How VAT works ›
SolaX CTSA016 split-core current transformer 100 A/40 mA
The CTSA016 is the 100 A current transformer that works with the SolaX meter to measure the energy exchanged with the grid. It is required in SolaX storage systems, both with a hybrid inverter and with an AC-coupled charger.
It is a split-core type: it clips around the phase cable without cutting it, so installation does not require opening the power circuit. Inner diameter is 16 mm, output is 40 mA with a 2500:1 ratio and class 0.5 accuracy; the secondary leads are 2 m long.
Key strengths
Technical specifications
| Feature | Value |
|---|---|
| Product code | CTSA016 |
| Manufacturer | SolaX |
| Type | Split-core current transformer |
| Input | 100 A |
| Output | 40 mA (AC) |
| Transformation ratio | 2500 : 1 |
| Accuracy class | Class 0.5 |
| Inner diameter | 16 mm |
| Frequency | 50 / 60 Hz |
| Compatibility | SolaX M1-40, M3-40, M3-40-Dual meters and XHub |
| Cable length | 2 m |
| Operating temperature | -40 ~ 85 °C |
| Maximum altitude | Up to 4000 m |
| Certifications | CE, UL, RoHS, REACH |
Documentation
PDFDatasheetTechnical data of the product — CTSA016Three-phase systems need three current transformers, one per phase.