Businesses and non-Italian private customers: purchase with 22% VAT. The 10% rate is reserved for private customers resident in Italy — find out more.
Foreign companies entitled to 0% VAT: please write to info@litio.store.
Sigenergy Sigen Hybrid 110M1-HYB Hybrid Inverter 110 kW Three-Phase
The Sigen Hybrid 110M1-HYB is Sigenergy's 110 kW three-phase commercial and industrial (C&I) hybrid inverter in the HYB version, the only one in the range that supports on-grid and off-grid operation with load backup. It combines a photovoltaic inverter and a battery inverter and connects from 4 to 21 SigenStack BAT 12.0 modules through the M2-0.5C-BST / M2-1C-BST battery controllers, with charging and discharging power up to 121,000 W.
The photovoltaic side accepts up to 220,000 Wp across 8 MPPTs (2 strings per tracker, 40 A per MPPT, 160-1,000 V range, maximum DC voltage 1,100 V). Backup switchover takes 0 ms with peak power up to 150,000 W for 10 seconds, and the AC input accepts up to 160,000 VA. Maximum efficiency of 98.4%, IP66 and intelligent air cooling.
Key features
Technical specifications
| Feature | Value |
|---|---|
| Product code | 11010221 |
| Model | Sigen Hybrid 110M1-HYB |
| Rated AC power | 110.000 W |
| Max AC power | 121.000 VA |
| Recommended max PV power | 220.000 Wp |
| Max PV voltage | 1.100 V |
| Rated PV voltage | 600 V |
| Start-up voltage | 180 V |
| MPPT range | 160-1.000 V |
| Number of MPPTs | 8 |
| Strings per MPPT | 2 |
| Max current per MPPT | 40 A |
| Max short-circuit current per MPPT | 60 A |
| Compatible battery modules | SigenStack BAT 12.0, 4 to 21 modules (battery controller M2-0.5C-BST / M2-1C-BST) |
| Max charge/discharge power | 121.000 W |
| Max battery current | 180 A |
| Backup/EPS power | 150,000 W peak for 10 s, 0 ms switchover |
| Max AC input apparent power | 160.000 VA |
| Rated AC current | 159.4 A (at 400 V) |
| Max AC current | 183.8 A (at 380 / 400 V) |
| Grid phase | Three-phase |
| Grid voltage | 380 / 400 V, 3W+N+PE |
| Grid frequency | 50 / 60 Hz |
| Power factor | from 0.8 leading to 0.8 lagging |
| THDi harmonic distortion | < 3 % |
| Maximum efficiency | 98.4 % |
| Protection rating | IP66 |
| Cooling | Intelligent air cooling |
| Communication | Wi-Fi (WLAN), Ethernet (LAN), RS485, optional Sigen CommMod 4G/3G/2G |
| Protections | PV reverse polarity protection, insulation monitoring, residual current monitoring, arc fault circuit interrupter (AFCI), AC overcurrent/overvoltage/short-circuit protection, type II SPD on the DC and AC side, anti-islanding protection |
| Operating temperature | from -30 to +60 °C |
| Max operating altitude | 5.000 m |
| Dimensions (W x H x D) | 1.097 x 668 x 340 mm |
| Weight | 108 kg |
Documentation
PDFDatasheet 11010221Official manufacturer documentString sizing must respect the MPPT voltage and current limits and the electrical design of the system. Installation and grid connection must be carried out by qualified personnel in accordance with the applicable standards.