Built to order for commercial photovoltaic systems with eight independent strings.
Built to order for commercial photovoltaic systems with eight independent strings.
Litio Store 8/8 DC field combiner box designed to connect eight independent photovoltaic strings to the eight PV inputs of a multi-MPPT inverter, without external parallel connections. Each string is protected on both poles with gPV 25 A photovoltaic fuses.
Planned configuration
| Inputs / outputs | 8 string inputs / 8 independent outputs |
| Rated voltage | up to 1000 VDC |
| String protection | 8 bipolar protections with 16 10×38 fuse holders and 16 gPV 25 A fuses, 1000 VDC |
| Surge protection | Type 2 DC SPD coordinated with the eight circuits; Type 1+2 available if required by the project |
| Enclosure | IP66 wall-mounted enclosure, insulating material, cable glands, terminals and PE busbar |
| Wiring | internal wiring, circuit identification and safety labelling |
independent strings
No parallel connections in the panel: each output reaches the corresponding PV input of the inverter.
No parallel connections in the panel: each output reaches the corresponding PV input of the inverter.
Bipolar protection
gPV 25 A fuses on both the positive and negative poles of each string.
gPV 25 A fuses on both the positive and negative poles of each string.
Mandatory technical note. The panel is defined and assembled to order. Before production, the inverter wiring diagram, Voc at minimum temperature, string Isc, maximum current per input/MPPT, cable size and routing, maximum fuse rating allowed by the module, and the need for Type 1+2 SPD based on the LPS and lightning risk assessment must all be verified. Installation, testing and the declaration of conformity must be carried out by a qualified company. The image is an illustrative representation of the configuration.