Smart home kit server room and racks LoRaWAN Milesight, from 2 to 6 racks: rack temperature and humidity, water leaks, door opening and current on the PDU lines

Smart home kit server room and racks LoRaWAN Milesight, from 2 to 6 racks: rack temperature and humidity, water leaks, door opening and current on the PDU lines

Regular price €1,250.82
Regular price Sale price €1,250.82
Sale Sold out Excl. VAT — calculated in the cart
Version
Connectivity
Size
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

AVAILABILITY

Product available, quantity not tracked

Shipping

  • Italy: €13 on orders up to €150, free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
IT kit · server room and racks
Server room and racks kit, from 2 to 6 racks

Temperature and humidity at three heights on each rack, leaks under the air conditioner and under the raised floor, opening of the rack and room doors, current on the two PDU lines. Battery-powered sensors, LoRaWAN radio transmission independent of the data network, alarms on your smartphone.

Milesight devices Battery-powered sensors, no cables Radio separate from LAN and Wi-Fi Alarms on your smartphone
Customisable kits. This is one of the Milesight LoRaWAN kits in the Smart Home section. For different installations, tailor-made kits or custom automations, write to us from the contact section.
Several sizes. The figures, diagram and table on this page describe the «2 racks» size. The other sizes are selected above and are listed further down, under «Available sizes».
6 temperature pointsThree heights per rack, at the bottom, in the middle and at the top, with relative humidity.
Water leaksThree spot sensors with a buzzer and a 40 × 40 cm membrane under the raised floor.
4 doorsRacks and room: every opening is recorded with date and time and notified.
2 PDU linesCurrent on each line up to 100 A, with a split-core clamp fitted without disconnecting anything.

What it does

  • Six sensors measure temperature and humidity at the air intake, at three heights for each rack: you see the stratification, the hot spot at the top and the effect of an air conditioner that is not keeping up.
  • When the temperature or humidity thresholds are exceeded, a notification is sent to your smartphone, day and night.
  • Three floor leak sensors, under the air conditioner and at the low points, trigger with 0.5 mm of water and also sound on the spot. The sensitive membrane covers an area under the raised floor, where the condensate or chilled water pipe runs.
  • Four magnetic contacts detect the opening of the rack and room doors: every opening stays in the history with date and time, and those outside working hours generate a notification.
  • Two clamp meters read the current on the A and B lines of the PDUs: the load of each line, the imbalance between the two, a line that drops to zero.
  • History, charts and notifications can be consulted from a smartphone and from a PC, and the data can be sent to the monitoring system already in use.
For more racks or more rooms, floor cabinets distributed across the building, three-phase lines, additional probes at the exhaust or on the air conditioner return, if you want the alarms to be sent even when the company network is down and the 4G gateway is needed: tell us the characteristics of your room from the contact section and we will propose the right configuration together with the quotation.
Server room and racks kit Litio Store: installation diagram in a server room
1Compact indoor LoRaWAN gateway, on the wall or on the ceiling in the room, connected to the company network: it collects the data of the sensors and sends it to the cloud.
2Temperature and humidity sensor on the front of the rack, at three heights. Six in the kit.
3Water leak sensor on the floor, with a buzzer: under the air conditioner and at the low points. Three in the kit.
4Membrane leak sensor: sensitive sheet laid under the raised floor, transmitter body next to it.
5Magnetic contact on the rack doors and on the room door. Four in the kit.
6Clamp current meter on the PDU lines, in the switchboard. Two in the kit.

How it is installed

Gateway. In the room or in the adjacent room, on the wall or on the ceiling with the plate and two wall plugs, or resting on a shelf, outside the racks and away from metal masses. Connection to the network with an Ethernet cable or Wi-Fi, USB-C 5 V power supply, preferably on a UPS. It is an indoor device: IP30, operation from -20 to +50 °C.
Temperature sensors on the racks. On the intake side, three per rack: at the bottom, in the middle and at the top, where the temperature rises first. They are fastened with double-sided tape or with a cable tie to the upright or to the perforated door, without obstructing the air flow and not right up against the exhaust of a device. They measure from -30 to +70 °C with an accuracy of ±0.3 °C and humidity from 0 to 100%.
Leak sensors and membrane. The spot sensors rest on the floor, horizontal, where the water arrives first: under the air conditioner, next to the condensate drain, at the lowest point under the raised floor. The 400 × 400 mm membrane is laid on the slab under the raised floor with the adhesive side, on a flat and clean surface, without folds; the 1 m cable connects it to the transmitter body.
Doors and PDU lines. Magnetic contacts on the frame and on the leaf, with double-sided tape or screws, the sides with the notch facing each other and no more than 20 mm apart. Clamps of the current meters in the room switchboard, each one closed around the phase conductor of the line only, never around the whole cable with phase and neutral: 16 mm opening, 100 A rating. They are fitted without interrupting the line, but an electrician works in the switchboard.
Configuration. The temperature sensors, the leak sensors and the contacts are configured via NFC with a smartphone and the manufacturer's free app: reading intervals, thresholds, names of racks and doors. The current meters are configured from a PC with a USB-C cable and the manufacturer's free software. The gateway is configured from a browser.
Documentation included. Written installation guide with the position of the sensors on the racks, installation points of the leak sensors, mounting of the clamps and switch-on sequence, and initial configuration of thresholds and notifications based on the room indicated when ordering.

What's in the kit

Server room and racks kit Litio Store: the included devices
Qty Device What it is for
1 Compact indoor LoRaWAN gateway, Ethernet and Wi-Fi It collects the data of the sensors and sends it to the cloud. USB-C 5 V power supply.
6 Temperature and humidity sensor, IP67 Intake temperature at three heights per rack, with humidity.
3 Compact water leak sensor, IP67, with buzzer Water under the air conditioner and at the low points, 0.5 mm threshold.
1 Membrane leak sensor, 400 × 400 mm sheet Leaks over an area under the raised floor.
4 Magnetic contact for doors Opening of the rack and room doors.
2 Split-core clamp current meter, 100 A Current on the A and B lines of the PDUs.

Top quality Milesight devices with the manufacturer's warranty. Batteries included in the sensors; the gateway is powered at 5 V via USB-C, the current meters are powered from the conductor on which they are fitted.

Available sizes

The size is selected above, together with the version and the connectivity. The diagram, the photo and the table above show the «2 racks» size; with the other sizes only the quantities of the devices listed below change, the rest of the kit is identical.

  • 2 racks: 6 temperature and humidity sensors, 4 magnetic contacts, 2 clamp current meters up to 100 A
  • 4 racks: 12 temperature and humidity sensors, 6 magnetic contacts, 4 clamp current meters up to 100 A
  • 6 racks: 18 temperature and humidity sensors, 8 magnetic contacts, 6 clamp current meters up to 100 A

In the complete kit, the installation material linked to these devices (brackets, boxes, clips, cables, enclosures) follows the chosen size. For a different size, write to us from the contact section.

Available connectivity options

  • Customer network (Ethernet/Wi-Fi): 1 compact indoor LoRaWAN gateway
  • Integrated 4G: 1 compact LoRaWAN gateway with 4G. SIM not included; alarms independent of the company network
  • Large building: 1 semi-industrial LoRaWAN gateway. More range, IP65, PoE: for floor cabinets distributed across the building

In the complete kit, the material for the gateway (network cable, pole, PoE injector) changes accordingly. The SIM for the 4G versions is not included.

Choose the version

Devices only
The price updates above when you choose the version, the connectivity and the size.
  • The Milesight devices in the table
  • Installation guide and initial configuration
  • For those who already have a network cable and fastening material
Recommended
Complete kit with installation material
The price updates above when you choose the version, the connectivity and the size.
  • Everything in the basic version
  • 5 m Cat6 network cable to connect the gateway to the switch
  • Wall plugs, screws, double-sided tape, cable ties and adhesive cable guides in double supply, for sensors, contacts and gateway
  • Numbered labels for devices and lines, installation diagram

Before you order

The gateway goes on my network: what does it need?

An Ethernet port on the switch or the Wi-Fi, with a route out to the internet: it talks to the manufacturer's cloud or to your server. The sensors touch neither the LAN nor the Wi-Fi, they transmit to the gateway on a separate radio. If you prefer to keep the monitoring outside the company network, the version with a 4G gateway is available, which requires a data SIM (not included, any operator, traffic below 1 GB per month). It is chosen when ordering.

If the network goes down or there is no power in the room, do the alarms arrive?

The sensors are battery-powered and keep measuring; the leak sensors sound on the spot in any case. The notifications, however, go through the gateway: it must be powered on a UPS and, in the basic version, it needs the switch, the router and the internet line to be working. With the 4G version the notifications are sent even when the company network is down, as long as the gateway is powered.

Does it also cover the floor cabinets outside the room?

The compact gateway is designed for the room and the nearby rooms: the racks are metal masses and the sensors inside them must be kept on the door side. For floor cabinets distributed over several floors, thick walls or several buildings there is the «large building» variant, with a gateway of greater range, IP65 and able to be powered via PoE. One gateway handles hundreds of sensors.

Where do the temperature sensors go: front or back?

The kit is designed for the intake, at the front, at three heights: this is the temperature the devices receive, and it is the one the alarm is set on. If you also want the temperature rise, you can move one sensor per rack to the back, at the exhaust, or add more. The reading interval can be set from 1 minute; the default value is 10 minutes.

How are the PDU lines measured?

Each meter is a split-core clamp that closes around the phase conductor of the line that feeds the PDU, in the room switchboard: not around the whole supply cable, because phase and neutral together cancel each other out. It measures the current up to 100 A; the energy is an estimate calculated with the voltage and power factor set, not a billing-grade measurement. It is powered from the line itself and needs a load of at least 1.5 A; if the line drops it has a reserve of about 12 hours. For three-phase lines one clamp per phase is needed. Switchboard, PDUs and UPS are not included.

I have more than 2 racks or more rooms

Among the product options you will find the 2, 4 and 6 rack sizes: for each pair of racks, six temperature sensors, two door contacts and two current meters are added; the gateway and the platform stay the same. For more rooms, floor cabinets or different compositions, write to us from the contact section stating the number of racks, rooms and electrical lines: we will send you the composition and the quotation for the adapted kit.

Battery life

Temperature sensors and membrane sensor: up to 10 years declared, the former with one reading every 10 minutes. Compact leak sensors: over 5 years with a button cell. Magnetic contacts: about 5 years. Shorter intervals reduce the life. The charge level is visible in the app.

Where is the data consulted and are there any subscription fees?

On the manufacturer's app and portal, from a smartphone and a PC, with charts, thresholds and notifications; no fee for basic use. If there is an infrastructure monitoring system or a management software, the gateway can also send the data to that system (MQTT or HTTP): the configuration is included.

Is an electrician needed?

Only for the two current clamps, which are fitted in the switchboard around the conductors of the lines: nothing is disconnected, but the work is done with the switchboard open. Everything else is battery-powered and is fastened with double-sided tape, cable ties or two screws; the gateway is connected to a network port and to a USB-C power supply.

Degree of protection

The temperature sensors, the leak sensors and the body of the membrane sensor are IP67. The gateway and the current meters are IP30 and the magnetic contacts IP20: they are indoor devices, suitable for a server room, technical rooms and switchboards.

What is not included
  • Racks, PDUs, UPS, air conditioners and electrical switchboard: they are those of your room
  • The data SIM, in the version with a 4G gateway
  • The fitting of the current clamps in the switchboard
  • The PC with a USB-C cable to configure the current meters
  • In the "devices only" version: network cable, small parts and labels