{"product_id":"interruttore-magnetotermico-noark-100004-ex9bn-1p-curva-b-6-a-6-ka","title":"Noark 100004 Ex9BN Miniature Circuit Breaker 1P Curve B 6 A 6 kA","description":"\u003cstyle\u003e.lk{font-size:16px;line-height:1.7;color:#0e1b4d;max-width:920px}.lk h2{font-size:26px;line-height:1.3;margin:6px 0 14px;color:#0e1b4d;font-weight:700}.lk p{font-size:16px;line-height:1.7;margin:0 0 15px}.lk h3{font-size:20px;line-height:1.35;margin:28px 0 12px;color:#0e1b4d;font-weight:700;border-left:5px solid #73aa02;padding-left:12px}.lk .cs{display:flex;flex-wrap:wrap;gap:14px;margin:0 0 20px}.lk .c{flex:1 1 250px;min-width:240px;padding:15px 17px;border:1px solid #d7e0ea;border-top:4px solid #73aa02;border-radius:6px;background:#fff}.lk .c b{display:block;font-size:16px;color:#0e1b4d;margin-bottom:6px}.lk .c span{font-size:15px;line-height:1.6;color:#3b4557}.lk .tw{overflow-x:auto;margin:0 0 18px}.lk table{width:100%;border-collapse:collapse;border:1px solid #d7e0ea}.lk th{text-align:left;padding:11px 14px;font-size:15px;background:#0e1b4d;color:#fff}.lk td{padding:10px 14px;border-bottom:1px solid #d7e0ea;font-size:15px}.lk td:first-child{font-weight:600;color:#0e1b4d;width:46%}.lk tr:nth-child(even) td{background:#f7fafc}.lk a.d{display:flex;align-items:center;gap:14px;padding:13px 16px;border:1px solid #d7e0ea;border-radius:6px;background:#fff;text-decoration:none;color:#0e1b4d;margin:0 0 10px}.lk a.d i{flex:0 0 auto;display:inline-flex;align-items:center;justify-content:center;width:42px;height:42px;border-radius:6px;background:#73aa02;color:#fff;font-size:13px;font-weight:700;font-style:normal}.lk a.d span{font-size:16px;font-weight:600;line-height:1.4}.lk a.d small{display:block;font-size:14px;font-weight:400;color:#5a6b7a}.lk .bd{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 18px}.lk .b{display:inline-block;padding:7px 13px;border-radius:999px;background:#0e1b4d;color:#fff;font-size:14px;font-weight:600}.lk .b.g{background:#73aa02}\u003c\/style\u003e\u003cdiv class=\"litio-keno lk\"\u003e\u003cdiv class=\"litio-iva-notice\" style=\"margin:0 0 18px;padding:12px 15px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:14px;line-height:1.5;\"\u003e\u003cstrong style=\"font-weight:bold;color:#0e1b4d;\"\u003eVAT note\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBusinesses and non-Italian private customers: purchase with 22% VAT. The 10% rate is reserved for private customers resident in Italy \u0026mdash; \u003ca href=\"\/en\/pages\/iva-acquisti-aziendali\" style=\"color:#0e1b4d;text-decoration:underline;\"\u003efind out more\u003c\/a\u003e.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eForeign companies entitled to 0% VAT: please write to \u003ca href=\"mailto:info@litio.store\" style=\"color:#0e1b4d;text-decoration:underline;\"\u003einfo@litio.store\u003c\/a\u003e.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"bd\"\u003e\u003cspan class=\"b g\"\u003eDelivery in 10-20 days\u003c\/span\u003e\u003cspan class=\"b\"\u003eProtection device\u003c\/span\u003e\u003cspan class=\"b\"\u003eAC side\u003c\/span\u003e\u003cspan class=\"b\"\u003eNoark\u003c\/span\u003e\u003c\/div\u003e\u003ch2\u003eNoark 100004 Ex9BN Miniature Circuit Breaker 1P Curve B 6 A 6 kA\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eNoark 100004\u003c\/strong\u003e is a modular miniature circuit breaker of the \u003cstrong\u003eEx9BN\u003c\/strong\u003e series, in a \u003cstrong\u003esingle-pole\u003c\/strong\u003e version with a rated current of \u003cstrong\u003e6 A\u003c\/strong\u003e and \u003cstrong\u003etripping curve B\u003c\/strong\u003e. It takes up \u003cstrong\u003ea single DIN module\u003c\/strong\u003e (18 mm) and has a rated breaking capacity \u003cstrong\u003eIcn of 6 kA\u003c\/strong\u003e according to EN 60898.\u003c\/p\u003e\u003cp\u003eIt is installed in residential and commercial distribution boards and in photovoltaic combiner boxes to protect a single line against \u003cstrong\u003eoverload\u003c\/strong\u003e (bimetallic thermal release) and \u003cstrong\u003eshort circuit\u003c\/strong\u003e (instantaneous magnetic release), and to isolate the circuit during maintenance work. \u003cstrong\u003eCurve B\u003c\/strong\u003e, with magnetic tripping between 3 and 5 times the rated current, is the right choice for circuits without high inrush currents — lighting circuits, auxiliary and control circuits, supplies to electronic equipment — and for long lines where the minimum short-circuit current is low. The 6 A rating is typical of auxiliary circuits and lighting circuits.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cdiv class=\"cs\"\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eCurve B, 6 A\u003c\/b\u003e\u003cspan\u003eMagnetic tripping between 3 and 5 In: the right choice for lighting and auxiliary circuits and for long lines with low fault currents.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003e6 kA breaking capacity\u003c\/b\u003e\u003cspan\u003eIcn of 6 kA according to EN 60898 and Icu of 10 kA according to IEC 60947-2, suitable for residential and commercial installations.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eLimitation class 3\u003c\/b\u003e\u003cspan\u003eLimiting the specific let-through energy reduces the thermal and electrodynamic stress on downstream cables and devices.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eSingle-module width\u003c\/b\u003e\u003cspan\u003e18 mm wide and 72 mm flush-mounting depth: maximum device density in the board.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eExpandable with accessories\u003c\/b\u003e\u003cspan\u003eCompatible with auxiliary and signalling contacts, shunt trips, undervoltage and overvoltage releases and residual current blocks.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eDual protection\u003c\/b\u003e\u003cspan\u003eThe thermal release acts on prolonged overloads, the magnetic one opens instantaneously in the event of a short circuit.\u003c\/span\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cdiv class=\"tw\"\u003e\u003ctable\u003e\u003cthead\u003e\u003ctr\u003e\u003cth\u003eFeature\u003c\/th\u003e\u003cth\u003eValue\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003eProduct code\u003c\/td\u003e\u003ctd\u003e100004\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDevice type\u003c\/td\u003e\u003ctd\u003eModular miniature circuit breaker (MCB), Ex9BN series\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eSystem side\u003c\/td\u003e\u003ctd\u003eAlternating current (AC)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of poles \/ phases\u003c\/td\u003e\u003ctd\u003e1 pole\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNominal current\u003c\/td\u003e\u003ctd\u003e6 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eTripping curve\u003c\/td\u003e\u003ctd\u003eB\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking capacity (Icn, EN 60898)\u003c\/td\u003e\u003ctd\u003e6 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eBreaking capacity (Icu, IEC 60947-2)\u003c\/td\u003e\u003ctd\u003e10 kA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated voltage\u003c\/td\u003e\u003ctd\u003e230 V CA\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated frequency\u003c\/td\u003e\u003ctd\u003e50–60 Hz\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEnergy limiting class\u003c\/td\u003e\u003ctd\u003e3\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOvervoltage category\u003c\/td\u003e\u003ctd\u003eIII\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePollution degree\u003c\/td\u003e\u003ctd\u003e2\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eNumber of DIN modules\u003c\/td\u003e\u003ctd\u003e1 (18 mm)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eFlush-mounting depth\u003c\/td\u003e\u003ctd\u003e72 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003ePower dissipation\u003c\/td\u003e\u003ctd\u003e2.5 W\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eProtection rating\u003c\/td\u003e\u003ctd\u003eIP20\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMounting\u003c\/td\u003e\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDimensions\u003c\/td\u003e\u003ctd\u003e74 × 89 × 18 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWeight\u003c\/td\u003e\u003ctd\u003e0.12 kg\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStandards\u003c\/td\u003e\u003ctd\u003eEN 60898-1 e IEC 60947-2\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003cp style=\"font-size:16px;\"\u003eInstallation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.\u003c\/p\u003e\u003c\/div\u003e","brand":"Noark","offers":[{"title":"IVA 10%","offer_id":55014346162513,"sku":"100004-IVA10","price":21.82,"currency_code":"EUR","in_stock":true},{"title":"IVA 22%","offer_id":55014346195281,"sku":"100004-IVA22","price":24.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/100004.jpg?v=1789842192","url":"https:\/\/litio.store\/en\/products\/interruttore-magnetotermico-noark-100004-ex9bn-1p-curva-b-6-a-6-ka","provider":"litio.store","version":"1.0","type":"link"}