AC Combiner Box 20 A Three-Phase with Type 2 SPD and 300 mA Type A RCD

AC Combiner Box 20 A Three-Phase with Type 2 SPD and 300 mA Type A RCD

Regular price €170.48
Regular price Sale price €170.48
Sale Sold out Excl. VAT — calculated in the cart
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

AVAILABILITY

Product available, quantity not tracked

Shipping

  • Italy: €13 on orders up to €150, free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysCombiner boxAC sideLitio Store

AC Combiner Box 20 A Three-Phase with Type 2 SPD and 300 mA Type A RCD

Alternating current combiner box for three-phase photovoltaic systems, with integrated residual current protection. It must be installed on the AC side between the inverter output and the distribution board and provides, in a single pre-wired enclosure, all the protections for the grid connection line.

Inside there are a 20 A miniature circuit breaker, which protects the three-phase line against overload and short circuit and makes it possible to isolate the inverter, a Type 2 surge protective device (class II) for limiting transient overvoltages, and a 300 mA Type A residual current device, the sensitivity typically used for protection against fire risks caused by earth leakage currents. On a 400 V three-phase grid, 20 A corresponds approximately to inverters of up to about 13.8 kW.

Key features

Three protections in one boxOvercurrent, earth fault and transient overvoltages handled by a single pre-wired unit.
300 mA Type A RCDProtects against earth leakage currents, including the pulsating unidirectional ones generated by the inverter electronics.
Type 2 surge arresterThe class II SPD diverts to earth the transient overvoltages caused by indirect lightning strikes and switching operations.
20 A miniature circuit breakerProtects the three-phase line towards the main board and acts as the isolating device for the inverter.
For three-phase inverters20 A on a 400 V grid: suitable for inverters with an indicative power of up to about 13.8 kW.
Ready to install319 × 259 × 144 mm enclosure weighing 2.6 kg, with components already fitted and internally wired.

Technical specifications

FeatureValue
Switchboard typeAC combiner box for photovoltaic systems with residual current protection
System sideAlternating current (AC), between the inverter and the distribution board
Number of poles / phasesThree-phase (3L + N)
Nominal current20 A
Indicative inverter powerUp to approx. 13.8 kW (400 V three-phase, 20 A)
Surge protective device (type)Type 2 SPD (class II)
Miniature circuit breaker (MCB)Yes, 20 A
Residual current device (RCD)Yes, 300 mA Type A
Dedicated isolator switchNot present: isolation is provided by the miniature circuit breaker
Dimensions319 × 259 × 144 mm
Weight2.6 kg
Reference standards of the componentsEN 61643-11 (surge protective devices), EN 60898-1 (miniature circuit breakers), EN 61008-1 / EN 61009-1 (residual current devices)

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.