GoodWe GW20K-ET Hybrid Inverter 20 kW Three-Phase

GoodWe GW20K-ET Hybrid Inverter 20 kW Three-Phase

Regular price €2,998.98
Regular price Sale price €2,998.98
Sale Sold out
Tax included.
Scegli IVA
View full details
VAT note
Businesses and non-Italian private customers: purchase with 22% VAT. The 10% rate is reserved for private customers resident in Italy — find out more.
Foreign companies entitled to 0% VAT: please write to info@litio.store.
Delivery in 10-20 daysHybrid On-GridThree-phaseGoodWe

GoodWe GW20K-ET Hybrid Inverter 20 kW Three-Phase

The GoodWe GW20K-ET is the 20 kW three-phase hybrid inverter of the ET 15-30 kW series, sized for large residential systems, apartment buildings and small businesses that want to pair photovoltaics with high-voltage storage (battery range 200-800 V, 500 V nominal). It features 2 MPPTs with 2 strings each, 30 A per tracker, a maximum PV voltage of 1,000 V and an MPPT range of 200-850 V, for a photovoltaic array of up to 30,000 W.

On the storage side it handles 50 A in charge and discharge, with one independent battery input and charge/discharge power of up to 20,000 W. During a grid outage the three-phase back-up output delivers 20,000 VA (24,000 VA for 60 s, 32,000 VA for 3 s), with a temporary overload that helps start motors and pumps. Maximum efficiency is 98.0% (97.5% European), cooling is by smart fans with noise < 45 dB, the protection rating is IP66 and communications include Wi-Fi, LAN, Bluetooth to the portal, RS485 to the meter and RS485/CAN to the BMS.

Key features

High-voltage storageBattery range 200-800 V with 50 A continuous in charge and discharge and up to 20,000 W of power.
2 MPPTs rated 30 ATwo strings per tracker and PV voltage up to 1,000 V: up to 30,000 W of photovoltaic array.
Three-phase backup with overloadEmergency output of 20,000 VA, with 20,000 VA overload (24,000 VA for 60 s, 32,000 VA for 3 s).
Built-in protectionsType II DC and Type III AC surge arrester, DC switch, insulation and residual current monitoring, remote shutdown; AFCI available.
Built for outdoorsIP66, smart fan cooling and operating temperature from -35 to +60 °C.
Complete monitoringWi-Fi, LAN and Bluetooth to the SEMS portal, RS485 for the meter, RS485/CAN for the battery BMS.

Technical specifications

FeatureValue
Product codeGW20K-ET_WIFILAN-20_AFCI
ModelGW20K-ET
Rated AC power20.000 W
Max AC power22.000 VA
Recommended max PV power30.000 W
Max PV voltage1.000 V
Start-up voltage200 V
MPPT range200-850 V
Rated PV voltage620 V
Number of MPPTs2
Strings per MPPT2
Max current per MPPT30 A
Max short-circuit current per MPPT38 A
Battery typeLithium, high voltage
Battery voltage500 V nominal (range 200-800 V)
Number of battery inputs1
Max charge/discharge current50 A / 50 A
Max charge/discharge power20.000 W / 20.000 W
Backup/EPS power20,000 VA rated - without the grid 20,000 VA (24,000 VA for 60 s, 32,000 VA for 3 s)
Max backup current30.3 A (36.4 A for 60 s, 48.5 A for 3 s)
Grid phaseThree-phase
Grid voltage380/400 V (3L/N/PE)
Grid frequency50/60 Hz (range 45-65 Hz)
Max AC current to the grid31.9 A
Max AC current from the grid30.3 A
Power factor~1 (0.8 leading - 0.8 lagging)
Total harmonic distortion<= 3,05 %
Maximum efficiency98.0 %
European efficiency97.5 %
Max battery-to-AC efficiency97.5 %
MPPT efficiency99.9 %
Surge arrestersDC Type II, AC Type III
AFCIOptional (present in the AFCI version)
Protection ratingIP66
CoolingSmart fans (smart fan cooling)
Noise level< 45 dB
CommunicationWi-Fi, LAN, Bluetooth (portal), RS485 (meter), RS485/CAN (BMS)
User interfaceLED, app via WLAN
Night-time consumption< 15 W
Operating temperature-35 °C ... +60 °C
Relative humidity0-95 %
Max altitude4.000 m
Dimensions (W x H x D)520 x 660 x 220 mm
Weight48 kg
WarrantyGoodWe Limited Warranty: 10 years for residential inverters manufactured from 1 January 2026 (5 years for earlier units), 5 years for commercial and industrial inverters

Documentation

PDFDatasheet GW20K-ET_WIFILAN-20_AFCIOfficial manufacturer document

String sizing must respect the MPPT voltage and current limits and the electrical design of the system. Installation and grid connection must be carried out by qualified personnel in accordance with the applicable standards.