-1000vdc","title":"Italweber Fuse for photovoltaic systems Italweber 16A - 1000VDC","description":"\u003cdiv class=\"litio-shipping-note\" style=\"margin:0 0 18px;padding:11px 14px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:13px;line-height:1.45;\"\u003e\n  \u003cstrong style=\"font-weight:700;color:#0e1b4d;\"\u003eShipping costs\u003c\/strong\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eItaly:\u003c\/strong\u003e free over €150; €13 for smaller orders.\u003c\/span\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eEuropean Union:\u003c\/strong\u003e free over €350; €60 for smaller orders.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eReady to ship in 1-4 days.\u003c\/h2\u003e\n\n\u003cp style=\"padding-left: 30px;\"\u003eFuse for Italweber photovoltaic systems 16A - 1000VDC Italweber\u003c\/p\u003e\n\n\n\n\n\u003cul\u003e\u003c\/ul\u003e","brand":"Italweber","offers":[{"title":"Default Title","offer_id":48699874804049,"sku":null,"price":4.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/italweber-fusibile-per-impianto-fotovoltaico-16a-1000vdc-340.webp?v=1748266790"},{"product_id":"italweber-portafusibile-32-a-dc-1000-v-10-x-38-mm-1-polo-per-fotovoltaico-1-modulo-din","title":"ITALWEBER Fuse Holder 32A DC 1000V 10 x 38 mm 1-pole - for photovoltaic - 1 DIN module","description":"\u003cdiv class=\"litio-shipping-note\" style=\"margin:0 0 18px;padding:11px 14px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:13px;line-height:1.45;\"\u003e\n  \u003cstrong style=\"font-weight:700;color:#0e1b4d;\"\u003eShipping costs\u003c\/strong\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eItaly:\u003c\/strong\u003e free over €150; €13 for smaller orders.\u003c\/span\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eEuropean Union:\u003c\/strong\u003e free over €350; €60 for smaller orders.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch1\u003eDelivery in 1-4 days.\u003c\/h1\u003e\n\u003cp\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e\u003cstrong\u003eITALWEBER\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003e32A DC 1000V fuse holder\u003c\/p\u003e\n\u003cp style=\"padding-left: 30px;\"\u003eFor 10 x 38 mm 1-pole fuses - for photovoltaic systems - DIN rail mounting\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Italweber","offers":[{"title":"Default Title","offer_id":48700009480529,"sku":null,"price":7.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/italweber-portafusibile-32-a-dc-1000-v-10-x-38-mm-1-polo-541.webp?v=1748266795"},{"product_id":"fusibile-per-impianto-fotovoltaico-italweber-20a-1000vdc-gpv20","title":"Fuse for photovoltaic systems Italweber 20A - 1000VDC","description":"\u003cdiv class=\"litio-shipping-note\" style=\"margin:0 0 18px;padding:11px 14px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:13px;line-height:1.45;\"\u003e\n  \u003cstrong style=\"font-weight:700;color:#0e1b4d;\"\u003eShipping costs\u003c\/strong\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eItaly:\u003c\/strong\u003e free over €150; €13 for smaller orders.\u003c\/span\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eEuropean Union:\u003c\/strong\u003e free over €350; €60 for smaller orders.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:28px;border-radius:8px;margin-bottom:24px;text-align:center;\"\u003e\n  \u003ch1 class=\"heading\" style=\"font-size:22px;margin:0 0 8px;color:#fff;\"\u003eFuse for Solar Systems Italweber 20A - 1000VDC\u003c\/h1\u003e\n  \u003cdiv style=\"display:inline-block;background:#eaf5d6;color:#4a7a02;font-weight:700;font-size:13px;padding:6px 14px;border-radius:20px;margin-top:8px;\"\u003e🚚 Fast delivery in 10-20 days\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-size:15px;color:#333;line-height:1.7;\"\u003e10×38 cylindrical fuse, 20A, ideal for protecting the DC power line between solar panels and the charge controller or inverter input.\u003c\/p\u003e","brand":"Italweber","offers":[{"title":"Default Title","offer_id":54700503007569,"sku":"GPV20-IVA10","price":5.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/fusibile-per-impianto-fotovoltaico-italweber-20a-1000vdc-italweber.jpg?v=1787797879"},{"product_id":"fusibile-per-impianto-fotovoltaico-italweber-10a-1000vdc-gpv10","title":"Fuse for photovoltaic systems Italweber 10A - 1000VDC","description":"\u003cdiv class=\"litio-shipping-note\" style=\"margin:0 0 18px;padding:11px 14px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:13px;line-height:1.45;\"\u003e\n  \u003cstrong style=\"font-weight:700;color:#0e1b4d;\"\u003eShipping costs\u003c\/strong\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eItaly:\u003c\/strong\u003e free over €150; €13 for smaller orders.\u003c\/span\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eEuropean Union:\u003c\/strong\u003e free over €350; €60 for smaller orders.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:28px;border-radius:8px;margin-bottom:24px;text-align:center;\"\u003e\n  \u003ch1 class=\"heading\" style=\"font-size:22px;margin:0 0 8px;color:#fff;\"\u003eFuse for Solar Systems Italweber 10A - 1000VDC\u003c\/h1\u003e\n  \u003cdiv style=\"display:inline-block;background:#eaf5d6;color:#4a7a02;font-weight:700;font-size:13px;padding:6px 14px;border-radius:20px;margin-top:8px;\"\u003e🚚 Fast delivery in 10-20 days\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-size:15px;color:#333;line-height:1.7;\"\u003e10×38 cylindrical fuse, 10A, ideal for protecting the DC power line between solar panels and the charge controller or inverter input.\u003c\/p\u003e","brand":"Italweber","offers":[{"title":"Default Title","offer_id":54700503630161,"sku":"GPV10","price":4.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/fusibile-per-impianto-fotovoltaico-italweber-10a-1000vdc-italweber.jpg?v=1787797898"},{"product_id":"fusibile-per-impianto-fotovoltaico-italweber-16a-1000vdc-gpv16","title":"Fuse for photovoltaic systems Italweber 16A - 1000VDC","description":"\u003cdiv class=\"litio-shipping-note\" style=\"margin:0 0 18px;padding:11px 14px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:13px;line-height:1.45;\"\u003e\n  \u003cstrong style=\"font-weight:700;color:#0e1b4d;\"\u003eShipping costs\u003c\/strong\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eItaly:\u003c\/strong\u003e free over €150; €13 for smaller orders.\u003c\/span\u003e\u003cbr\u003e\n  \u003cspan\u003e\u003cstrong\u003eEuropean Union:\u003c\/strong\u003e free over €350; €60 for smaller orders.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:28px;border-radius:8px;margin-bottom:24px;text-align:center;\"\u003e\n  \u003ch1 class=\"heading\" style=\"font-size:22px;margin:0 0 8px;color:#fff;\"\u003eFuse for Solar Systems Italweber 16A - 1000VDC\u003c\/h1\u003e\n  \u003cdiv style=\"display:inline-block;background:#eaf5d6;color:#4a7a02;font-weight:700;font-size:13px;padding:6px 14px;border-radius:20px;margin-top:8px;\"\u003e🚚 Fast delivery in 10-20 days\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:'Open Sans',sans-serif;font-size:15px;color:#333;line-height:1.7;\"\u003e10×38 cylindrical fuse, 16A, ideal for protecting the DC power line between solar panels and the charge controller or inverter input.\u003c\/p\u003e","brand":"Italweber","offers":[{"title":"Default Title","offer_id":54700504023377,"sku":"GPV16","price":5.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/fusibile-per-impianto-fotovoltaico-italweber-16a-1000vdc-italweber.jpg?v=1787797916"},{"product_id":"fusibile-nh-gpv-1000v-cc-italweber-100a-400a-per-quadri-di-accumulo-e-stringhe-fotovoltaiche","title":"NH gPV fuse link 1000V DC 100A-400A for storage switchboards and PV strings","description":"\u003cstyle\u003e\n.nhf-wrap{font-family:'Open Sans',sans-serif;font-size:16px;line-height:1.75;color:#222}\n.nhf-wrap h2{font-family:'Rajdhani',sans-serif;font-size:24px;color:#0e1b4d;margin:34px 0 14px;font-weight:700}\n.nhf-wrap p,.nhf-wrap li{font-size:16px}\n.nhf-wrap ul{padding-left:22px}\n.nhf-wrap li{margin-bottom:8px}\n.nhf-sc{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:14px 0 6px}\n.nhf-t{width:100%;border-collapse:collapse;font-family:'Tomorrow',sans-serif}\n.nhf-t.wide{min-width:700px}\n.nhf-t th{background:#0e1b4d;color:#fff;font-size:15px;padding:12px 14px;text-align:left;font-weight:700;white-space:nowrap}\n.nhf-t td{border:1px solid #ddd;font-size:15px;padding:12px 14px;background:#fff;vertical-align:top}\n.nhf-t tr:nth-child(even) td{background:#f7f8fa}\n.nhf-lab{background:#f0f0f0!important;color:#0e1b4d;font-weight:700}\n.nhf-g{color:#73aa02;font-weight:700}\n.nhf-box{background:#f4f7ec;border-left:5px solid #73aa02;padding:18px 20px;border-radius:6px;margin:22px 0}\n.nhf-box2{background:#fffbea;border:1px solid #ffd700;padding:18px 20px;border-radius:6px;margin:22px 0}\n.nhf-hint{display:none;font-size:14px;color:#777;margin:0 0 10px}\n@media (max-width:749px){\n.nhf-wrap h2{font-size:21px}\n.nhf-t th,.nhf-t td{padding:10px 12px;font-size:14px}\n.nhf-hint{display:block}\n.nhf-sc{border:1px solid #e3e6ec;border-radius:6px}\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"nhf-wrap\"\u003e\n\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:30px 26px;border-radius:8px;margin-bottom:26px;text-align:center;\"\u003e\n  \u003ch2 style=\"font-family:'Rajdhani',sans-serif;font-size:26px;margin:0 0 10px;color:#fff;font-weight:700;\"\u003eNH gPV fuse link 1000V DC\u003c\/h2\u003e\n  \u003cp style=\"font-size:17px;margin:0;color:#fff;opacity:.92;\"\u003eSwitchboard protection, where the job calls for inspectable NH isolation\u003c\/p\u003e\n  \u003cp style=\"font-size:16px;margin:10px 0 0;color:#73aa02;font-weight:700;\"\u003e1000V DC \u0026middot; 20kA breaking capacity \u0026middot; sizes from 100A to 400A\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eA knife-blade fuse link in NH format for DC circuits, rated \u003cstrong\u003e1000V DC\u003c\/strong\u003e with a \u003cstrong\u003e20kA\u003c\/strong\u003e breaking capacity. This is what you fit when the switchboard is industrial and the specification asks for an isolating device that can be inspected, replaced on sight, and that accepts cable cross-sections up to 240mm\u0026sup2;.\u003c\/p\u003e\n\n\u003cdiv class=\"nhf-box2\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003e\u003cstrong\u003eRead this before ordering.\u003c\/strong\u003e An NH fuse link has \u003cstrong\u003eno threaded holes\u003c\/strong\u003e: it has two blades that push into the clips of a fuse base. \u003cstrong\u003eThe cable lands on the base terminals, never on the fuse.\u003c\/strong\u003e So you always need an NH base of the matching size — NH0 goes on PK0, NH1 on PK1, NH2 on PK2, NH3 on PK3 — and the base is not included. For the same reason an NH fuse \u003cstrong\u003edoes not fit a Victron Lynx Distributor or a Lynx Class-T Power In\u003c\/strong\u003e: those modules are built for bolt-down fuses.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical data\u003c\/h2\u003e\n\n\u003cdiv class=\"nhf-sc\"\u003e\n\u003ctable class=\"nhf-t\"\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eRated voltage\u003c\/td\u003e\u003ctd\u003e1000V DC\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eBreaking capacity\u003c\/td\u003e\u003ctd\u003e20kA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eType\u003c\/td\u003e\u003ctd\u003egPV, to IEC 60269-6\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eContact\u003c\/td\u003e\u003ctd\u003eknife blade, for an NH fuse base\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eSizes\u003c\/td\u003e\u003ctd\u003eNH0 100A \u0026middot; NH0 125A \u0026middot; NH0 160A \u0026middot; NH2 250A \u0026middot; NH3 160A \u0026middot; NH3 250A \u0026middot; NH3 400A\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eMatching base\u003c\/td\u003e\u003ctd\u003eNH0 \u0026rarr; PK0 160A \u0026middot; NH2 \u0026rarr; PK2 400A \u0026middot; NH3 \u0026rarr; PK3 630A\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eManufacturer pack\u003c\/td\u003e\u003ctd\u003e3 pieces per size\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eOrigin\u003c\/td\u003e\u003ctd\u003eSlovenia\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003egPV and gBat: the honest version\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003egPV\u003c\/strong\u003e is tested to \u003cstrong\u003eIEC 60269-6\u003c\/strong\u003e against photovoltaic sources, which are current-limited and have short time constants. The type tested against battery circuits is \u003cstrong\u003egBat\u003c\/strong\u003e, \u003cstrong\u003eIEC 60269-7\u003c\/strong\u003e, designed for much higher prospective short-circuit currents and longer L\/R time constants. On a 51.2V bank a 1000V gPV runs at roughly 5% of its rated voltage, which is a very conservative application, and 20kA is far above anything a 48V bank will deliver. It is not, however, the type formally tested for batteries, and we are not going to dress it up as something it is not. If your specification names gBat, write to us: it is a made-to-order item.\u003c\/p\u003e\n\n\u003ch2\u003eWhen to choose it\u003c\/h2\u003e\n\n\u003cdiv class=\"nhf-box\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003eIndustrial switchboards, installations where the design calls for NH isolation, where cable goes beyond 120mm\u0026sup2;, or where the storage panel already sits on steelwork with NH bases for the other ways. For a domestic system built around a Victron Lynx busbar, the right fuse is still the MEGA 80V or the Class T: they cost far less and bolt straight onto the bar.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eHow it is installed\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003eMount the \u003cstrong\u003eNH base\u003c\/strong\u003e of the matching size on the panel, with its fixing screws.\u003c\/li\u003e\n\u003cli\u003eLand the power cables with ring lugs on the \u003cstrong\u003ebolted terminals of the base\u003c\/strong\u003e, at the specified torque.\u003c\/li\u003e\n\u003cli\u003eInsert the fuse into the clips with an NH handle, with the system isolated.\u003c\/li\u003e\n\u003cli\u003eThe base is \u003cstrong\u003esingle pole\u003c\/strong\u003e: one per way for the positive alone, doubled if the design protects both poles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMEGA, Class T or NH: which fuse to choose\u003c\/h2\u003e\n\u003cp\u003eThree fuse families are actually used on the DC side of a 48V battery system, and they are interchangeable neither mechanically nor in performance.\u003c\/p\u003e\n\u003cp class=\"nhf-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"nhf-sc\"\u003e\n\u003ctable class=\"nhf-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003e\u0026nbsp;\u003c\/th\u003e\u003cth\u003eVictron MEGA 80V\u003c\/th\u003e\u003cth\u003eClass T\u003c\/th\u003e\u003cth\u003eNH gPV 1000V DC\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eDC voltage rating\u003c\/td\u003e\u003ctd\u003e80V\u003c\/td\u003e\u003ctd\u003e125V fuse \/ 160V holder\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhf-g\"\u003e1000V\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eDC interrupting rating\u003c\/td\u003e\u003ctd\u003enot published by the manufacturer\u003c\/td\u003e\u003ctd\u003e20,000A\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhf-g\"\u003e20kA\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eConnection\u003c\/td\u003e\u003ctd\u003edirect M8 bolt, 50.8mm hole centres\u003c\/td\u003e\u003ctd\u003e3\/8\" studs (225-400A) or M8 (110-200A)\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhf-g\"\u003eknife contacts: the cable lands on the \u003cstrong\u003ebase\u003c\/strong\u003e, never on the fuse\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eWhere it mounts\u003c\/td\u003e\u003ctd\u003ealready built into the Victron Lynx Distributor, with a status LED per position\u003c\/td\u003e\u003ctd\u003eVictron Lynx Class-T Power In (2 positions, M10 busbar) or a stand-alone holder\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhf-g\"\u003eNH fuse base PK0\/PK1\/PK2\/PK3, screw-mounted on the panel\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhf-lab\"\u003eWhen to pick it\u003c\/td\u003e\u003ctd\u003eresidential and light commercial systems built around a Lynx busbar: the most compact and the cheapest\u003c\/td\u003e\u003ctd\u003elarge LiFePO4 banks, where a published DC interrupting rating matters. The reference choice in marine and professional off-grid\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhf-g\"\u003eindustrial switchboards, inspectable isolation, cable up to 240mm\u0026sup2;\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eDelivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDelivered in \u003cstrong\u003e10-20 days\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eShipping across Italy and the European Union\u003c\/li\u003e\n\u003cli\u003eNot sure which size you need? Send us the maximum discharge current from your battery manual and the cable cross-section, and we will tell you\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Italweber","offers":[{"title":"NH0 100A","offer_id":55331965272401,"sku":"1660100","price":171.46,"currency_code":"EUR","in_stock":true},{"title":"NH0 125A","offer_id":55331965305169,"sku":"1660125","price":171.46,"currency_code":"EUR","in_stock":true},{"title":"NH0 160A","offer_id":55331965337937,"sku":"1660160","price":171.46,"currency_code":"EUR","in_stock":true},{"title":"NH2 250A","offer_id":55331965370705,"sku":"1662249","price":318.78,"currency_code":"EUR","in_stock":true},{"title":"NH3 160A","offer_id":55331965403473,"sku":"1662160","price":341.39,"currency_code":"EUR","in_stock":true},{"title":"NH3 250A","offer_id":55331965436241,"sku":"1662250","price":341.39,"currency_code":"EUR","in_stock":true},{"title":"NH3 400A","offer_id":55331965469009,"sku":"1662400","price":382.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/fusibile-nh-gpv-1000v-cc-italweber-100a-400a.png?v=1792151810"},{"product_id":"base-portafusibili-nh-1000v-cc-italweber-pk0-pk3-da-160a-a-630a-con-morsetti-a-bullone","title":"NH fuse base 1000V DC PK0-PK3 from 160A to 630A with bolted terminals","description":"\u003cstyle\u003e\n.nhb-wrap{font-family:'Open Sans',sans-serif;font-size:16px;line-height:1.75;color:#222}\n.nhb-wrap h2{font-family:'Rajdhani',sans-serif;font-size:24px;color:#0e1b4d;margin:34px 0 14px;font-weight:700}\n.nhb-wrap p,.nhb-wrap li{font-size:16px}\n.nhb-wrap ul{padding-left:22px}\n.nhb-wrap li{margin-bottom:8px}\n.nhb-sc{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:14px 0 6px}\n.nhb-t{width:100%;border-collapse:collapse;font-family:'Tomorrow',sans-serif}\n.nhb-t.wide{min-width:700px}\n.nhb-t th{background:#0e1b4d;color:#fff;font-size:15px;padding:12px 14px;text-align:left;font-weight:700;white-space:nowrap}\n.nhb-t td{border:1px solid #ddd;font-size:15px;padding:12px 14px;background:#fff;vertical-align:top}\n.nhb-t tr:nth-child(even) td{background:#f7f8fa}\n.nhb-lab{background:#f0f0f0!important;color:#0e1b4d;font-weight:700}\n.nhb-g{color:#73aa02;font-weight:700}\n.nhb-box{background:#f4f7ec;border-left:5px solid #73aa02;padding:18px 20px;border-radius:6px;margin:22px 0}\n.nhb-box2{background:#fffbea;border:1px solid #ffd700;padding:18px 20px;border-radius:6px;margin:22px 0}\n.nhb-hint{display:none;font-size:14px;color:#777;margin:0 0 10px}\n@media (max-width:749px){\n.nhb-wrap h2{font-size:21px}\n.nhb-t th,.nhb-t td{padding:10px 12px;font-size:14px}\n.nhb-hint{display:block}\n.nhb-sc{border:1px solid #e3e6ec;border-radius:6px}\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"nhb-wrap\"\u003e\n\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:30px 26px;border-radius:8px;margin-bottom:26px;text-align:center;\"\u003e\n  \u003ch2 style=\"font-family:'Rajdhani',sans-serif;font-size:26px;margin:0 0 10px;color:#fff;font-weight:700;\"\u003eNH fuse base 1000V DC\u003c\/h2\u003e\n  \u003cp style=\"font-size:17px;margin:0;color:#fff;opacity:.92;\"\u003eThe part that holds the NH fuse and takes the power cable\u003c\/p\u003e\n  \u003cp style=\"font-size:16px;margin:10px 0 0;color:#73aa02;font-weight:700;\"\u003e1000V DC \u0026middot; 160A to 630A \u0026middot; bolted terminals to 300mm\u0026sup2;\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eA single-pole fuse base for NH knife-blade fuse links in DC circuits, rated \u003cstrong\u003e1000V DC\u003c\/strong\u003e. It is the piece everyone forgets when ordering NH fuses: the fuse on its own connects to nothing, because it has two blades and no threaded holes. \u003cstrong\u003eThe cables land here\u003c\/strong\u003e, on the bolted terminals of the base, and the fuse pushes into the clips.\u003c\/p\u003e\n\n\u003cdiv class=\"nhb-box2\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003e\u003cstrong\u003eTwo things to know before ordering.\u003c\/strong\u003e The \u003cstrong\u003efuse is not included\u003c\/strong\u003e and must match the size of the base: NH0 on PK0, NH1 on PK1, NH2 on PK2, NH3 on PK3. And the base is \u003cstrong\u003esingle pole\u003c\/strong\u003e: one per way if you protect the positive alone, doubled if the design calls for protection on both poles.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eSizes and connections\u003c\/h2\u003e\n\n\u003cp class=\"nhb-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"nhb-sc\"\u003e\n\u003ctable class=\"nhb-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003eBase\u003c\/th\u003e\u003cth\u003eFuse size\u003c\/th\u003e\u003cth\u003eCurrent\u003c\/th\u003e\u003cth\u003eBolts\u003c\/th\u003e\u003cth\u003eCable\u003c\/th\u003e\u003cth\u003eTorque\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003ePK0\u003c\/td\u003e\u003ctd\u003eNH0\u003c\/td\u003e\u003ctd\u003e160A\u003c\/td\u003e\u003ctd\u003eM8-M8\u003c\/td\u003e\u003ctd\u003e25-150mm\u0026sup2;\u003c\/td\u003e\u003ctd\u003e32Nm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003ePK1\u003c\/td\u003e\u003ctd\u003eNH1\u003c\/td\u003e\u003ctd\u003e250A\u003c\/td\u003e\u003ctd\u003eM10-M10\u003c\/td\u003e\u003ctd\u003e25-150mm\u0026sup2;\u003c\/td\u003e\u003ctd\u003e32Nm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003ePK2\u003c\/td\u003e\u003ctd\u003eNH2\u003c\/td\u003e\u003ctd\u003e400A\u003c\/td\u003e\u003ctd\u003eM10-M10\u003c\/td\u003e\u003ctd\u003e25-240mm\u0026sup2;\u003c\/td\u003e\u003ctd\u003e32Nm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003ePK3\u003c\/td\u003e\u003ctd\u003eNH3\u003c\/td\u003e\u003ctd\u003e630A\u003c\/td\u003e\u003ctd\u003eM12-M12\u003c\/td\u003e\u003ctd\u003e25-300mm\u0026sup2;\u003c\/td\u003e\u003ctd\u003e32Nm\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:15px;color:#555;margin-top:4px;\"\u003eAll sizes 1000V DC, single pole, screw fixing. Dimensions PK1 55\u0026times;198\u0026times;83.6mm, PK2 65\u0026times;225\u0026times;89mm. If your installation is close to the cross-section limit, check the lug against the data sheet before ordering.\u003c\/p\u003e\n\n\u003ch2\u003eWhich one for 50 and 70mm\u0026sup2; cable\u003c\/h2\u003e\n\n\u003cdiv class=\"nhb-box\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003eAll four take \u003cstrong\u003e50mm\u0026sup2;\u003c\/strong\u003e lugs without argument, because the terminals are bolted and any ring lug will go on. For \u003cstrong\u003e70mm\u0026sup2;\u003c\/strong\u003e the PK0 has \u003cstrong\u003eM8\u003c\/strong\u003e bolts, and a 70mm\u0026sup2; lug with an M8 hole is a stretch: from \u003cstrong\u003ePK1 upwards\u003c\/strong\u003e the bolts are M10 or M12 and the joint is clean. On a 48V battery way with 70mm\u0026sup2; cable, the natural choice is the \u003cstrong\u003ePK1 250A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eHow it is installed\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe base screws to the panel or mounting plate.\u003c\/li\u003e\n\u003cli\u003ePower cables land on the terminals with ring lugs, tightened to the stated torque.\u003c\/li\u003e\n\u003cli\u003eThe fuse goes in and out with an \u003cstrong\u003eNH handle\u003c\/strong\u003e, always with the system isolated.\u003c\/li\u003e\n\u003cli\u003eKeep the front of the base accessible: that is the whole advantage of NH over a bolt-down fuse, replacement on sight without disturbing the cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMEGA, Class T or NH: which fuse to choose\u003c\/h2\u003e\n\u003cp\u003eThree fuse families are actually used on the DC side of a 48V battery system, and they are interchangeable neither mechanically nor in performance.\u003c\/p\u003e\n\u003cp class=\"nhb-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"nhb-sc\"\u003e\n\u003ctable class=\"nhb-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003e\u0026nbsp;\u003c\/th\u003e\u003cth\u003eVictron MEGA 80V\u003c\/th\u003e\u003cth\u003eClass T\u003c\/th\u003e\u003cth\u003eNH gPV 1000V DC\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003eDC voltage rating\u003c\/td\u003e\u003ctd\u003e80V\u003c\/td\u003e\u003ctd\u003e125V fuse \/ 160V holder\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhb-g\"\u003e1000V\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003eDC interrupting rating\u003c\/td\u003e\u003ctd\u003enot published by the manufacturer\u003c\/td\u003e\u003ctd\u003e20,000A\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhb-g\"\u003e20kA\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003eConnection\u003c\/td\u003e\u003ctd\u003edirect M8 bolt, 50.8mm hole centres\u003c\/td\u003e\u003ctd\u003e3\/8\" studs (225-400A) or M8 (110-200A)\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhb-g\"\u003eknife contacts: the cable lands on the \u003cstrong\u003ebase\u003c\/strong\u003e, never on the fuse\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003eWhere it mounts\u003c\/td\u003e\u003ctd\u003ealready built into the Victron Lynx Distributor, with a status LED per position\u003c\/td\u003e\u003ctd\u003eVictron Lynx Class-T Power In (2 positions, M10 busbar) or a stand-alone holder\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhb-g\"\u003eNH fuse base PK0\/PK1\/PK2\/PK3, screw-mounted on the panel\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"nhb-lab\"\u003eWhen to pick it\u003c\/td\u003e\u003ctd\u003eresidential and light commercial systems built around a Lynx busbar: the most compact and the cheapest\u003c\/td\u003e\u003ctd\u003elarge LiFePO4 banks, where a published DC interrupting rating matters. The reference choice in marine and professional off-grid\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"nhb-g\"\u003eindustrial switchboards, inspectable isolation, cable up to 240mm\u0026sup2;\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eDelivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDelivered in \u003cstrong\u003e10-20 days\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eShipping across Italy and the European Union\u003c\/li\u003e\n\u003cli\u003eNot sure which size you need? Send us the maximum discharge current from your battery manual and the cable cross-section, and we will tell you\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Italweber","offers":[{"title":"PK0 160A - NH0","offer_id":55331965665617,"sku":"2640014P","price":15.4,"currency_code":"EUR","in_stock":true},{"title":"PK1 250A - NH1","offer_id":55331965698385,"sku":"2540016P","price":44.71,"currency_code":"EUR","in_stock":true},{"title":"PK2 400A - NH2","offer_id":55331965731153,"sku":"2540017P","price":75.87,"currency_code":"EUR","in_stock":true},{"title":"PK3 630A - NH3","offer_id":55331965763921,"sku":"2540018P","price":112.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/base-portafusibili-nh-1000v-cc-italweber-pk0-pk3.png?v=1792151810"},{"product_id":"kit-protezioni-batteria-nh-1000v-cc-per-inverter-ibrido-da-5kw-a-20kw-con-basi-portafusibili-barra-victron-lynx-cavi-e-capicorda-per-1-4-batterie-in-parallelo","title":"NH 1000V DC battery protection kit for 5kW to 20kW hybrid inverters with fuse bases, Victron Lynx busbar, cable and lugs for 1-4 batteries in parallel","description":"\u003cstyle\u003e\n.knh-wrap{font-family:'Open Sans',sans-serif;font-size:16px;line-height:1.75;color:#222}\n.knh-wrap h2{font-family:'Rajdhani',sans-serif;font-size:24px;color:#0e1b4d;margin:34px 0 14px;font-weight:700}\n.knh-wrap p,.knh-wrap li{font-size:16px}\n.knh-wrap ul{padding-left:22px}\n.knh-wrap li{margin-bottom:8px}\n.knh-sc{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:14px 0 6px}\n.knh-t{width:100%;border-collapse:collapse;font-family:'Tomorrow',sans-serif}\n.knh-t.wide{min-width:700px}\n.knh-t th{background:#0e1b4d;color:#fff;font-size:15px;padding:12px 14px;text-align:left;font-weight:700;white-space:nowrap}\n.knh-t td{border:1px solid #ddd;font-size:15px;padding:12px 14px;background:#fff;vertical-align:top}\n.knh-t tr:nth-child(even) td{background:#f7f8fa}\n.knh-lab{background:#f0f0f0!important;color:#0e1b4d;font-weight:700}\n.knh-g{color:#73aa02;font-weight:700}\n.knh-box{background:#f4f7ec;border-left:5px solid #73aa02;padding:18px 20px;border-radius:6px;margin:22px 0}\n.knh-box2{background:#fffbea;border:1px solid #ffd700;padding:18px 20px;border-radius:6px;margin:22px 0}\n.knh-hint{display:none;font-size:14px;color:#777;margin:0 0 10px}\n@media (max-width:749px){\n.knh-wrap h2{font-size:21px}\n.knh-t th,.knh-t td{padding:10px 12px;font-size:14px}\n.knh-hint{display:block}\n.knh-sc{border:1px solid #e3e6ec;border-radius:6px}\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"knh-wrap\"\u003e\n\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:30px 26px;border-radius:8px;margin-bottom:26px;text-align:center;\"\u003e\n  \u003ch2 style=\"font-family:'Rajdhani',sans-serif;font-size:26px;margin:0 0 10px;color:#fff;font-weight:700;\"\u003eNH 1000V DC battery protection kit\u003c\/h2\u003e\n  \u003cp style=\"font-size:17px;margin:0;color:#fff;opacity:.92;\"\u003eThe industrial switchboard version, with inspectable NH isolation\u003c\/p\u003e\n  \u003cp style=\"font-size:16px;margin:10px 0 0;color:#73aa02;font-weight:700;\"\u003eNH gPV fuse links 1000V DC \u0026middot; fuse bases \u0026middot; Victron Lynx busbar \u0026middot; cable and lugs\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eThis kit contains the \u003cstrong\u003eprotection devices and the wiring only\u003c\/strong\u003e: the inverter and the batteries are not included. You pick the inverter size and how many 48V batteries go in parallel, and the right material arrives, already sized.\u003c\/p\u003e\n\u003cp\u003eIt is the \u003cstrong\u003eindustrial\u003c\/strong\u003e version of our protection kit. Instead of bolt-down fuses it carries \u003cstrong\u003eNH knife-blade fuse links\u003c\/strong\u003e rated \u003cspan class=\"knh-g\"\u003e1000V DC\u003c\/span\u003e with \u003cspan class=\"knh-g\"\u003e20kA\u003c\/span\u003e breaking capacity, each on its own fuse base. It is what specifications ask for when an inspectable isolating device is required, one that can be replaced in plain sight with an NH handle, and when the cables go beyond what an M8 stud can take.\u003c\/p\u003e\n\n\u003cdiv class=\"knh-box\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003e\u003cstrong style=\"color:#0e1b4d;\"\u003eHow it is built:\u003c\/strong\u003e an NH fuse has no threaded holes, it has two blades that slide into the clips of a \u003cstrong\u003efuse base\u003c\/strong\u003e, and it is on the base that the cables are terminated. That is why the kit always includes one base per protected branch. The batteries are paralleled on a \u003cstrong\u003eVictron Lynx Power In\u003c\/strong\u003e busbar with four connections, unfused, because here the protection sits upstream on the NH bases. With a single battery on a single-input inverter the busbar is not needed: the base and the in-line fuse remain.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhat the kit contains\u003c\/h2\u003e\n\u003cp\u003eEvery configuration arrives \u003cstrong\u003ecomplete and already sized\u003c\/strong\u003e: pick the inverter size above and how many 48V batteries you put in parallel, and the kit we ship carries all of the DC-side material.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe \u003cstrong\u003eVictron Lynx busbar\u003c\/strong\u003e, in the number of modules the configuration calls for\u003c\/li\u003e\n\u003cli\u003ethe \u003cstrong\u003eNH fuse bases\u003c\/strong\u003e and the \u003cstrong\u003eNH gPV 1000V DC fuses\u003c\/strong\u003e of the correct rating, on the battery side and on the inverter side\u003c\/li\u003e\n\u003cli\u003ethe \u003cstrong\u003epower cables\u003c\/strong\u003e in the cross-section the inverter manual prescribes for that current\u003c\/li\u003e\n\u003cli\u003ethe \u003cstrong\u003elugs\u003c\/strong\u003e already matched to the cables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWith \u003cstrong\u003ea single battery on a single-input inverter\u003c\/strong\u003e no busbar is needed: the kit comes down to in-line protection, and it is the cheapest configuration.\u003c\/p\u003e\n\u003cp\u003eThe piece count and the ratings change from one configuration to the next: we do the sizing. If you want the full bill of materials before ordering, send us the inverter model and the battery model and we will mail it to you.\u003c\/p\u003e\n\n\u003cdiv class=\"knh-box2\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003e\u003cstrong style=\"color:#0e1b4d;\"\u003egPV and gBat, said honestly.\u003c\/strong\u003e The fuse links we fit are \u003cstrong\u003egPV\u003c\/strong\u003e, tested to IEC 60269-6 on photovoltaic sources. The type tested on battery circuits is \u003cstrong\u003egBat\u003c\/strong\u003e, IEC 60269-7, designed for higher prospective short-circuit currents and longer L\/R time constants. On a 51.2V bank a 1000V gPV works at roughly 5% of its rated voltage, so in very conservative conditions, and 20kA is far above what a 48V bank can deliver. It is not, however, the type formally tested for batteries, and we are not going to sell it to you as something it is not. If the specification calls for a gBat, write to us: we order it to project.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eHow to pick the size\u003c\/h2\u003e\n\u003cp\u003eCount the number of battery inputs on the inverter, not just the kW: inverters up to roughly 12kW have one positive and one negative, those from 14kW upwards almost always have two and need two pairs of cables. The cable size shown is the one the manuals prescribe for that current.\u003c\/p\u003e\n\u003cp class=\"knh-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"knh-sc\"\u003e\n\u003ctable class=\"knh-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003eInverter size\u003c\/th\u003e\u003cth\u003eTypical battery current\u003c\/th\u003e\u003cth\u003eBattery inputs\u003c\/th\u003e\u003cth\u003eCable size\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e5-6kW\u003c\/td\u003e\u003ctd\u003eup to 135A\u003c\/td\u003e\u003ctd\u003e1\u003c\/td\u003e\u003ctd\u003e50mm\u0026sup2;\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e8kW\u003c\/td\u003e\u003ctd\u003eabout 190A\u003c\/td\u003e\u003ctd\u003e1\u003c\/td\u003e\u003ctd\u003e70mm\u0026sup2;\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e10kW\u003c\/td\u003e\u003ctd\u003eabout 210A\u003c\/td\u003e\u003ctd\u003e1\u003c\/td\u003e\u003ctd\u003e70mm\u0026sup2;\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e12kW\u003c\/td\u003e\u003ctd\u003eabout 240A\u003c\/td\u003e\u003ctd\u003e1\u003c\/td\u003e\u003ctd\u003e95mm\u0026sup2;\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e14-16kW\u003c\/td\u003e\u003ctd\u003e260A to 300A\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003ctd\u003e2\u0026times;50mm\u0026sup2;\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e18-20kW\u003c\/td\u003e\u003ctd\u003e330A to 350A\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003ctd\u003e2\u0026times;70mm\u0026sup2;\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eMEGA, Class T or NH: which fuse to choose\u003c\/h2\u003e\n\u003cp\u003eThe same kit exists in three versions. This is the NH one.\u003c\/p\u003e\n\u003cp class=\"knh-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"knh-sc\"\u003e\n\u003ctable class=\"knh-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003e\u0026nbsp;\u003c\/th\u003e\u003cth\u003eVictron MEGA 80V\u003c\/th\u003e\u003cth\u003eClass T\u003c\/th\u003e\u003cth\u003eNH gPV 1000V DC\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"knh-lab\"\u003eRated DC voltage\u003c\/td\u003e\u003ctd\u003e80V\u003c\/td\u003e\u003ctd\u003e125V fuse \/ 160V holder\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"knh-g\"\u003e1000V\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"knh-lab\"\u003eDC interrupting rating\u003c\/td\u003e\u003ctd\u003enot declared by the manufacturer\u003c\/td\u003e\u003ctd\u003e20,000A\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"knh-g\"\u003e20kA\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"knh-lab\"\u003eConnection\u003c\/td\u003e\u003ctd\u003edirect M8 bolt, 50.8mm centres\u003c\/td\u003e\u003ctd\u003e3\/8\u0026quot; studs (225-400A) or M8 (110-200A)\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"knh-g\"\u003eknife contacts: the cable lands on the base, not on the fuse\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"knh-lab\"\u003eBusbar\u003c\/td\u003e\u003ctd\u003eVictron Lynx Distributor, 4 positions with LEDs\u003c\/td\u003e\u003ctd\u003eVictron Lynx Class-T Power In, 2 positions\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"knh-g\"\u003eunfused Victron Lynx Power In plus separate NH bases\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"knh-lab\"\u003eMaximum cable size\u003c\/td\u003e\u003ctd\u003elimited by the M8 stud\u003c\/td\u003e\u003ctd\u003eup to 120mm\u0026sup2; on the M10 busbar\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"knh-g\"\u003eup to 300mm\u0026sup2; with the PK3 base\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"knh-lab\"\u003eKit price\u003c\/td\u003e\u003ctd\u003e19.80\u0026euro; to 568.52\u0026euro;\u003c\/td\u003e\u003ctd\u003e156.51\u0026euro; to 986.00\u0026euro;\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"knh-g\"\u003e186.86\u0026euro; to 1,934.26\u0026euro;\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"knh-lab\"\u003eWhen to choose it\u003c\/td\u003e\u003ctd\u003eresidential and small commercial on the Lynx busbar\u003c\/td\u003e\u003ctd\u003elarge LiFePO4 banks, marine and professional off-grid\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"knh-g\"\u003eindustrial switchboards, inspectable isolation, heavy cable\u003c\/span\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"knh-box2\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003e\u003cstrong style=\"color:#0e1b4d;\"\u003eTwo things worth knowing:\u003c\/strong\u003e the cables that run from each battery to the busbar are almost always supplied with the battery itself, so they are not included; if you do need them we will add them, just say so. The kit covers the DC side: the PV array DC board, the AC board and the earthing stay with the project.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eDelivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDelivery in \u003cstrong\u003e10-20 days\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eShipping within Italy and the European Union\u003c\/li\u003e\n\u003cli\u003eIf you are unsure which configuration you need, send us the inverter model and the battery model: we will tell you which kit to order\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Litio Store","offers":[{"title":"5-6kW - 1 ingresso batteria \/ 1 batteria","offer_id":55336655978833,"sku":"KIT-NH-06-1","price":186.86,"currency_code":"EUR","in_stock":true},{"title":"5-6kW - 1 ingresso batteria \/ 2 batterie","offer_id":55336656011601,"sku":"KIT-NH-06-2","price":727.2,"currency_code":"EUR","in_stock":true},{"title":"5-6kW - 1 ingresso batteria \/ 3 batterie","offer_id":55336656044369,"sku":"KIT-NH-06-3","price":914.06,"currency_code":"EUR","in_stock":true},{"title":"5-6kW - 1 ingresso batteria \/ 4 batterie","offer_id":55336656077137,"sku":"KIT-NH-06-4","price":1235.92,"currency_code":"EUR","in_stock":true},{"title":"8kW - 1 ingresso batteria \/ 1 batteria","offer_id":55336656109905,"sku":"KIT-NH-08-1","price":394.65,"currency_code":"EUR","in_stock":true},{"title":"8kW - 1 ingresso batteria \/ 2 batterie","offer_id":55336656142673,"sku":"KIT-NH-08-2","price":967.13,"currency_code":"EUR","in_stock":true},{"title":"8kW - 1 ingresso batteria \/ 3 batterie","offer_id":55336656175441,"sku":"KIT-NH-08-3","price":1153.99,"currency_code":"EUR","in_stock":true},{"title":"8kW - 1 ingresso batteria \/ 4 batterie","offer_id":55336656208209,"sku":"KIT-NH-08-4","price":1475.85,"currency_code":"EUR","in_stock":true},{"title":"10kW - 1 ingresso batteria \/ 1 batteria","offer_id":55336656240977,"sku":"KIT-NH-10-1","price":394.65,"currency_code":"EUR","in_stock":true},{"title":"10kW - 1 ingresso batteria \/ 2 batterie","offer_id":55336656273745,"sku":"KIT-NH-10-2","price":967.13,"currency_code":"EUR","in_stock":true},{"title":"10kW - 1 ingresso batteria \/ 3 batterie","offer_id":55336656306513,"sku":"KIT-NH-10-3","price":1153.99,"currency_code":"EUR","in_stock":true},{"title":"10kW - 1 ingresso batteria \/ 4 batterie","offer_id":55336656339281,"sku":"KIT-NH-10-4","price":1475.85,"currency_code":"EUR","in_stock":true},{"title":"12kW - 1 ingresso batteria \/ 1 batteria","offer_id":55336656372049,"sku":"KIT-NH-12-1","price":394.65,"currency_code":"EUR","in_stock":true},{"title":"12kW - 1 ingresso batteria \/ 2 batterie","offer_id":55336656404817,"sku":"KIT-NH-12-2","price":990.09,"currency_code":"EUR","in_stock":true},{"title":"12kW - 1 ingresso batteria \/ 3 batterie","offer_id":55336656437585,"sku":"KIT-NH-12-3","price":1176.95,"currency_code":"EUR","in_stock":true},{"title":"12kW - 1 ingresso batteria \/ 4 batterie","offer_id":55336656470353,"sku":"KIT-NH-12-4","price":1498.81,"currency_code":"EUR","in_stock":true},{"title":"14-16kW - 2 ingressi batteria \/ 1 batteria","offer_id":55336656503121,"sku":"KIT-NH-16-1","price":785.58,"currency_code":"EUR","in_stock":true},{"title":"14-16kW - 2 ingressi batteria \/ 2 batterie","offer_id":55336656535889,"sku":"KIT-NH-16-2","price":972.44,"currency_code":"EUR","in_stock":true},{"title":"14-16kW - 2 ingressi batteria \/ 3 batterie","offer_id":55336656568657,"sku":"KIT-NH-16-3","price":1294.3,"currency_code":"EUR","in_stock":true},{"title":"14-16kW - 2 ingressi batteria \/ 4 batterie","offer_id":55336656601425,"sku":"KIT-NH-16-4","price":1481.16,"currency_code":"EUR","in_stock":true},{"title":"18-20kW - 2 ingressi batteria \/ 1 batteria","offer_id":55336656634193,"sku":"KIT-NH-20-1","price":1238.68,"currency_code":"EUR","in_stock":true},{"title":"18-20kW - 2 ingressi batteria \/ 2 batterie","offer_id":55336656666961,"sku":"KIT-NH-20-2","price":1425.54,"currency_code":"EUR","in_stock":true},{"title":"18-20kW - 2 ingressi batteria \/ 3 batterie","offer_id":55336656699729,"sku":"KIT-NH-20-3","price":1747.4,"currency_code":"EUR","in_stock":true},{"title":"18-20kW - 2 ingressi batteria \/ 4 batterie","offer_id":55336656732497,"sku":"KIT-NH-20-4","price":1934.26,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/kit-protezioni-batteria-nh-1000v-cc-victron-lynx.png?v=1792151811"}],"url":"https:\/\/litio.store\/en\/collections\/italweber.oembed","provider":"litio.store","version":"1.0","type":"link"}