{"product_id":"ottimizzatore-di-potenza-solaredge-s1000-1gm4mbt-per-2-moduli-in-serie-impianti-commerciali","title":"SolarEdge S1000-1GM4MBT Power Optimizer for 2 Modules in Series, Commercial Systems","description":"\u003cstyle\u003e.lk{font-size:16px;line-height:1.7;color:#0e1b4d;max-width:920px}.lk h2{font-size:26px;line-height:1.3;margin:6px 0 14px;color:#0e1b4d;font-weight:700}.lk p{font-size:16px;line-height:1.7;margin:0 0 15px}.lk h3{font-size:20px;line-height:1.35;margin:28px 0 12px;color:#0e1b4d;font-weight:700;border-left:5px solid #73aa02;padding-left:12px}.lk .cs{display:flex;flex-wrap:wrap;gap:14px;margin:0 0 20px}.lk .c{flex:1 1 250px;min-width:240px;padding:15px 17px;border:1px solid #d7e0ea;border-top:4px solid #73aa02;border-radius:6px;background:#fff}.lk .c b{display:block;font-size:16px;color:#0e1b4d;margin-bottom:6px}.lk .c span{font-size:15px;line-height:1.6;color:#3b4557}.lk .tw{overflow-x:auto;margin:0 0 18px}.lk table{width:100%;border-collapse:collapse;border:1px solid #d7e0ea}.lk th{text-align:left;padding:11px 14px;font-size:15px;background:#0e1b4d;color:#fff}.lk td{padding:10px 14px;border-bottom:1px solid #d7e0ea;font-size:15px}.lk td:first-child{font-weight:600;color:#0e1b4d;width:46%}.lk tr:nth-child(even) td{background:#f7fafc}.lk a.d{display:flex;align-items:center;gap:14px;padding:13px 16px;border:1px solid #d7e0ea;border-radius:6px;background:#fff;text-decoration:none;color:#0e1b4d;margin:0 0 10px}.lk a.d i{flex:0 0 auto;display:inline-flex;align-items:center;justify-content:center;width:42px;height:42px;border-radius:6px;background:#73aa02;color:#fff;font-size:13px;font-weight:700;font-style:normal}.lk a.d span{font-size:16px;font-weight:600;line-height:1.4}.lk a.d small{display:block;font-size:14px;font-weight:400;color:#5a6b7a}.lk .bd{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 18px}.lk .b{display:inline-block;padding:7px 13px;border-radius:999px;background:#0e1b4d;color:#fff;font-size:14px;font-weight:600}.lk .b.g{background:#73aa02}\u003c\/style\u003e\u003cdiv class=\"litio-keno lk\"\u003e\u003cdiv class=\"litio-iva-notice\" style=\"margin:0 0 18px;padding:12px 15px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:14px;line-height:1.5;\"\u003e\u003cstrong style=\"font-weight:bold;color:#0e1b4d;\"\u003eVAT note\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eBusinesses and non-Italian private customers: purchase with 22% VAT. The 10% rate is reserved for private customers resident in Italy \u0026mdash; \u003ca href=\"\/en\/pages\/iva-acquisti-aziendali\" style=\"color:#0e1b4d;text-decoration:underline;\"\u003efind out more\u003c\/a\u003e.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eForeign companies entitled to 0% VAT: please write to \u003ca href=\"mailto:info@litio.store\" style=\"color:#0e1b4d;text-decoration:underline;\"\u003einfo@litio.store\u003c\/a\u003e.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"bd\"\u003e\u003cspan class=\"b g\"\u003eDelivery in 10-20 days\u003c\/span\u003e\u003cspan class=\"b\"\u003ePower optimizer\u003c\/span\u003e\u003cspan class=\"b\"\u003eDC side\u003c\/span\u003e\u003cspan class=\"b\"\u003eSolarEdge\u003c\/span\u003e\u003c\/div\u003e\u003ch2\u003eSolarEdge S1000-1GM4MBT Power Optimizer for 2 Modules in Series, Commercial Systems\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eSolarEdge S1000-1GM4MBT\u003c\/strong\u003e is a \u003cstrong\u003ecommercial S series power optimizer\u003c\/strong\u003e, designed to connect \u003cstrong\u003etwo photovoltaic modules in series\u003c\/strong\u003e to a single device: the number of optimizers, the installation time and the cost per kW are reduced, while keeping the \u003cstrong\u003eMPPT at module pair level\u003c\/strong\u003e typical of the SolarEdge architecture.\u003c\/p\u003e\u003cp\u003eIt is installed on the mounting structure, in series in the string connected to the \u003cstrong\u003eSolarEdge commercial three-phase inverters\u003c\/strong\u003e, with \u003cstrong\u003eMC4 connectors\u003c\/strong\u003e. It integrates \u003cstrong\u003eSafeDC™\u003c\/strong\u003e technology, which in the event of inverter shutdown or emergency intervention automatically reduces the voltage of each optimizer to about 1 V, and the \u003cstrong\u003eSolarEdge Sense Connect\u003c\/strong\u003e function for detecting connection faults. Monitoring is at module level through the SolarEdge platform; the \u003cstrong\u003eIP68 \/ NEMA 6P\u003c\/strong\u003e enclosure allows outdoor use.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cdiv class=\"cs\"\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eTwo modules per optimizer\u003c\/b\u003e\u003cspan\u003eA single device manages two panels connected in series: fewer units to install and faster wiring.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eEfficiency up to 99.5 %\u003c\/b\u003e\u003cspan\u003eMaximum efficiency 99.5 % and weighted efficiency 98.8 %.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eSafeDC™ safety\u003c\/b\u003e\u003cspan\u003eWith no grid or with the inverter off the voltage of each optimizer drops to about 1 V, removing the dangerous voltage on the string.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eSense Connect\u003c\/b\u003e\u003cspan\u003eContinuous monitoring of the connectors to identify wear and faulty contacts before they become a failure.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003eLong strings\u003c\/b\u003e\u003cspan\u003eUp to 30 optimizers per string (60 modules), with a maximum system voltage of 1000 V.\u003c\/span\u003e\u003c\/div\u003e\u003cdiv class=\"c\"\u003e\u003cb\u003e25-year warranty\u003c\/b\u003e\u003cspan\u003eIP68 \/ NEMA 6P enclosure for outdoor installation, with a 25-year manufacturer's warranty.\u003c\/span\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\u003cdiv class=\"tw\"\u003e\u003ctable\u003e\u003cthead\u003e\u003ctr\u003e\u003cth\u003eFeature\u003c\/th\u003e\u003cth\u003eValue\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003eProduct code\u003c\/td\u003e\u003ctd\u003eS1000-1GM4MBT\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModel\u003c\/td\u003e\u003ctd\u003eS1000-1GM4MBT\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eType\u003c\/td\u003e\u003ctd\u003eS series commercial power optimizer, for 2 modules in series\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectable modules\u003c\/td\u003e\u003ctd\u003e2 PV modules in series\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eRated DC input power\u003c\/td\u003e\u003ctd\u003e1050 W\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMax input voltage\u003c\/td\u003e\u003ctd\u003e125 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMPPT voltage range\u003c\/td\u003e\u003ctd\u003e12.5–105 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eModule maximum short-circuit current\u003c\/td\u003e\u003ctd\u003e20 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMax output voltage\u003c\/td\u003e\u003ctd\u003e80 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMax output current\u003c\/td\u003e\u003ctd\u003e18 A\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eEfficiency\u003c\/td\u003e\u003ctd\u003e99.5 % maximum, 98.8 % weighted\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eStandby safety voltage\u003c\/td\u003e\u003ctd\u003e1 ± 0.1 V per optimizer (SafeDC™)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eCable length\u003c\/td\u003e\u003ctd\u003eInput 1.3 m (long cable version); output (+) 4.7 m \/ (–) 0.10 m\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eConnectors\u003c\/td\u003e\u003ctd\u003eMC4 (input and output)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eMax string length\u003c\/td\u003e\u003ctd\u003e30 optimizers (60 modules), max system voltage 1000 V\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eProtection rating\u003c\/td\u003e\u003ctd\u003eIP68 \/ NEMA 6P\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eOperating temperature\u003c\/td\u003e\u003ctd\u003eFrom -40 to +85 °C (derating above 65 °C)\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWarranty\u003c\/td\u003e\u003ctd\u003e25 years\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eDimensions\u003c\/td\u003e\u003ctd\u003e129 × 165 × 52 mm\u003c\/td\u003e\u003c\/tr\u003e\u003ctr\u003e\u003ctd\u003eWeight\u003c\/td\u003e\u003ctd\u003e1.06 kg\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003ch3\u003eDocumentation\u003c\/h3\u003e\u003ca class=\"d\" href=\"https:\/\/knowledge-center.solaredge.com\/sites\/kc\/files\/se-s-series-commercial-power-optimizer-datasheet-eng-row.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003ci\u003ePDF\u003c\/i\u003e\u003cspan\u003eDatasheet S1000-1GM4MBT\u003csmall\u003eOfficial manufacturer document\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cp style=\"font-size:16px;\"\u003eInstallation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.\u003c\/p\u003e\u003c\/div\u003e","brand":"SolarEdge","offers":[{"title":"IVA 10%","offer_id":55015119421777,"sku":"S1000-1GM4MBT-IVA10","price":90.49,"currency_code":"EUR","in_stock":true},{"title":"IVA 22%","offer_id":55015119454545,"sku":"S1000-1GM4MBT-IVA22","price":100.37,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/S1000-1GM4MBT.jpg?v=1789861664","url":"https:\/\/litio.store\/en\/products\/ottimizzatore-di-potenza-solaredge-s1000-1gm4mbt-per-2-moduli-in-serie-impianti-commerciali","provider":"litio.store","version":"1.0","type":"link"}