{"product_id":"victron-energy-lynx-class-t-power-in-m10-busbar-1000a-con-2-posizioni-per-fusibili-class-t-225-400a","title":"Victron Energy Lynx Class-T Power In M10, 1000A busbar with two Class T fuse positions 225-400A","description":"\u003cstyle\u003e\n.lct-wrap{font-family:'Open Sans',sans-serif;font-size:16px;line-height:1.75;color:#222}\n.lct-wrap h2{font-family:'Rajdhani',sans-serif;font-size:24px;color:#0e1b4d;margin:34px 0 14px;font-weight:700}\n.lct-wrap p,.lct-wrap li{font-size:16px}\n.lct-wrap ul{padding-left:22px}\n.lct-wrap li{margin-bottom:8px}\n.lct-sc{width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:14px 0 6px}\n.lct-t{width:100%;border-collapse:collapse;font-family:'Tomorrow',sans-serif}\n.lct-t.wide{min-width:700px}\n.lct-t th{background:#0e1b4d;color:#fff;font-size:15px;padding:12px 14px;text-align:left;font-weight:700;white-space:nowrap}\n.lct-t td{border:1px solid #ddd;font-size:15px;padding:12px 14px;background:#fff;vertical-align:top}\n.lct-t tr:nth-child(even) td{background:#f7f8fa}\n.lct-lab{background:#f0f0f0!important;color:#0e1b4d;font-weight:700}\n.lct-g{color:#73aa02;font-weight:700}\n.lct-box{background:#f4f7ec;border-left:5px solid #73aa02;padding:18px 20px;border-radius:6px;margin:22px 0}\n.lct-box2{background:#fffbea;border:1px solid #ffd700;padding:18px 20px;border-radius:6px;margin:22px 0}\n.lct-hint{display:none;font-size:14px;color:#777;margin:0 0 10px}\n@media (max-width:749px){\n.lct-wrap h2{font-size:21px}\n.lct-t th,.lct-t td{padding:10px 12px;font-size:14px}\n.lct-hint{display:block}\n.lct-sc{border:1px solid #e3e6ec;border-radius:6px}\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"lct-wrap\"\u003e\n\n\u003cdiv style=\"background:linear-gradient(135deg,#0e1b4d,#1a2966);color:#fff;padding:30px 26px;border-radius:8px;margin-bottom:26px;text-align:center;\"\u003e\n  \u003ch2 style=\"font-family:'Rajdhani',sans-serif;font-size:26px;margin:0 0 10px;color:#fff;font-weight:700;\"\u003eLynx Class-T Power In\u003c\/h2\u003e\n  \u003cp style=\"font-size:17px;margin:0;color:#fff;opacity:.92;\"\u003eTwo Class T fuses on a 1000A busbar, inside the Lynx system\u003c\/p\u003e\n  \u003cp style=\"font-size:16px;margin:10px 0 0;color:#73aa02;font-weight:700;\"\u003e1000A DC busbar \u0026middot; 2 fuse positions \u0026middot; 9-60Vdc \u0026middot; lugs to 120mm\u0026sup2;\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cp\u003eThis is the module that brings Class T protection into a Victron Lynx distribution system. It carries \u003cstrong\u003etwo Class T fuses\u003c\/strong\u003e, one per battery string, on a tinned copper busbar rated \u003cstrong\u003e1000A DC\u003c\/strong\u003e continuous. Lynx modules bolt to each other to form one continuous positive and negative bar, so with three or more battery strings you simply add another module.\u003c\/p\u003e\n\n\u003cdiv class=\"lct-box2\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003e\u003cstrong\u003eOnly 225-400A fuses fit, and they are not included.\u003c\/strong\u003e The fuse studs are 3\/8\u0026quot; with 46.7mm centres, which is the large Class T format: the 110-200A sizes have an M8 hole at 42.86mm centres and will not go in. Victron does not stock the fuses, so order them with the module. MEGA fuses do not fit either: those belong in the Lynx Distributor.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eTechnical data\u003c\/h2\u003e\n\n\u003cdiv class=\"lct-sc\"\u003e\n\u003ctable class=\"lct-t\"\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003ePart number\u003c\/td\u003e\u003ctd\u003eLYN060404010 \u0026middot; EAN 8719076062967\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eClass T fuse positions\u003c\/td\u003e\u003ctd\u003e2, one per battery string\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eFuse sizes accepted\u003c\/td\u003e\u003ctd\u003e225A, 250A, 300A, 350A, 400A\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eVoltage range\u003c\/td\u003e\u003ctd\u003e9-60Vdc (12V, 24V, 48V systems)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eBusbar current\u003c\/td\u003e\u003ctd\u003e1000A DC continuous\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eMaximum through the fuses\u003c\/td\u003e\u003ctd\u003e800A (2\u0026times;400A)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eBusbar thread\u003c\/td\u003e\u003ctd\u003eM10, 8\u0026times;30mm tinned copper bar\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eFuse fixing\u003c\/td\u003e\u003ctd\u003e3\/8\u0026quot; studs, bolts and nuts marked black. On units with a serial starting HQ the fuse hardware is M10 and unmarked\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eLugs accepted\u003c\/td\u003e\u003ctd\u003eup to 120mm\u0026sup2; (4\/0 AWG), M10 hole, 33Nm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eEnclosure\u003c\/td\u003e\u003ctd\u003eABS, IP20, 279\u0026times;169\u0026times;97mm, 2.1kg\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eTemperature\u003c\/td\u003e\u003ctd\u003e\u0026minus;40\u0026divide;60\u0026deg;C, 95% humidity non-condensing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eFuses included\u003c\/td\u003e\u003ctd\u003eno\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eWhat it is for\u003c\/h2\u003e\n\n\u003cdiv class=\"lct-box\"\u003e\n\u003cp style=\"margin:0;font-size:16px;\"\u003eIt is the fused entry point of the DC bus: battery strings come in through the fuses, everything else hangs off the common busbar, and there is a system earthing point on board. Fuse each string individually rather than protecting the whole bank behind one fuse: that way a single battery fault does not take the bank down and you can see which string opened.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eFitting it\u003c\/h2\u003e\n\n\u003cul\u003e\n\u003cli\u003eBolt the module to the adjacent Lynx modules so the internal bars make one continuous run.\u003c\/li\u003e\n\u003cli\u003eLand the battery cables on the M10 busbar with ring lugs, torqued to 33Nm.\u003c\/li\u003e\n\u003cli\u003eFit one Class T fuse per string, with the system isolated.\u003c\/li\u003e\n\u003cli\u003eIf a fuse flange does not sit flat on the bar, rotate the fuse 180\u0026deg; about its long axis: the manual calls this out explicitly.\u003c\/li\u003e\n\u003cli\u003eConnect the DC system earthing point as the installation requires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eMEGA, Class T or NH: which fuse to choose\u003c\/h2\u003e\n\u003cp\u003eThree fuse families are actually used on the DC side of a 48V battery system, and they are interchangeable neither mechanically nor in performance.\u003c\/p\u003e\n\u003cp class=\"lct-hint\"\u003e\u0026#8596; swipe the table sideways\u003c\/p\u003e\n\u003cdiv class=\"lct-sc\"\u003e\n\u003ctable class=\"lct-t wide\"\u003e\n\u003ctr\u003e\u003cth\u003e\u0026nbsp;\u003c\/th\u003e\u003cth\u003eVictron MEGA 80V\u003c\/th\u003e\u003cth\u003eClass T\u003c\/th\u003e\u003cth\u003eNH gPV 1000V DC\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eDC voltage rating\u003c\/td\u003e\u003ctd\u003e80V\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"lct-g\"\u003e125V fuse \/ 160V holder\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003e1000V\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eDC interrupting rating\u003c\/td\u003e\u003ctd\u003enot published by the manufacturer\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"lct-g\"\u003e20,000A\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003e20kA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eConnection\u003c\/td\u003e\u003ctd\u003edirect M8 bolt, 50.8mm hole centres\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"lct-g\"\u003e3\/8\" studs (225-400A) or M8 (110-200A)\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003eknife contacts: the cable lands on the \u003cstrong\u003ebase\u003c\/strong\u003e, never on the fuse\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eWhere it mounts\u003c\/td\u003e\u003ctd\u003ealready built into the Victron Lynx Distributor, with a status LED per position\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"lct-g\"\u003eVictron Lynx Class-T Power In (2 positions, M10 busbar) or a stand-alone holder\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003eNH fuse base PK0\/PK1\/PK2\/PK3, screw-mounted on the panel\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd class=\"lct-lab\"\u003eWhen to pick it\u003c\/td\u003e\u003ctd\u003eresidential and light commercial systems built around a Lynx busbar: the most compact and the cheapest\u003c\/td\u003e\u003ctd\u003e\u003cspan class=\"lct-g\"\u003elarge LiFePO4 banks, where a published DC interrupting rating matters. The reference choice in marine and professional off-grid\u003c\/span\u003e\u003c\/td\u003e\u003ctd\u003eindustrial switchboards, inspectable isolation, cable up to 240mm\u0026sup2;\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003ch2\u003eDelivery\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDelivered in \u003cstrong\u003e10-20 days\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eShipping across Italy and the European Union\u003c\/li\u003e\n\u003cli\u003eNot sure which size you need? Send us the maximum discharge current from your battery manual and the cable cross-section, and we will tell you\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":55331961864529,"sku":"LYN060404010","price":162.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/victron-energy-lynx-class-t-power-in-m10.png?v=1792151810","url":"https:\/\/litio.store\/en\/products\/victron-energy-lynx-class-t-power-in-m10-busbar-1000a-con-2-posizioni-per-fusibili-class-t-225-400a","provider":"litio.store","version":"1.0","type":"link"}