AC Combiner Box 40 A Three-Phase with Type 2 SPD

AC Combiner Box 40 A Three-Phase with Type 2 SPD

Regular price €144.03
Regular price Sale price €144.03
Sale Sold out
Tax included.
Scegli IVA
View full details
VAT note
Businesses and non-Italian private customers: purchase with 22% VAT. The 10% rate is reserved for private customers resident in Italy — find out more.
Foreign companies entitled to 0% VAT: please write to info@litio.store.
Delivery in 10-20 daysCombiner boxAC sideLitio Store

AC Combiner Box 40 A Three-Phase with Type 2 SPD

Alternating current combiner box for three-phase photovoltaic systems, designed for the highest power ratings in the range. It is installed on the AC side between the inverter output and the distribution board and gathers line protection and surge protection into a single enclosure.

The equipment includes a 40 A miniature circuit breaker for overload and short-circuit protection of the three-phase line, with an inverter isolation function, and a Type 2 surge protective device (class II) that limits transient surges of indirect atmospheric and switching origin. On a 400 V three-phase grid, 40 A corresponds roughly to inverters up to about 27.7 kW.

Key features

High rating40 A three-phase: suited to inverters with an indicative power output of up to about 27.7 kW.
40 A circuit breakerIt protects the grid connection cable against overloads and short circuits even with high operating currents.
Type 2 surge arresterIt limits the transient surges coming from the grid, reducing the risk of inverter failure.
Simplified installationThe box comes already assembled: there is no need to build a dedicated AC-side enclosure on site.
Inverter isolationIt allows the generation system to be quickly isolated from the grid.
Room for wiringEnclosure measuring 319 × 259 × 144 mm and weighing 2.2 kg, with an internal volume suited to conductors of a larger cross-section.

Technical specifications

FeatureValue
Switchboard typeAC combiner box for photovoltaic systems
System sideAlternating current (AC), between the inverter and the distribution board
Number of poles / phasesThree-phase (3L + N)
Nominal current40 A
Indicative inverter powerUp to approx. 27.7 kW (400 V three-phase, 40 A)
Surge protective device (type)Type 2 SPD (class II)
Miniature circuit breaker (MCB)Sì, 40 A
Residual current device (RCD)Not present
Dedicated isolator switchNot present: isolation is provided by the miniature circuit breaker
Dimensions319 × 259 × 144 mm
Weight2.2 kg
Reference standards of the componentsEN 61643-11 (surge protective devices), EN 60898-1 (miniature circuit breakers)

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.