Delivery in 10-20 daysATS switchgearAC sideLitio Store

Single-Phase ATS Switchgear 16 A for Huawei SUN2000 L1 Hybrid Inverter

Single-phase ATS (Automatic Transfer Switch) switchgear for photovoltaic systems with storage, designed for the single-phase hybrid inverters of the L1 series (Huawei SUN2000-2KTL…3.68KTL-L1). In the event of a grid failure it automatically switches the supply of the priority loads over to the backup output of the inverter, powered by the battery and the photovoltaic generator, and restores the grid connection when the grid returns.

Switching takes about 2 seconds by means of two interlocked contactors (25 A K1/K2) that guarantee double separation from the grid during island operation, as required by the connection rules. The backup circuit is protected by a B16 30 mA RCBO, for a maximum output current of 16 A (about 3.68 kW). The switchgear has an IP65 protection rating and is suitable for TN-S and TN-C-S systems.

Key features

Automatic switching in about 2 secondsWhen the grid fails the switchgear transfers the priority loads to the backup output of the inverter and returns them to the grid once it is restored, without any manual intervention.
Double separation from the gridThe two interlocked 25 A K1/K2 contactors guarantee separation on both conductors during island operation.
B16 30 mA RCBO protectionThe backup circuit is protected by a residual current circuit breaker with overcurrent protection, curve B, 16 A and a 30 mA residual current threshold.
Up to 16 A outputMaximum backup current 16 A at 230 V, equal to about 3.68 kW of priority loads that can be supplied when the grid is absent.
IP65 wall-mounted enclosureIP65 protection rating, wall mounting, 3 × M20 and 1 × M16 cable glands, terminals up to 6 mm² for inverter, grid, backup and communication.
Compatible with TN-S and TN-C-S systemsDesigned to operate on TN-S and TN-C-S distribution systems, with an operating temperature from -20 to +40 °C.

Technical specifications

FeatureValue
Switchboard typeATS switchgear for automatic grid/backup changeover
System sideAlternating current
Inverter compatibilityHuawei SUN2000-2KTL…3.68KTL-L1 single-phase hybrid inverters
Rated voltage230 V AC
Rated frequency50 Hz
Rated output current (backup)16 A
Maximum backup power3.68 kW
Number of poles / phasesSingle-phase, L + N
Switching timeApprox. 2 s
Switching contactors25 A K1/K2, interlocked (double separation from the grid)
Residual current breaker with overcurrent protection (RCBO)RCBO B16, 30 mA
Grid system typeTN-S / TN-C-S
Protection ratingIP65
Operating temperatureFrom -20 to +40 °C
Cable glands and terminals3 × M20 and 1 × M16; 6 mm² terminals for inverter, grid, backup and communication
Dimensions (W × H × D)319 × 384 × 144 mm
Weight3.1 kg

Documentation

PDFDatasheet SH-HWL1-SZROfficial manufacturer document

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.