AC Combiner Box 16A Three-Phase with Type 2 SPD and 300mA Type A RCD

AC Combiner Box 16A Three-Phase with Type 2 SPD and 300mA Type A RCD

Regular price €170.36
Regular price Sale price €170.36
Sale Sold out Excl. VAT — calculated in the cart
See the price with VAT

Price including VAT by delivery country

  • Italy22% €207.83
  • Germany19% €202.72
  • France20% €204.43
  • Austria20% €204.43
  • Belgium21% €206.13
  • Bulgaria20% €204.43
  • Croatia25% €212.95
  • Cyprus19% €202.72
  • Czech Republic21% €206.13
  • Denmark25% €212.95
  • Estonia24% €211.24
  • Finland25.5% €213.80
  • Greece24% €211.24
  • Hungary27% €216.35
  • Ireland23% €209.54
  • Latvia21% €206.13
  • Lithuania21% €206.13
  • Luxembourg17% €199.32
  • Malta18% €201.02
  • Netherlands21% €206.13
  • Poland23% €209.54
  • Portugal23% €209.54
  • Romania21% €206.13
  • Slovakia23% €209.54
  • Slovenia22% €207.83
  • Spain21% €206.13
  • Sweden25% €212.95

Shown prices exclude VAT. At checkout the rate of the delivery country applies. Businesses with a valid EU VAT number buy without VAT (reverse charge).

Free shipping to Italy Minimum order €400 excl. VAT
Configure your system in two minutes Pick the inverter and get the batteries it accepts, modules per string, switchboards, price per kWp and a cart ready to check out. Open the configurator →
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

Shipping

  • Italy: free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysCombiner boxAC sideLitio Store

AC Combiner Box 16A Three-Phase with Type 2 SPD and 300mA Type A RCD

Alternating current combiner box for three-phase photovoltaic systems, complete with residual current protection. It is installed on the AC side between the inverter output and the distribution board and brings together in a single enclosure all the protections required on the grid connection line: overcurrent protection, residual current protection and surge protection.

The equipment includes a 16A miniature circuit breaker against overloads and short circuits, a Type 2 surge protective device (class II) against transient overvoltages caused by indirect lightning strikes and switching operations, and a 300mA Type A residual current device. The 300mA sensitivity is the value typically used for protection against fire risks due to earth leakage currents; Type A ensures tripping even with pulsating unidirectional fault currents, the kind that can occur downstream of electronic equipment such as photovoltaic inverters.

Key features

Complete protection set16A miniature circuit breaker, 300mA Type A RCD and Type 2 surge arrester in a single pre-wired box.
Type A RCDTrips on alternating and pulsating unidirectional earth fault currents, suitable where power electronics are present.
300mA sensitivityA setting aimed at protection against fire risks caused by earth leakage.
Type 2 surge arresterLimits transient overvoltages coming from the grid, protecting the inverter and the downstream loads.
16A three-phase ratingSuitable for inverters with an indicative power of up to about 11kW on a 400V grid.
Tidy installation319 × 259 × 144 mm for 2.6 kg: a single wall-mounted enclosure instead of several devices scattered across the distribution board.

Technical specifications

FeatureValue
Switchboard typeAC combiner box for photovoltaic systems with residual current protection
System sideAlternating current (AC), between the inverter and the distribution board
Number of poles / phasesThree-phase (3L + N)
Nominal current16A
Indicative inverter powerUp to approx. 11kW (400V three-phase, 16A)
Surge protective device (type)Type 2 SPD (class II)
Miniature circuit breaker (MCB)Yes, 16A
Residual current device (RCD)Yes, 300mA Type A
Dedicated isolator switchNot present: isolation is provided by the miniature circuit breaker
Dimensions319 × 259 × 144 mm
Weight2.6 kg
Reference standards of the componentsEN 61643-11 (surge protective devices), EN 60898-1 (miniature circuit breakers), EN 61008-1 / EN 61009-1 (residual current devices)

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.