Businesses and non-Italian private customers: purchase with 22% VAT. The 10% rate is reserved for private customers resident in Italy — find out more.
Foreign companies entitled to 0% VAT: please write to info@litio.store.
Deye SUN-SMART-CT01 Wireless Energy Meter LoRa/RS485
The SUN-SMART-CT01 is Deye's DIN-rail energy meter that measures grid exchange in single-phase or three-phase and reports it to the inverter over LoRa, so no cable has to be run from the main board to the inverter. A wired RS485 connection is available as an alternative.
It is the component that makes zero export, self-consumption control and load management reliable: it measures voltage, current, power and frequency with ±0.1 V, ±0.01 A and ±1 W accuracy, using external CTs with 50 mA output. It works with the SUN-SMART-TX01 transmitter fitted on the Deye hybrid inverter and sits alongside the SUN-SMART-SWITCH01P3 smart switches, SUN-SMART-PLUG01P1-F plugs and SUN-EVSE wallboxes of the same family.
Key features
Technical specifications
| Feature | Value |
|---|---|
| Product code | SUN-SMART-CT01 |
| Type | Wireless energy meter with external CTs |
| Rated voltage | 85–300 V AC (L-N) |
| Wiring | Single-phase L1/N or three-phase L1/L2/L3/N |
| Rated frequency | 50 Hz (45–55 Hz) / 60 Hz (55–65 Hz) |
| CT output | 50 mA |
| Self-consumption | ≤2 W |
| Measuring accuracy | ±0.1 V, ±0.01 A, ±1 W, ±0.01 Hz |
| Communication | LoRa and RS485 |
| LoRa frequency | 863–870 MHz |
| Radio range | approx. 200 m barrier-free |
| Mounting | DIN rail |
| Ingress protection | IP20 |
| Operating temperature | -40 to +60 °C |
| Humidity | 0–75% |
| Altitude | ≤4000 m |
| Dimensions | 53 × 96 × 64 mm |
| Weight | 0.15 kg |
| Standard | IEC/EN 61010-1 |
| Warranty | 5 years |
Documentation
PDFManuale SUN-SMART-CT01Official manufacturer documentPDFDatasheet Wireless Energy Management SystemOfficial manufacturer documentPDFCommissioning Steps of the Smart DevicesOfficial manufacturer documentInstallation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.