{"product_id":"portafusibili-class-t-110a-400a-160v-cc-con-prigionieri-per-cavi-di-potenza","title":"Class T fuse holder 110A-400A 160V DC with studs for heavy battery cable","description":"\u003cstyle\u003e\n.pft-wrap{font-family:'Open Sans',sans-serif;font-size:16px;line-height:1.75;color:#222}\n.pft-wrap h2{font-family:'Rajdhani',sans-serif;font-size:24px;color:#0e1b4d;margin:34px 0 14px;font-weight:700}\n.pft-wrap p,.pft-wrap li{font-size:16px}\n.pft-wrap ul{padding-left:22px}\n.pft-wrap li{margin-bottom:8px}\n.pft-sc{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:14px 0 6px}\n.pft-t{width:100%;border-collapse:collapse;font-family:'Tomorrow',sans-serif}\n.pft-t.wide{min-width:700px}\n.pft-t th{background:#0e1b4d;color:#fff;font-size:15px;padding:12px 14px;text-align:left;font-weight:700;white-space:nowrap}\n.pft-t td{border:1px solid #ddd;font-size:15px;padding:12px 14px;background:#fff;vertical-align:top}\n.pft-t tr:nth-child(even) td{background:#f7f8fa}\n.pft-lab{background:#f0f0f0!important;color:#0e1b4d;font-weight:700}\n.pft-g{color:#73aa02;font-weight:700}\n.pft-box{background:#f4f7ec;border-left:5px solid #73aa02;padding:18px 20px;border-radius:6px;margin:22px 0}\n.pft-box2{background:#fffbea;border:1px solid #ffd700;padding:18px 20px;border-radius:6px;margin:22px 0}\n.pft-hint{display:none;font-size:14px;color:#777;margin:0 0 10px}\n@media (max-width:749px){\n.pft-wrap h2{font-size:21px}\n.pft-t th,.pft-t td{padding:10px 12px;font-size:14px}\n.pft-hint{display:block}\n.pft-sc{border:1px solid #e3e6ec;border-radius:6px}\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"pft-wrap\"\u003e\n\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:30px 26px;border-radius:8px;margin-bottom:26px;text-align:center;\"\u003e\n  \u003ch2 style=\"font-family:'Rajdhani',sans-serif;font-size:26px;margin:0 0 10px;color:#fff;font-weight:700;\"\u003eClass T fuse holder\u003c\/h2\u003e\n  \u003cp style=\"font-size:17px;margin:0;color:#fff;opacity:.92;\"\u003eThe base the fuse needs, and where the battery cable actually lands\u003c\/p\u003e\n  \u003cp style=\"font-size:16px;margin:10px 0 0;color:#73aa02;font-weight:700;\"\u003e160V DC \u0026middot; two ranges, 110-200A and 225-400A \u0026middot; surface mount\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eA Class T fuse has two bolt holes and nothing else: on its own it connects to nothing. This holder is the part that carries it and that the power cable is bolted to. It mounts on a flat surface, keeps the fuse accessible for inspection, and is rated \u003cstrong\u003e160V DC\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cdiv class=\"pft-box2\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003e\u003cstrong\u003eCheck the stud size before you order.\u003c\/strong\u003e The \u003cstrong\u003e110-200A\u003c\/strong\u003e holder has \u003cstrong\u003eM6\u003c\/strong\u003e cable studs. That is fine up to about 35mm\u0026sup2;, but it is \u003cstrong\u003enot suitable for 50 and 70mm\u0026sup2; lugs\u003c\/strong\u003e: for those cross-sections use the 225-400A holder, or the Victron Lynx Class-T Power In with its M10 busbar. The \u003cstrong\u003efuse is not included\u003c\/strong\u003e in either case.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical data\u003c\/h2\u003e\n\n\u003cdiv class=\"pft-sc\"\u003e\n\u003ctable class=\"pft-t\"\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003eDC voltage rating\u003c\/td\u003e\u003ctd\u003e160V, both sizes\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003e110-200A holder\u003c\/td\u003e\u003ctd\u003efuse studs 8mm, cable studs M6, surface mount\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003e225-400A holder\u003c\/td\u003e\u003ctd\u003efuse studs 8mm, cable studs M8 (the maker also lists 3\/8\u0026quot; on some versions), 178\u0026times;51\u0026times;59mm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003eFuse included\u003c\/td\u003e\u003ctd\u003eno\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003eMounting\u003c\/td\u003e\u003ctd\u003esurface, on a flat panel\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhich one for your cable\u003c\/h2\u003e\n\n\u003cdiv class=\"pft-box\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003eWork backwards from the lug, not from the current. With \u003cstrong\u003e50 or 70mm\u0026sup2;\u003c\/strong\u003e battery cable the only sensible choice in this pair is the \u003cstrong\u003e225-400A\u003c\/strong\u003e holder. The smaller one is for secondary circuits and lighter cable. If you are building around a Lynx busbar anyway, the Victron Lynx Class-T Power In takes lugs up to 120mm\u0026sup2; and carries two fuses, which usually works out neater than two separate holders.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eHow it mounts\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003eFix the holder to a flat surface, leaving room to get a spanner on both studs.\u003c\/li\u003e\n\u003cli\u003eLand the power cable on the cable stud with a ring lug, torqued to the maker's figure.\u003c\/li\u003e\n\u003cli\u003eFit the fuse across the two fuse studs with the system isolated.\u003c\/li\u003e\n\u003cli\u003eKeep the cover on in service: the studs are live and uninsulated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMEGA, Class T or NH: which fuse to choose\u003c\/h2\u003e\n\u003cp\u003eThree fuse families are actually used on the DC side of a 48V battery system, and they are interchangeable neither mechanically nor in performance.\u003c\/p\u003e\n\u003cp class=\"pft-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"pft-sc\"\u003e\n\u003ctable class=\"pft-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003e\u0026nbsp;\u003c\/th\u003e\u003cth\u003eVictron MEGA 80V\u003c\/th\u003e\u003cth\u003eClass T\u003c\/th\u003e\u003cth\u003eNH gPV 1000V DC\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003eDC voltage rating\u003c\/td\u003e\u003ctd\u003e80V\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"pft-g\"\u003e125V fuse \/ 160V holder\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003e1000V\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003eDC interrupting rating\u003c\/td\u003e\u003ctd\u003enot published by the manufacturer\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"pft-g\"\u003e20,000A\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003e20kA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003eConnection\u003c\/td\u003e\u003ctd\u003edirect M8 bolt, 50.8mm hole centres\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"pft-g\"\u003e3\/8\" studs (225-400A) or M8 (110-200A)\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003eknife contacts: the cable lands on the \u003cstrong\u003ebase\u003c\/strong\u003e, never on the fuse\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003eWhere it mounts\u003c\/td\u003e\u003ctd\u003ealready built into the Victron Lynx Distributor, with a status LED per position\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"pft-g\"\u003eVictron Lynx Class-T Power In (2 positions, M10 busbar) or a stand-alone holder\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003eNH fuse base PK0\/PK1\/PK2\/PK3, screw-mounted on the panel\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"pft-lab\"\u003eWhen to pick it\u003c\/td\u003e\u003ctd\u003eresidential and light commercial systems built around a Lynx busbar: the most compact and the cheapest\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"pft-g\"\u003elarge LiFePO4 banks, where a published DC interrupting rating matters. The reference choice in marine and professional off-grid\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003eindustrial switchboards, inspectable isolation, cable up to 240mm\u0026sup2;\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eDelivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDelivered in \u003cstrong\u003e10-20 days\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eShipping across Italy and the European Union\u003c\/li\u003e\n\u003cli\u003eNot sure which size you need? Send us the maximum discharge current from your battery manual and the cable cross-section, and we will tell you\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Blue Sea Systems","offers":[{"title":"110-200A","offer_id":55331964485969,"sku":"BS-5007100","price":78.31,"currency_code":"EUR","in_stock":true},{"title":"225-400A","offer_id":55331964518737,"sku":"BS-5502100","price":110.81,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/portafusibili-class-t-225a-400a-160v-cc-blue-sea.png?v=1792151810","url":"https:\/\/litio.store\/en\/products\/portafusibili-class-t-110a-400a-160v-cc-con-prigionieri-per-cavi-di-potenza","provider":"litio.store","version":"1.0","type":"link"}