Sigenergy Sigen Hybrid 3.6 SP2 Hybrid Inverter 3.6 kW Single-Phase
The Sigen Hybrid 3.6 SP2 is Sigenergy's second-generation (GEN2) single-phase hybrid inverter rated at 3.6 kW. It is a compact, lightweight unit (11.5 kg, 373 x 473 x 99 mm) with natural convection cooling, and therefore completely silent, designed for single-phase residential systems.
It accepts up to 7,360 W of photovoltaic power on 2 MPPTs (16 A per tracker, range 50-550 V, maximum DC voltage 600 V) and reaches a maximum efficiency of 98.6%. It is battery ready: storage is added by connecting the SigenStor Battery Controller (BC) with 1 to 6 SigenStor BAT modules (battery voltage 300-600 V). Off-grid it delivers up to 5,520 W peak for 10 seconds.
Key features
Technical specifications
| Feature | Value |
|---|---|
| Product code | 11020006 |
| Model | Sigen Hybrid 3.6 SP2 |
| Rated AC power | 3.680 W |
| Max AC power | 3.680 VA |
| Recommended max PV power | 7.360 W |
| Max PV voltage | 600 V |
| Rated PV voltage | 350 V |
| Start-up voltage | 100 V |
| MPPT range | 50-550 V |
| Number of MPPTs | 2 |
| Strings per MPPT | 1 |
| Max current per MPPT | 16 A |
| Max short-circuit current per MPPT | 22 A |
| Battery voltage | 300-600 V |
| Compatible battery modules | SigenStor BAT, 1 to 6 modules per SigenStor Battery Controller |
| Max charge/discharge current | Not stated in the datasheet |
| Backup/EPS power | 3,680 W, 5,520 W peak for 10 s (requires Sigen Gateway) |
| Rated AC current | 16 A |
| Max AC current | 16 A |
| Grid phase | Single-phase |
| Grid voltage | 220 / 230 / 240 V |
| Grid frequency | 50 / 60 Hz |
| Maximum efficiency | 98.6 % |
| European efficiency | 98.1 % |
| Protection rating | IP66 |
| Cooling | Natural convection |
| Communication | Wi-Fi (WLAN), Fast Ethernet (LAN), RS485, optional Sigen CommMod 4G/3G/2G |
| Protections | PV reverse polarity protection, insulation monitoring, residual current monitoring, arc fault circuit interrupter (AFCI), AC overcurrent/overvoltage/short-circuit protection, type II SPD on the DC and AC side, anti-islanding protection |
| Operating temperature | from -30 to +60 °C |
| Max operating altitude | 4.000 m |
| Dimensions (W x H x D) | 373 x 473 x 99 mm |
| Weight | 11.5 kg |
| Installation | Wall-mounted |
| Warranty | 10 years |