{"product_id":"pulsante-sgancio-incendio-spamel-op1-w01-a11-m","title":"SPAMEL OP1 surface-mounted manual fire release call point, 1NO+1NC, with hammer","description":"\u003cstyle\u003e.lk{font-size:16px;line-height:1.7;color:#0e1b4d;max-width:920px}.lk h2{font-size:26px;line-height:1.3;margin:6px 0 14px;color:#0e1b4d;font-weight:700}.lk p{font-size:16px;line-height:1.7;margin:0 0 15px}.lk h3{font-size:20px;line-height:1.35;margin:28px 0 12px;color:#0e1b4d;font-weight:700;border-left:5px solid #73aa02;padding-left:12px}.lk .cs{display:flex;flex-wrap:wrap;gap:14px;margin:0 0 20px}.lk .c{flex:1 1 250px;min-width:240px;padding:15px 17px;border:1px solid #d7e0ea;border-top:4px solid #73aa02;border-radius:6px;background:#fff}.lk .c b{display:block;font-size:16px;color:#0e1b4d;margin-bottom:6px}.lk .c span{font-size:15px;line-height:1.6;color:#3b4557}.lk .tw{overflow-x:auto;margin:0 0 18px}.lk table{width:100%;border-collapse:collapse;border:1px solid #d7e0ea}.lk th{text-align:left;padding:11px 14px;font-size:15px;background:#0e1b4d;color:#fff}.lk td{padding:10px 14px;border-bottom:1px solid #d7e0ea;font-size:15px}.lk td:first-child{font-weight:600;color:#0e1b4d;width:46%}.lk tr:nth-child(even) td{background:#f7fafc}.lk a.d{display:flex;align-items:center;gap:14px;padding:13px 16px;border:1px solid #d7e0ea;border-radius:6px;background:#fff;text-decoration:none;color:#0e1b4d;margin:0 0 10px}.lk a.d i{flex:0 0 auto;display:inline-flex;align-items:center;justify-content:center;width:42px;height:42px;border-radius:6px;background:#73aa02;color:#fff;font-size:14px;font-weight:700;font-style:normal}.lk a.d span{font-size:16px;font-weight:600;line-height:1.4}.lk a.d small{display:block;font-size:14px;font-weight:400;color:#5a6b7a}.lk .bd{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 18px}.lk .b{display:inline-block;padding:7px 13px;border-radius:999px;background:#0e1b4d;color:#fff;font-size:14px;font-weight:600}.lk .b.g{background:#73aa02}\u003c\/style\u003e\u003cdiv class=\"litio-keno lk\"\u003e \u003cdiv class=\"litio-iva-notice\" style=\"margin:0 0 18px;padding:12px 16px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:16px;line-height:1.6;\"\u003e\u003cspan\u003ePrices include \u003cstrong\u003e22% Italian VAT\u003c\/strong\u003e; the \u003cstrong\u003ereduced 10% rate\u003c\/strong\u003e covers only goods for photovoltaic and storage systems, with a customer declaration. \u003cstrong\u003eFrom abroad\u003c\/strong\u003e: choose 22% VAT, or for \u003cstrong\u003e0% VAT\u003c\/strong\u003e place the order by bank transfer without paying and we send you a proforma invoice.\u003c\/span\u003e\u003cbr\u003e\u003ca href=\"\/en\/pages\/iva-acquisti-aziendali\" style=\"display:inline-block;margin-top:10px;padding:9px 16px;border-radius:6px;background:#73aa02;color:#fff;font-size:15px;font-weight:700;text-decoration:none;\"\u003eHow VAT works \u0026rsaquo;\u003c\/a\u003e\u003c\/div\u003e \u003cdiv class=\"bd\"\u003e \u003cspan class=\"b g\"\u003eDelivery in 10-20 days\u003c\/span\u003e\u003cspan class=\"b\"\u003e1NO + 1NC\u003c\/span\u003e\u003cspan class=\"b\"\u003eIP65\u003c\/span\u003e\u003cspan class=\"b\"\u003eHammer included\u003c\/span\u003e\u003cspan class=\"b\"\u003ePN-EN 54-11\u003c\/span\u003e\u003cspan class=\"b\"\u003eSPAMEL\u003c\/span\u003e \u003c\/div\u003e \u003ch2\u003eSPAMEL OP1 surface-mounted manual fire release call point, 1NO+1NC, with hammer\u003c\/h2\u003e \u003cp\u003eThe \u003cstrong\u003eOP1\u003c\/strong\u003e is the call point that gets broken in a fire to bring the system to a safe state. It does not break the power itself: it provides \u003cstrong\u003etwo volt-free contacts\u003c\/strong\u003e, one normally open and one normally closed, which change over permanently the moment the glass is broken with the hammer fixed next to it.\u003c\/p\u003e\u003cp\u003eIn photovoltaics it sits in the \u003cstrong\u003etrip chain\u003c\/strong\u003e: the NC contact goes in series with the supply to the coil of the string firefighter switches or to the undervoltage release of the main breaker. The logic is \u003cstrong\u003efail-safe\u003c\/strong\u003e: breaking the glass removes the control voltage and the switches open by themselves, and the same happens if the control cable is cut. The remaining NO contact is used for signalling to the fire panel or to the monitoring system.\u003c\/p\u003e\u003ch3\u003eKey strengths\u003c\/h3\u003e \u003cdiv class=\"cs\"\u003e \u003cdiv class=\"c\"\u003e \u003cb\u003eFail-safe logic\u003c\/b\u003e\u003cspan\u003eBreaking the glass removes the control voltage: the array opens by itself.\u003c\/span\u003e \u003c\/div\u003e\u003cdiv class=\"c\"\u003e \u003cb\u003eTwo contacts\u003c\/b\u003e\u003cspan\u003eOne for the trip, one for signalling to the panel.\u003c\/span\u003e \u003c\/div\u003e\u003cdiv class=\"c\"\u003e \u003cb\u003eHammer supplied\u003c\/b\u003e\u003cspan\u003eFixed next to the call point, always at hand.\u003c\/span\u003e \u003c\/div\u003e\u003cdiv class=\"c\"\u003e \u003cb\u003eIP65\u003c\/b\u003e\u003cspan\u003eCan also be installed outdoors or in dusty environments.\u003c\/span\u003e \u003c\/div\u003e\u003cdiv class=\"c\"\u003e \u003cb\u003eNo accidental reset\u003c\/b\u003e\u003cspan\u003eRestoring it requires replacing the glass.\u003c\/span\u003e \u003c\/div\u003e\u003cdiv class=\"c\"\u003e \u003cb\u003ePN-EN 54-11\u003c\/b\u003e\u003cspan\u003eManual call point compliant with the product standard.\u003c\/span\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch3\u003eTechnical specifications\u003c\/h3\u003e \u003cdiv class=\"tw\"\u003e\u003ctable\u003e \u003cthead\u003e\u003ctr\u003e \u003cth\u003eFeature\u003c\/th\u003e \u003cth\u003eValue\u003c\/th\u003e \u003c\/tr\u003e\u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003eManufacturer\u003c\/td\u003e \u003ctd\u003eSPAMEL\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eProduct code\u003c\/td\u003e \u003ctd\u003e1088646 \/ OP1-W01-A\\11-M\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eType\u003c\/td\u003e \u003ctd\u003eSurface-mounted manual fire call point for the trip chain\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eContacts\u003c\/td\u003e \u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eActuation\u003c\/td\u003e \u003ctd\u003eGlass breaking with automatic release of the button (version A)\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eReset\u003c\/td\u003e \u003ctd\u003eReplacement of the spare glass (PPOZ-5701, 65 x 65 mm)\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eInsulation voltage\u003c\/td\u003e \u003ctd\u003eUi 500 V\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eRated current\u003c\/td\u003e \u003ctd\u003eIth 10 A\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eAC rating (AC-15)\u003c\/td\u003e \u003ctd\u003e2,5 A @ 230 V - 1,6 A @ 400\/500 V\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eDC rating (DC-13)\u003c\/td\u003e \u003ctd\u003e4 A @ 24 V - 1 A @ 110 V - 0,25 A @ 220 V\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eTerminal cross-section\u003c\/td\u003e \u003ctd\u003eSolid 2 x 1-2.5 mm2, flexible 2 x 0.75-1.5 mm2\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eProtection rating\u003c\/td\u003e \u003ctd\u003eIP65\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eMounting\u003c\/td\u003e \u003ctd\u003eSurface, wall mounted\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eMaterial\u003c\/td\u003e \u003ctd\u003ePlastic, red\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e \u003ctd\u003e113 x 113 x 52 mm\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e0,31 kg\u003c\/td\u003e \u003c\/tr\u003e\u003ctr\u003e \u003ctd\u003eCertifications\u003c\/td\u003e \u003ctd\u003ePN-EN 54-11, CE certificate 1438\/CPD\/0130, CNBOP-PIB approval\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e\u003c\/div\u003e \u003ch3\u003eDocumentation\u003c\/h3\u003e \u003ca class=\"d\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/SPAMEL-OP1-Scheda-tecnica.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003ci\u003ePDF\u003c\/i\u003e\u003cspan\u003eDatasheet\u003csmall\u003eTechnical data of the product — OP1-W01-A\\11-M\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"d\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/SPAMEL-OP1-Manuale.pdf\" target=\"_blank\" rel=\"noopener\"\u003e\u003ci\u003ePDF\u003c\/i\u003e\u003cspan\u003eInstallation manual\u003csmall\u003eMounting and wiring instructions — OP1-W01-A\\11-M\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e \u003cp style=\"font-size:16px;\"\u003eWire the call point so that the NC contact interrupts the supply to the coil that must be de-energised: the trip then happens even if the control cable fails or is cut. After an activation the glass must be replaced; the spare part code is PPOZ-5701.\u003c\/p\u003e \u003c\/div\u003e","brand":"SPAMEL","offers":[{"title":"IVA 10%","offer_id":55149163675985,"sku":"1088646\/OP1-W01-A11-M-IVA10","price":46.76,"currency_code":"EUR","in_stock":true},{"title":"IVA 22%","offer_id":55149163708753,"sku":"1088646\/OP1-W01-A11-M-IVA22","price":51.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/pulsante-sgancio-incendio-spamel-op1-w01-a11-m.jpg?v=1790885140","url":"https:\/\/litio.store\/en\/products\/pulsante-sgancio-incendio-spamel-op1-w01-a11-m","provider":"litio.store","version":"1.0","type":"link"}