The Sigen Hybrid 8.0 TP is Sigenergy's stand-alone three-phase hybrid inverter rated at 8 kW. It is born "battery ready": it can be installed straight away as a photovoltaic inverter and integrated at a later stage with the SigenStor Battery Controller (BC) and the SigenStor BAT battery modules (1 to 6 modules, battery voltage 600-900 V).
It handles up to 12,800 W of photovoltaic power across 4 MPPTs, with a maximum DC voltage of 1,100 V and an MPPT range of 160-1,000 V. The declared maximum efficiency is 98.3% (European efficiency 97.1%). IP66 protection rating, intelligent air cooling and an operating temperature from -30 to +60 °C allow outdoor installation.
Key features
Technical specifications
| Feature | Value |
|---|---|
| Product code | 11010021 |
| Model | Sigen Hybrid 8.0 TP |
| Rated AC power | 8.000 W |
| Max AC power | 8.800 VA |
| Recommended max PV power | 12.800 W |
| Max PV voltage | 1.100 V |
| MPPT range | 160-1.000 V |
| Number of MPPTs | 4 |
| Strings per MPPT | 1 |
| Max current per MPPT | 16 A |
| Battery voltage | 600-900 V |
| Compatible battery modules | SigenStor BAT 5.0 / 8.0, 1 to 6 modules per controller (requires SigenStor Battery Controller) |
| Max charge/discharge current | Not stated in the datasheet (depends on the battery modules installed) |
| Backup/EPS power | 8,000 W (requires Sigen Gateway) |
| Rated AC current | 12.2 A |
| Max AC current | 13.4 A |
| Grid phase | Three-phase |
| Grid voltage | 380 / 400 V, 3W+N+PE |
| Grid frequency | 50 / 60 Hz |
| Maximum efficiency | 98.3 % |
| European efficiency | 97.1 % |
| Protection rating | IP66 |
| Cooling | Intelligent air cooling |
| Communication | Wi-Fi (WLAN), Fast Ethernet (LAN), RS485, optional Sigen CommMod 4G/3G/2G |
| Protections | PV reverse polarity protection, insulation monitoring, residual current monitoring, arc fault circuit interrupter (AFCI), AC overcurrent/overvoltage/short-circuit protection, type II SPD on the DC and AC side, anti-islanding protection |
| Standards | IEC/EN 62109-1, IEC/EN 62109-2, IEC/EN 61000-6-1, IEC/EN 61000-6-2; CEI 0-21 (certificate of conformity issued for the three-phase models) |
| Operating temperature | from -30 to +60 °C |
| Max operating altitude | 4.000 m |
| Dimensions (W x H x D) | 700 x 300 x 283 mm |
| Weight | 36 kg |
| Installation | Wall-mounted |
| Warranty | 10 years |