{"product_id":"gateway-trifase-sigenergy-sigen-gateway-c120-6-120-kw-182-4-a-per-6-inverter","title":"Gateway Trifase Sigenergy Sigen Gateway C120-6 120 kW 182,4 A per 6 Inverter","description":"\u003cstyle\u003e.lk{font-size:16px;line-height:1.7;color:#0e1b4d;max-width:920px}.lk h2{font-size:26px;line-height:1.3;margin:6px 0 14px;color:#0e1b4d;font-weight:700}.lk p{font-size:16px;line-height:1.7;margin:0 0 15px}.lk h3{font-size:20px;line-height:1.35;margin:28px 0 12px;color:#0e1b4d;font-weight:700;border-left:5px solid #73aa02;padding-left:12px}.lk .cs{display:flex;flex-wrap:wrap;gap:14px;margin:0 0 20px}.lk .c{flex:1 1 250px;min-width:240px;padding:15px 17px;border:1px solid #d7e0ea;border-top:4px solid #73aa02;border-radius:6px;background:#fff}.lk .c b{display:block;font-size:16px;color:#0e1b4d;margin-bottom:6px}.lk .c span{font-size:15px;line-height:1.6;color:#3b4557}.lk .tw{overflow-x:auto;margin:0 0 18px}.lk table{width:100%;border-collapse:collapse;border:1px solid #d7e0ea}.lk th{text-align:left;padding:11px 14px;font-size:15px;background:#0e1b4d;color:#fff}.lk td{padding:10px 14px;border-bottom:1px solid #d7e0ea;font-size:15px}.lk td:first-child{font-weight:600;color:#0e1b4d;width:46%}.lk tr:nth-child(even) td{background:#f7fafc}.lk a.d{display:flex;align-items:center;gap:14px;padding:13px 16px;border:1px solid #d7e0ea;border-radius:6px;background:#fff;text-decoration:none;color:#0e1b4d;margin:0 0 10px}.lk a.d i{flex:0 0 auto;display:inline-flex;align-items:center;justify-content:center;width:42px;height:42px;border-radius:6px;background:#73aa02;color:#fff;font-size:13px;font-weight:700;font-style:normal}.lk a.d span{font-size:16px;font-weight:600;line-height:1.4}.lk a.d small{display:block;font-size:14px;font-weight:400;color:#5a6b7a}.lk .bd{display:flex;flex-wrap:wrap;gap:10px;margin:0 0 18px}.lk .b{display:inline-block;padding:7px 13px;border-radius:999px;background:#0e1b4d;color:#fff;font-size:14px;font-weight:600}.lk .b.g{background:#73aa02}\u003c\/style\u003e\u003cdiv class=\"litio-keno lk\"\u003e\n\u003cdiv class=\"litio-iva-notice\" style=\"margin:0 0 18px;padding:12px 15px;border-left:4px solid #73aa02;border-radius:4px;background:#f4f7fb;color:#0e1b4d;font-size:14px;line-height:1.5;\"\u003e\n\u003cstrong style=\"font-weight:bold;color:#0e1b4d;\"\u003eNota IVA\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eAziende e clienti privati esteri: acquisto con IVA 22%. L'IVA 10% è riservata ai soli privati residenti in Italia — \u003ca href=\"\/fr\/pages\/iva-acquisti-aziendali\" style=\"color:#0e1b4d;text-decoration:underline;\"\u003escopri di più\u003c\/a\u003e.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAziende estere con diritto a IVA 0%: scrivete a \u003ca href=\"mailto:info@litio.store\" style=\"color:#0e1b4d;text-decoration:underline;\"\u003einfo@litio.store\u003c\/a\u003e.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"bd\"\u003e\n\u003cspan class=\"b g\"\u003eConsegna in 10-20 giorni\u003c\/span\u003e\u003cspan class=\"b\"\u003eQuadro ATS\u003c\/span\u003e\u003cspan class=\"b\"\u003eLato CA\u003c\/span\u003e\u003cspan class=\"b\"\u003eSigenergy\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch2\u003eGateway Trifase Sigenergy Sigen Gateway C120-6 120 kW 182,4 A per 6 Inverter\u003c\/h2\u003e\n\u003cp\u003eIl \u003cstrong\u003eSigen Gateway C120-6\u003c\/strong\u003e è il quadro di commutazione e distribuzione \u003cstrong\u003etrifase da 120 kW\u003c\/strong\u003e della gamma commerciale e industriale Sigenergy. Si colloca fra il punto di consegna e il quadro dei carichi di un impianto con fotovoltaico, accumulo ed eventuale gruppo elettrogeno, e gestisce automaticamente il passaggio fra le diverse sorgenti con \u003cstrong\u003einterruzione dichiarata di 0 ms sul lato carico\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMette a disposizione \u003cstrong\u003esei porte inverter da 45,6 A ciascuna\u003c\/strong\u003e, per collegare fino a sei SigenStor, e porte rete, backup e generatore da \u003cstrong\u003e182,4 A (120 kW)\u003c\/strong\u003e a 380\/400 V. Al suo interno integra \u003cstrong\u003einterruttori scatolati (MCCB) per rete, carichi di backup e generatore\/carichi gestiti\u003c\/strong\u003e, i \u003cstrong\u003etrasformatori di corrente\u003c\/strong\u003e per la misura su rete e generatore e \u003cstrong\u003etre posizioni modulari libere\u003c\/strong\u003e per ulteriori SigenStor o carichi. L'armadio, in \u003cstrong\u003ecategoria di sovratensione III\u003c\/strong\u003e, è previsto per \u003cstrong\u003einstallazione a pavimento\u003c\/strong\u003e in ambiente protetto e funziona da −30 °C a +55 °C fino a 4.000 m di altitudine.\u003c\/p\u003e\n\u003ch3\u003ePunti di forza\u003c\/h3\u003e\n\u003cdiv class=\"cs\"\u003e\n\u003cdiv class=\"c\"\u003e\n\u003cb\u003e120 kW trifase\u003c\/b\u003e\u003cspan\u003ePorte rete, backup e generatore da 182,4 A a 380\/400 V, per una potenza complessiva di 120 kW.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"c\"\u003e\n\u003cb\u003eSei porte inverter\u003c\/b\u003e\u003cspan\u003eSei ingressi da 45,6 A ciascuno per il collegamento di più SigenStor in un'unica architettura.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"c\"\u003e\n\u003cb\u003eCommutazione in 0 ms\u003c\/b\u003e\u003cspan\u003eInterruzione dichiarata nulla sul lato carico nel passaggio fra rete, fotovoltaico, accumulo e gruppo elettrogeno.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"c\"\u003e\n\u003cb\u003eInterruttori scatolati integrati\u003c\/b\u003e\u003cspan\u003eMCCB per la rete, i carichi di backup e il generatore\/carichi gestiti, con trasformatori di corrente per la misura.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"c\"\u003e\n\u003cb\u003eTre posizioni modulari di riserva\u003c\/b\u003e\u003cspan\u003eTre posti interruttore liberi per collegare ulteriori SigenStor o altri carichi in un secondo momento.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"c\"\u003e\n\u003cb\u003eInstallazione a pavimento\u003c\/b\u003e\u003cspan\u003eArmadio da pavimento in categoria di sovratensione III, raffreddamento a convezione naturale, da −30 °C a +55 °C.\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifiche tecniche\u003c\/h3\u003e\n\u003cdiv class=\"tw\"\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCaratteristica\u003c\/th\u003e\n\u003cth\u003eValore\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCodice prodotto\u003c\/td\u003e\n\u003ctd\u003e11110009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di quadro\u003c\/td\u003e\n\u003ctd\u003eGateway di commutazione e distribuzione trifase commerciale\/industriale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLato impianto\u003c\/td\u003e\n\u003ctd\u003eCA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensione nominale\u003c\/td\u003e\n\u003ctd\u003e380\/400 V, trifase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequenza nominale\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumero di fasi\u003c\/td\u003e\n\u003ctd\u003e3 fasi + neutro + terra\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotenza nominale CA\u003c\/td\u003e\n\u003ctd\u003e120 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente lato rete\u003c\/td\u003e\n\u003ctd\u003e182,4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente porta di backup\u003c\/td\u003e\n\u003ctd\u003e182,4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorta generatore\u003c\/td\u003e\n\u003ctd\u003e380\/400 V – 182,4 A – 120 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePorte inverter\u003c\/td\u003e\n\u003ctd\u003e6 da 45,6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosizioni interruttore di riserva\u003c\/td\u003e\n\u003ctd\u003e3, per ulteriori SigenStor o carichi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo di commutazione\u003c\/td\u003e\n\u003ctd\u003e0 ms sul lato carico\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterruttori di protezione\u003c\/td\u003e\n\u003ctd\u003eInterruttori scatolati (MCCB) per rete, carichi di backup e generatore\/carichi gestiti\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMisura di corrente\u003c\/td\u003e\n\u003ctd\u003eTrasformatori di corrente su rete e generatore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrado di protezione\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategoria di sovratensione\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRaffreddamento\u003c\/td\u003e\n\u003ctd\u003eConvezione naturale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallazione\u003c\/td\u003e\n\u003ctd\u003eA pavimento\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura di funzionamento\u003c\/td\u003e\n\u003ctd\u003eda −30 °C a +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUmidità relativa\u003c\/td\u003e\n\u003ctd\u003edallo 0% al 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitudine massima\u003c\/td\u003e\n\u003ctd\u003e4.000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComunicazione\u003c\/td\u003e\n\u003ctd\u003eFast Ethernet, RS485, contatto pulito\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensioni\u003c\/td\u003e\n\u003ctd\u003e110 × 850 × 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e74,0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eDocumentazione\u003c\/h3\u003e\n\u003ca class=\"d\" href=\"https:\/\/www.sigenergy.com\/en\/support\/files\/1155\" target=\"_blank\" rel=\"noopener\"\u003e\u003ci\u003ePDF\u003c\/i\u003e\u003cspan\u003eScheda tecnica\u003csmall\u003eDocumento ufficiale del produttore\u003c\/small\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cp style=\"font-size:16px;\"\u003eL'installazione e il collegamento devono essere eseguiti da personale qualificato secondo le norme CEI vigenti e il progetto elettrico dell'impianto.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Sigenergy","offers":[{"title":"IVA 10%","offer_id":55014352814417,"sku":"11110009-IVA10","price":4876.37,"currency_code":"EUR","in_stock":true},{"title":"IVA 22%","offer_id":55014352847185,"sku":"11110009-IVA22","price":5408.34,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2510\/0896\/files\/11110009.jpg?v=1789842527","url":"https:\/\/litio.store\/fr\/products\/gateway-trifase-sigenergy-sigen-gateway-c120-6-120-kw-182-4-a-per-6-inverter","provider":"litio.store","version":"1.0","type":"link"}