DC+AC Combiner Box with Type 1+2 SPD on DC Side, 2 Strings 2 MPPT, 16A Three-Phase and 300mA RCD

DC+AC Combiner Box with Type 1+2 SPD on DC Side, 2 Strings 2 MPPT, 16A Three-Phase and 300mA RCD

Regular price €332.29
Regular price Sale price €332.29
Sale Sold out Excl. VAT — calculated in the cart
See the price with VAT

Price including VAT by delivery country

  • Italy22% €405.39
  • Germany19% €395.42
  • France20% €398.74
  • Austria20% €398.74
  • Belgium21% €402.07
  • Bulgaria20% €398.74
  • Croatia25% €415.36
  • Cyprus19% €395.42
  • Czech Republic21% €402.07
  • Denmark25% €415.36
  • Estonia24% €412.03
  • Finland25.5% €417.02
  • Greece24% €412.03
  • Hungary27% €422.00
  • Ireland23% €408.71
  • Latvia21% €402.07
  • Lithuania21% €402.07
  • Luxembourg17% €388.77
  • Malta18% €392.10
  • Netherlands21% €402.07
  • Poland23% €408.71
  • Portugal23% €408.71
  • Romania21% €402.07
  • Slovakia23% €408.71
  • Slovenia22% €405.39
  • Spain21% €402.07
  • Sweden25% €415.36

Shown prices exclude VAT. At checkout the rate of the delivery country applies. Businesses with a valid EU VAT number buy without VAT (reverse charge).

Free shipping to Italy Minimum order €400 excl. VAT
Configure your system in two minutes Pick the inverter and get the batteries it accepts, modules per string, switchboards, price per kWp and a cart ready to check out. Open the configurator →
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.

Shipping

  • Italy: free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysCombiner boxDC+AC sideLitio Store

DC+AC Combiner Box with Type 1+2 SPD on DC Side, 2 Strings 2 MPPT, 16A Three-Phase and 300mA RCD

Combined DC+AC combiner box for photovoltaic systems with three-phase inverters, intended for buildings fitted with a lightning protection system on the generator side. It manages 2 PV strings on 2 MPPT inputs.

The DC side is protected by a Type 1+2 surge protective device for 1000V DC, also able to discharge direct lightning current; the AC side by a Type 2 SPD, a 16A three-phase miniature circuit breaker and a 300mA Type A residual current circuit breaker. The 300mA threshold is typical of protection against electrically caused fires on the supply line, and not of protection against direct contact.

Key features

Type 1+2 SPD on the DC sideA combined arrester suitable for buildings with a lightning protection system, where the discharge of direct lightning current is required.
300mA Type A RCDHigh threshold residual current protection, aimed at protection against electrically caused fires on the AC line.
16A three-phase MCBIt protects and isolates the AC line between inverter and distribution board against overloads and short circuits.
2 strings on 2 MPPTThe strings remain separate up to the inverter, with independent maximum power point tracking for each one.
DC and AC protection in a single boxOne wall enclosure instead of two separate boxes, with the internal wiring already carried out.
String voltage up to 1000VCompatible with string inverters with a maximum input voltage of 1000V DC.

Technical specifications

FeatureValue
Switchboard typeCombined DC+AC combiner box with residual current protection
System sideDirect current and alternating current
Number of PV strings2
MPPTs managed2
Maximum PV voltage1000V DC
DC surge protective device (SPD)Type 1+2, 1000V DC
AC surge protective device (SPD)Type 2
Miniature circuit breaker (MCB)16A, three-phase (3 poles)
Residual current device (RCD)300mA, Type A
Number of poles / phasesThree-phase AC side
Dimensions (W × H × D)128 × 201 × 120 mm
Weight4.3 kg
Reference standards of the componentsEN 61643-11 (AC SPDs), EN 61643-31 (PV SPDs), IEC/EN 60898-1 (MCB), IEC/EN 61008-1 or 61009-1 (RCD)

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.