Soluzione Solare Temmeter TM3 PT100 Class A Module Temperature Sensor
The Temmeter TM3 with PT100 probe by Soluzione Solare is the sensor that measures the cell temperature of the PV module, a figure that is essential for calculating the plant's Performance Ratio according to IEC 61724-1 and for distinguishing a drop in yield caused by overheating from an actual fault.
It is applied to the back of the PV module with the integrated 0.4 mm adhesive, suitable for bonding to tedlar and flat plastic surfaces: it goes over a non-peripheral cell and within 1.2 m of the Sunmeter it is connected to. The sensing element is a class A PT100 embedded in a white anti-shock plastic housing that is thermally neutral under direct irradiance; the output is analogue resistive and is converted into a digital Modbus signal by the Sunmeter pyranometer or by the data logger it is paired with.
Key features
Technical specifications
| Feature | Value |
|---|---|
| Product code | TM3-TEMMETER PT100 |
| Model | Soluzione Solare Temmeter – TM3 PT100 |
| Function | Measurement of the PV module temperature (cell temperature) |
| Sensor type | Class A PT100 platinum thermal resistor |
| Reference standards | IEC 60751 (class A), DIN 43760 (Kl. A) |
| Measuring range | −40 °C … +120 °C |
| Precision | ±0.25 °C |
| Accuracy | ±0.3 |
| Response time | < 5 s for changes ≥ 2 °C |
| Output | Analogue PT100 impedance variation (Δ ±0.3 °C); digital reading through the Sunmeter pyranometer or a data logger |
| Housing | White anti-shock plastic, thermally neutral under direct irradiance |
| Fixing | 0.4 mm adhesive, for bonding to tedlar and flat plastic surfaces |
| Probe dimensions | Ø 25 mm, average thickness 4.5 mm |
| Cable | 1.25 m, 2-pole, shielded, with outer insulation resistant to high temperature and UV |
| Connector | M8 2-pole IP67 or 3 loose pins (white-red): specify when ordering |
| Maximum distance from the pyranometer | 1.2 m |
| Weight | 0.03 kg |
Documentation
PDFDatasheetManufacturer technical dataPDFInstallation guideMounting and wiring best practicePDFEC declaration of conformitySoluzione Solare SrlInstallation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.