{"product_id":"fusibile-mersen-gbat-nh-1000v-cc-50a-250a-iec-60269-7-per-circuiti-batteria","title":"Mersen gBat NH fuse 1000V DC 50A-250A to IEC 60269-7 for battery circuits","description":"\u003cstyle\u003e\n.gbt-wrap{font-family:'Open Sans',sans-serif;font-size:16px;line-height:1.75;color:#222}\n.gbt-wrap h2{font-family:'Rajdhani',sans-serif;font-size:24px;color:#0e1b4d;margin:34px 0 14px;font-weight:700}\n.gbt-wrap p,.gbt-wrap li{font-size:16px}\n.gbt-wrap ul{padding-left:22px}\n.gbt-wrap li{margin-bottom:8px}\n.gbt-sc{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:14px 0 6px}\n.gbt-t{width:100%;border-collapse:collapse;font-family:'Tomorrow',sans-serif}\n.gbt-t.wide{min-width:700px}\n.gbt-t th{background:#0e1b4d;color:#fff;font-size:15px;padding:12px 14px;text-align:left;font-weight:700;white-space:nowrap}\n.gbt-t td{border:1px solid #ddd;font-size:15px;padding:12px 14px;background:#fff;vertical-align:top}\n.gbt-t tr:nth-child(even) td{background:#f7f8fa}\n.gbt-lab{background:#f0f0f0!important;color:#0e1b4d;font-weight:700}\n.gbt-g{color:#73aa02;font-weight:700}\n.gbt-box{background:#f4f7ec;border-left:5px solid #73aa02;padding:18px 20px;border-radius:6px;margin:22px 0}\n.gbt-box2{background:#fffbea;border:1px solid #ffd700;padding:18px 20px;border-radius:6px;margin:22px 0}\n.gbt-hint{display:none;font-size:14px;color:#777;margin:0 0 10px}\n@media (max-width:749px){\n.gbt-wrap h2{font-size:21px}\n.gbt-t th,.gbt-t td{padding:10px 12px;font-size:14px}\n.gbt-hint{display:block}\n.gbt-sc{border:1px solid #e3e6ec;border-radius:6px}\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"gbt-wrap\"\u003e\n\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:30px 26px;border-radius:8px;margin-bottom:26px;text-align:center;\"\u003e\n  \u003ch2 style=\"font-family:'Rajdhani',sans-serif;font-size:26px;margin:0 0 10px;color:#fff;font-weight:700;\"\u003eMersen gBat fuse 1000V DC\u003c\/h2\u003e\n  \u003cp style=\"font-size:17px;margin:0;color:#fff;opacity:.92;\"\u003eThe only NH fuse tested to the standard written for battery circuits\u003c\/p\u003e\n  \u003cp style=\"font-size:16px;margin:10px 0 0;color:#73aa02;font-weight:700;\"\u003eIEC 60269-7 \u0026middot; 100kA breaking capacity \u0026middot; 50A to 250A\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eThe \u003cstrong\u003egBat\u003c\/strong\u003e is the NH fuse link tested to \u003cstrong\u003eIEC 60269-7\u003c\/strong\u003e, the standard written specifically for battery circuits. It is not a photovoltaic fuse pressed into service: it is qualified on the prospective short-circuit currents a lithium bank can really deliver and on the L\/R time constants of those circuits, which are far longer than those of a solar string.\u003c\/p\u003e\n\n\u003cp\u003eThe difference reads in one line: \u003cspan class=\"gbt-g\"\u003e100kA\u003c\/span\u003e breaking capacity at 1000V DC on the NH1 and NH2 sizes, against the 20kA of an NH gPV of the same format. It is the protection you fit when the bank is large, the specification is serious, or both.\u003c\/p\u003e\n\n\u003ch2\u003eTwo contact versions, and the difference matters\u003c\/h2\u003e\n\u003cdiv class=\"gbt-box\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003eThe gBat exists with \u003cstrong\u003eplain blades\u003c\/strong\u003e and with \u003cstrong\u003ebolted blades\u003c\/strong\u003e. The plain-blade version is the classic NH: it clips into the contacts of a fuse base. The \u003cstrong\u003ebolted-blade version bolts straight\u003c\/strong\u003e onto the busbar or onto the terminals, with no base, and it is the one that solves the usual problem of compact storage boards, where an NH base simply does not fit. Tell us which one you need when you ask for a quote.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eCodes available at 1000V DC\u003c\/h2\u003e\n\u003cp class=\"gbt-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"gbt-sc\"\u003e\n\u003ctable class=\"gbt-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003eSize\u003c\/th\u003e\u003cth\u003eReference\u003c\/th\u003e\u003cth\u003eCode\u003c\/th\u003e\u003cth\u003eContact\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 50A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT50\u003c\/td\u003e\u003ctd\u003eT1068620\u003c\/td\u003e\u003ctd\u003eplain blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 50A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT50B\u003c\/td\u003e\u003ctd\u003eK1068612\u003c\/td\u003e\u003ctd\u003ebolted blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 63A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT63\u003c\/td\u003e\u003ctd\u003eV1068621\u003c\/td\u003e\u003ctd\u003eplain blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 63A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT63B\u003c\/td\u003e\u003ctd\u003eL1068613\u003c\/td\u003e\u003ctd\u003ebolted blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 80A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT80\u003c\/td\u003e\u003ctd\u003eW1068622\u003c\/td\u003e\u003ctd\u003eplain blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 80A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT80B\u003c\/td\u003e\u003ctd\u003eM1068614\u003c\/td\u003e\u003ctd\u003ebolted blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 100A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT100\u003c\/td\u003e\u003ctd\u003eX1068623\u003c\/td\u003e\u003ctd\u003eplain blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 100A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT100B\u003c\/td\u003e\u003ctd\u003eN1068615\u003c\/td\u003e\u003ctd\u003ebolted blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 125A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT125\u003c\/td\u003e\u003ctd\u003eY1068624\u003c\/td\u003e\u003ctd\u003eplain blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 125A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT125B\u003c\/td\u003e\u003ctd\u003eP1068616\u003c\/td\u003e\u003ctd\u003ebolted blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 160A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT160\u003c\/td\u003e\u003ctd\u003eZ1068625\u003c\/td\u003e\u003ctd\u003eplain blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH1 160A\u003c\/td\u003e\u003ctd\u003e10NH1GBAT160B\u003c\/td\u003e\u003ctd\u003eQ1068617\u003c\/td\u003e\u003ctd\u003ebolted blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH2 200A\u003c\/td\u003e\u003ctd\u003e10NH2GBAT200\u003c\/td\u003e\u003ctd\u003eA1068626\u003c\/td\u003e\u003ctd\u003eplain blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH2 200A\u003c\/td\u003e\u003ctd\u003e10NH2GBAT200B\u003c\/td\u003e\u003ctd\u003eR1068618\u003c\/td\u003e\u003ctd\u003ebolted blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH2 250A\u003c\/td\u003e\u003ctd\u003e10NH2GBAT250\u003c\/td\u003e\u003ctd\u003eB1068627\u003c\/td\u003e\u003ctd\u003eplain blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eNH2 250A\u003c\/td\u003e\u003ctd\u003e10NH2GBAT250B\u003c\/td\u003e\u003ctd\u003eS1068619\u003c\/td\u003e\u003ctd\u003ebolted blades\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:15px;color:#555;margin-top:4px;\"\u003eThere is also a \u003cstrong\u003e1500V DC\u003c\/strong\u003e range, sizes 1XL, 2XL and 3L, up to \u003cstrong\u003e500A\u003c\/strong\u003e and up to 200kA breaking capacity, for high-voltage storage systems. Ask us if you need it.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical data\u003c\/h2\u003e\n\u003cdiv class=\"gbt-sc\"\u003e\n\u003ctable class=\"gbt-t\"\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eStandard\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"gbt-g\"\u003eIEC 60269-7\u003c\/span\u003e (gBat) \u0026middot; UL 248-13\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eRated voltage\u003c\/td\u003e\u003ctd\u003e1000V DC\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eDC breaking capacity\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"gbt-g\"\u003e100kA\u003c\/span\u003e (NH1 and NH2, L\/R up to 3ms)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eMinimum breaking current\u003c\/td\u003e\u003ctd\u003e2\u0026times;In\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eRated currents\u003c\/td\u003e\u003ctd\u003e50A \u0026middot; 63A \u0026middot; 80A \u0026middot; 100A \u0026middot; 125A \u0026middot; 160A (NH1) \u0026middot; 200A \u0026middot; 250A (NH2)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eContact\u003c\/td\u003e\u003ctd\u003eplain blades or bolted blades for direct mounting\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eBlown-fuse indicator\u003c\/td\u003e\u003ctd\u003enot provided on this range\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003egBat, gPV or Class T\u003c\/h2\u003e\n\u003cp class=\"gbt-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"gbt-sc\"\u003e\n\u003ctable class=\"gbt-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003e\u0026nbsp;\u003c\/th\u003e\u003cth\u003eMersen gBat\u003c\/th\u003e\u003cth\u003eNH gPV 1000V DC\u003c\/th\u003e\u003cth\u003eClass T\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eStandard\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"gbt-g\"\u003eIEC 60269-7, tested on battery circuits\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003eIEC 60269-6, tested on photovoltaic sources\u003c\/td\u003e\u003ctd\u003eUL standard, born for use on battery banks\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eRated DC voltage\u003c\/td\u003e\u003ctd\u003e1000V (up to 1500V in the extended range)\u003c\/td\u003e\u003ctd\u003e1000V\u003c\/td\u003e\u003ctd\u003e125V\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eDC breaking capacity\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"gbt-g\"\u003e100kA\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003e20kA\u003c\/td\u003e\u003ctd\u003e20,000A\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eDoes it need a base?\u003c\/td\u003e\u003ctd\u003eno in the bolted-blade version, yes in the plain-blade one\u003c\/td\u003e\u003ctd\u003eyes, always\u003c\/td\u003e\u003ctd\u003eyes, a Class T holder or the Lynx Class-T\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"gbt-lab\"\u003eWhen to choose it\u003c\/td\u003e\u003ctd\u003ewhen the specification calls for it, or when the bank is large and you want protection qualified for batteries\u003c\/td\u003e\u003ctd\u003ewhen an NH is required and a gBat is not explicitly asked for\u003c\/td\u003e\u003ctd\u003e48V installations where the compact format matters more than the rated voltage\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eDelivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMade to order: lead time and availability confirmed with the quotation\u003c\/li\u003e\n\u003cli\u003eShipping within Italy and the European Union\u003c\/li\u003e\n\u003cli\u003eTell us the rated current, the contact version and the quantity: we will send you the quotation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cdiv class=\"gbt-box2\"\u003e\n\u003cp style=\"margin:0;font-size:16px;line-height:1.7;\"\u003e\u003cstrong style=\"color:#0e1b4d;\"\u003e\u0026#8505;\u0026#65039; Price on request:\u003c\/strong\u003e this item is made to order and the price depends on size, version and quantity. \u003cstrong\u003eContact us for a quotation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"Mersen","offers":[{"title":"NH1 50A - lame piatte","offer_id":55336217182545,"sku":"T1068620","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 50A - lame bullonate","offer_id":55336217215313,"sku":"K1068612","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 63A - lame piatte","offer_id":55336217248081,"sku":"V1068621","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 63A - lame bullonate","offer_id":55336217280849,"sku":"L1068613","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 80A - lame piatte","offer_id":55336217313617,"sku":"W1068622","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 80A - lame bullonate","offer_id":55336217346385,"sku":"M1068614","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 100A - lame piatte","offer_id":55336217379153,"sku":"X1068623","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 100A - lame bullonate","offer_id":55336217411921,"sku":"N1068615","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 125A - lame piatte","offer_id":55336217444689,"sku":"Y1068624","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 125A - lame bullonate","offer_id":55336217477457,"sku":"P1068616","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 160A - lame piatte","offer_id":55336217510225,"sku":"Z1068625","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH1 160A - lame bullonate","offer_id":55336217542993,"sku":"Q1068617","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH2 200A - lame piatte","offer_id":55336217575761,"sku":"A1068626","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH2 200A - lame bullonate","offer_id":55336217608529,"sku":"R1068618","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH2 250A - lame piatte","offer_id":55336217641297,"sku":"B1068627","price":0.01,"currency_code":"EUR","in_stock":true},{"title":"NH2 250A - lame bullonate","offer_id":55336217674065,"sku":"S1068619","price":0.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/fusibile-mersen-gbat-nh-1000v-cc-iec-60269-7.png?v=1792151811","url":"https:\/\/litio.store\/en\/products\/fusibile-mersen-gbat-nh-1000v-cc-50a-250a-iec-60269-7-per-circuiti-batteria","provider":"litio.store","version":"1.0","type":"link"}