Sigenergy Sigen Hybrid 100M1-HYA Hybrid Inverter 100 kW Three-Phase
The Sigen Hybrid 100M1-HYA is Sigenergy's 100 kW commercial and industrial (C&I) three-phase hybrid inverter, the heart of the modular SigenStack system. A single unit combines the photovoltaic inverter and the battery inverter: the dedicated battery port accepts 4 to 21 SigenStack BAT 12.0 modules, with charging and discharging power up to 110,000 W.
The photovoltaic side accepts up to 200,000 Wp on 8 MPPTs (2 strings per tracker, 40 A per MPPT, 160-1,000 V range, maximum DC voltage 1,100 V), also suitable for high-current modules. Maximum efficiency of 98.3%, 380 / 400 / 480 V output, IP66 protection rating and intelligent air cooling. The HYA version is intended for grid-connected systems: the on-/off-grid backup function is available only on the HYB version.
Key features
Technical specifications
| Feature | Value |
|---|---|
| Product code | 11010134 |
| Model | Sigen Hybrid 100M1-HYA |
| Rated AC power | 100.000 W |
| Max AC power | 110.000 VA |
| Recommended max PV power | 200.000 Wp |
| Max PV voltage | 1.100 V |
| Rated PV voltage | 600 V |
| Start-up voltage | 180 V |
| MPPT range | 160-1.000 V |
| Number of MPPTs | 8 |
| Strings per MPPT | 2 |
| Max current per MPPT | 40 A |
| Max short-circuit current per MPPT | 60 A |
| Compatible battery modules | SigenStack BAT 12.0, 4 to 21 modules |
| Max charge/discharge power | 110.000 W |
| Max battery current | 180 A |
| Backup/EPS power | Not available (HYA version without backup) |
| Max AC current | 167.1 A (at 380 / 400 V) |
| Grid phase | Three-phase |
| Grid voltage | 380 / 400 / 480 V, 3W+(N)+PE |
| Grid frequency | 50 / 60 Hz |
| Power factor | from 0.8 leading to 0.8 lagging |
| Maximum efficiency | 98.3 % |
| Protection rating | IP66 |
| Cooling | Intelligent air cooling |
| Communication | Wi-Fi (WLAN), Ethernet (LAN), RS485, optional Sigen CommMod 4G/3G/2G |
| Protections | PV reverse polarity protection, insulation monitoring, residual current monitoring, arc fault circuit interrupter (AFCI), AC overcurrent/overvoltage/short-circuit protection, type II SPD on the DC and AC side, anti-islanding protection |
| Operating temperature | from -30 to +60 °C |
| Max operating altitude | 5,000 m (derating above 4,000 m) |
| Dimensions (W x H x D) | 918 x 640 x 340 mm |
| Weight | 78 kg |
Documentation
PDFDatasheet 11010134Official manufacturer documentString sizing must respect the MPPT voltage and current limits and the electrical design of the system. Installation and grid connection must be carried out by qualified personnel in accordance with the applicable standards.