Skip to product information
1 of 1

Litio Store

DC+AC Combiner Box 1000V with Type 2 SPD, 2 Strings 2 MPPT, 20A Three-Phase

DC+AC Combiner Box 1000V with Type 2 SPD, 2 Strings 2 MPPT, 20A Three-Phase

Regular price €416.00
Regular price Sale price €416.00
Sale Sold out Excl. VAT — calculated in the cart
See the price with VAT

Price including VAT by delivery country

  • Italy22% €507.52
  • Germany19% €495.04
  • France20% €499.20
  • Austria20% €499.20
  • Belgium21% €503.36
  • Bulgaria20% €499.20
  • Croatia25% €520.00
  • Cyprus19% €495.04
  • Czech Republic21% €503.36
  • Denmark25% €520.00
  • Estonia24% €515.84
  • Finland25.5% €522.08
  • Greece24% €515.84
  • Hungary27% €528.32
  • Ireland23% €511.68
  • Latvia21% €503.36
  • Lithuania21% €503.36
  • Luxembourg17% €486.72
  • Malta18% €490.88
  • Netherlands21% €503.36
  • Poland23% €511.68
  • Portugal23% €511.68
  • Romania21% €503.36
  • Slovakia23% €511.68
  • Slovenia22% €507.52
  • Spain21% €503.36
  • Sweden25% €520.00

Shown prices exclude VAT. At checkout the rate of the delivery country applies. Businesses with a valid EU VAT number buy without VAT (reverse charge).

Free shipping to Italy
Configure your system in two minutes Pick the inverter and get the batteries it accepts, modules per string, switchboards, price per kWp and a cart ready to check out. Open the configurator →
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.

Shipping

  • Italy: free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysCombiner boxDC+AC sideLitio Store

DC+AC Combiner Box 1000V with Type 2 SPD, 2 Strings 2 MPPT, 20A Three-Phase

Combined DC+AC combiner box for photovoltaic systems with residential size three-phase inverters. It manages 2 PV strings on 2 MPPT inputs and integrates in a single wall-mounted enclosure the surge protection of the DC side and the protection of the AC line.

On the DC side there is a Type 2 surge protective device for 1000V DC, which limits the surges induced by indirect lightning strikes and by grid switching, protecting the inverter inputs. On the AC side there are a Type 2 SPD and a 20A three-phase miniature circuit breaker, which protects and isolates the connection line between inverter and distribution board. This is the standard configuration for three-phase systems without a lightning protection system.

Key features

Standard configuration for three-phase systemsTwo strings, two MPPT and a 20A MCB: the most common combination on three-phase residential photovoltaic systems.
Type 2 SPD on DC and on ACProtection against induced and switching surges upstream and downstream of the inverter, on the two sides of the system.
2 strings on 2 independent MPPTEach string keeps its own maximum power point tracker, useful with roof pitches of different orientation or tilt.
20A three-phase MCBIt protects the AC line against overload and short circuit and allows it to be isolated during maintenance.
A single box for DC and ACIt reduces the number of wall enclosures, the cable runs and the installation time compared with two separate boxes.
Supplied assembled and wiredOnly the string and line connections remain to be made on site.

Technical specifications

FeatureValue
Switchboard typeCombined DC+AC combiner box for photovoltaic systems
System sideDirect current and alternating current
Number of PV strings2
MPPTs managed2
Maximum PV voltage1000V DC
DC surge protective device (SPD)Type 2, 1000V DC
AC surge protective device (SPD)Type 2
Miniature circuit breaker (MCB)20A, three-phase (3 poles)
Number of poles / phasesThree-phase AC side
Residual current device (RCD)Not present: to be provided upstream in the distribution board
Dimensions (W × H × D)319 × 384 × 144 mm
Weight3.7 kg
Reference standards of the componentsEN 61643-11 (AC SPDs), EN 61643-31 (PV SPDs), IEC/EN 60898-1 (MCB)

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.