Skip to product information
1 of 3

Milesight

Smart home kit laboratories, gym and canteen LoRaWAN Milesight: air quality, methane gas, footfall, noise, microclimate and SOS buttons

Smart home kit laboratories, gym and canteen LoRaWAN Milesight: air quality, methane gas, footfall, noise, microclimate and SOS buttons

Regular price €1,582.79
Regular price Sale price €1,582.79
Sale Sold out Excl. VAT — calculated in the cart
Version
Connectivity
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

AVAILABILITY

Product available, quantity not tracked

Shipping

  • Italy: €13 on orders up to €150, free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
School kit · laboratories, gym and canteen
Laboratories, gym and canteen kit, 1 school

Particulates, volatile compounds and CO2 in the laboratories, methane detection in the chemistry laboratory and in the kitchen, footfall at the canteen, noise, microclimate of the gym and SOS buttons. LoRaWAN radio transmission, data and notifications from the app.

Milesight devices Alarms on the smartphone No cameras Local siren on the gas
Customisable kits. This is one of the Milesight LoRaWAN kits in the Smart Home section. For different installations, custom kits or bespoke automations, write to us from the contact section.
Air in the laboratoriesPM2.5, PM10, volatile compounds, CO2, temperature and humidity, with display and traffic-light signal.
Methane gasTwo detectors with siren, relay output and output for a shut-off solenoid valve.
Footfall and noiseEntries and exits at the canteen to organise the sittings, sound level in the canteen and the gym.
SOS buttonsOne press in the laboratories and the call reaches the smartphone of the people indicated.

What it does

  • In the two laboratories a wall-mounted monitor measures fine particulates (PM2.5 and PM10), volatile organic compounds, CO2, temperature, humidity, pressure and light. The display, the traffic-light LED and the buzzer warn whoever is in the laboratory when the thresholds are exceeded.
  • In the chemistry laboratory and in the canteen kitchen a methane detector sounds at 85 dB, sends the notification and can drive an extractor fan or a siren on the spot (relay output) and a gas shut-off solenoid valve (12 V pulse output).
  • The people counter at the canteen entrance counts entries and exits in both directions without recording images: the chart by time slot serves to spread out the sittings.
  • The noise sensors in the canteen and in the gym record the sound level in dBA, with average and peak values.
  • In the gym two watertight temperature and humidity sensors keep the microclimate of the hall and of the changing rooms under control.
  • The SOS buttons in the laboratories send an immediate call to the designated people: the technical office, the deputy head, the first-aid staff.
  • History, charts and notifications can be consulted from a smartphone and from a PC.
For more laboratories, more gyms or more sites, to add the monitoring of CO2 in the classrooms, if the gym and the canteen are in separate buildings and a different gateway is needed, if there is no data line in the building: tell us the characteristics of your school from the contact section and we will propose the correct configuration together with the quotation.
Laboratories, gym and canteen kit Litio Store: installation diagram in a technical school with laboratories, gym and canteen
1Compact indoor LoRaWAN gateway, connected to the school network: it collects the data from all the sensors and takes it to the cloud.
2Air quality monitor with fine particulates, on the wall at least 1.5 m above the floor. One per laboratory, two in the kit.
3Methane detector, high on the wall, 10-30 cm below the ceiling. One in the chemistry laboratory, one in the canteen kitchen.
4People counter above the canteen entrance, facing the floor.
5Noise sensor, one in the canteen and one in the gym.
6IP67 temperature and humidity sensor in the gym: one in the hall, one in the changing rooms.
7Red wall-mounted SOS button, one per laboratory.

How it is installed

Gateway. Compact indoor gateway, on a piece of furniture, on the wall or on the ceiling, in a central position among the laboratories, the canteen and the gym: a corridor or a technical room with a network socket or the school Wi-Fi. USB-C 5 V power supply, Ethernet or Wi-Fi connection. IP30, operation from -20 to +50 °C: in dry rooms only. If the gym is a building of its own, the variant with the longer-range gateway is chosen or a second gateway is added.
Laboratories: air monitor and SOS buttons. Monitor on the wall at least 1.5 m above the floor, away from windows, doors, heat sources and strong draughts, so not next to fume hoods and extraction grilles. Fixing with double-sided tape or wall plugs, plus the anti-theft screw. Power supply from a USB-C 5 V socket is recommended: on batteries the life is about one year. After a long period in storage the volatile compounds sensor stabilises in 2-7 days. SOS button on the wall with double-sided tape or screws, in a spot everyone can reach, near the door or the teacher's bench. Monitor and buttons are IP30, for indoor use.
Methane detectors. On the wall, high up, because methane is lighter than air: between 10 and 30 cm below the ceiling and at a horizontal distance of between 1.5 and 4 m from the gas appliance (hob, bench with the burners). Not behind furniture or metal objects, not next to doors, windows and fume hoods, not in dusty spots or spots wetted by steam. Bracket with two wall plugs. 12 V power supply with the power unit included: a socket within reach of the cable is needed. After switching on, the sensor warms up for about 3 minutes. The test button checks the LED, the siren and the relay.
Canteen and gym. People counter on the ceiling or on the lintel of the canteen entrance, between 2 and 3 m high, facing the floor: it covers an opening of 1.6 m at a height of 2 m and of 3.6 m at 3 m. Away from air curtains, air conditioners and heat sources, with no metal objects immediately below. Noise sensors 1.2-1.5 m above the floor, at least 1 m from walls and reflecting surfaces and about 1.5 m from doors and windows, not right up against the source; in the gym, out of the path of the balls. Temperature and humidity sensors on the wall with two screws or with a cable tie on an upright, away from unit heaters and large doors.
Configuration. Via NFC with a smartphone and the manufacturer's free app: reading intervals, thresholds, names of the rooms, recipients of the SOS calls. The gateway is configured from a browser. No cables or paid software are needed.
Documentation included. Written installation guide with heights, distances from the gas appliances, positions to avoid, the diagram of the methane detector outputs and the switch-on sequence, and the initial configuration of thresholds, rooms and notification recipients indicated when ordering.

What is in the kit

Laboratories, gym and canteen kit Litio Store: the devices included
Qty Device What it is for
1 Compact indoor LoRaWAN gateway, Ethernet and Wi-Fi It collects the data from the sensors and sends it to the cloud through the school network.
2 9-parameter air quality monitor with display PM2.5, PM10, volatile compounds, CO2, temperature, humidity, pressure, light and presence in the laboratories.
2 Methane gas detector with siren, relay and output for a solenoid valve Local alarm and notification in the chemistry laboratory and in the kitchen.
1 Thermopile people counter, bidirectional Entries and exits at the canteen, without images.
2 Sound level sensor, 30-120 dBA Noise in the canteen and in the gym.
2 Temperature and humidity sensor, IP67 Microclimate of the hall and the changing rooms of the gym.
2 SOS button Emergency call from the laboratories.

Milesight devices of the highest quality with the manufacturer's warranty. Batteries included in the battery-powered sensors; the gateway and the methane detectors are mains powered, for the air monitors the USB-C power supply is recommended.

Available connectivity options

  • School network (Ethernet/Wi-Fi): 1 compact indoor LoRaWAN gateway
  • Built-in 4G: 1 compact LoRaWAN gateway with 4G. SIM not included
  • Large building (Ethernet/Wi-Fi, PoE): 1 semi-industrial LoRaWAN gateway

In the complete kit the material for the gateway (network cable, pole, PoE injector) changes accordingly. The SIM for the 4G versions is not included.

Choose the version

Devices only
The price updates at the top when you choose version, connectivity and size.
  • The Milesight devices in the table
  • Installation guide and initial configuration
  • For those who already have power points, a network cable and fixing material
Recommended
Complete kit with installation material
The price updates at the top when you choose version, connectivity and size.
  • Everything in the basic version
  • 5 m Cat6 Ethernet cable to connect the gateway to the switch
  • 2 spurs at 230 V with modular switch, box, cable and terminals, to bring the power supply close to the methane detectors
  • Stainless steel clamps to fix the gym sensors to uprights and tubulars
  • Wall plugs, screws, double-sided tape, cable ties and adhesive cable clips
  • Numbered labels for the devices and installation diagram

Before you order

Is the school network needed?

It is needed only by the gateway: an Ethernet socket or Wi-Fi, with outbound internet access allowed. The sensors do not use Wi-Fi, they talk to the gateway by radio. If there is no data line in the building the version with the 4G gateway is available, which requires a data SIM (not included, any operator, traffic below 1 GB per month). It is chosen when ordering.

Does one gateway cover the laboratories, the canteen and the gym?

Inside a building the range depends on walls and floor slabs: the gateway goes in a central position with respect to the rooms monitored. If the laboratories, the canteen and the gym are in the same block, the compact gateway is sufficient. With the gym in a separate building, very thick walls, several floors or a campus the «large building» variant is preferable, with a semi-industrial gateway with greater range, IP65 and PoE power supply; alternatively a second gateway is added. One gateway handles about 2,000 devices.

Which gases does it detect and what can the detector drive?

It detects only the methane of the town gas supply. It does not detect LPG, carbon monoxide or the vapours of laboratory reagents: if the kitchen or the laboratory is supplied with LPG in cylinders or in a tank, this detector is not suitable. In alarm it sounds at 85 dB and closes a relay contact rated 250 V and 10 A, which can be used for an extractor fan or a siren; a second 12 V pulse output drives a pulse-type gas shut-off solenoid valve. The solenoid valve, the extractor fan and the relevant connections are not included. The sensor has a life of 5 years from switch-on, after which the detector has to be replaced.

Does the people counter film the students?

No. It uses a thermal matrix sensor, with no camera: it produces no images and identifies nobody. It counts the passages in both directions with a stated accuracy of up to 90%: it is a footfall figure for organising sittings and staff, not an attendance register.

Who receives the call from the SOS button?

The people indicated in the configuration, with an immediate notification on the app. The button distinguishes a short, a long and a double press, and confirms the sending with an LED and a buzzer. The call goes through the gateway and through the internet: the button complements, and does not replace, the alarm devices and the emergency procedures laid down in the school's plan.

We have more laboratories or more sites

The kit is configured on the school: for each additional laboratory an air monitor and an SOS button are added, for each room with methane appliances a detector; the gateway and the platform stay the same. Write to us from the contact section stating the number of laboratories, rooms with gas, canteen entrances and the distance between the buildings: we will send you the composition and the quotation for the adapted kit.

Battery life and power supply

The gateway and the methane detectors go to a socket. The air monitors run on batteries for about one year, because measuring the particulates consumes power: for a permanent installation a USB-C 5 V socket is preferable. The people counter is powered by USB-C 5 V or by batteries, depending on the version supplied; on batteries it lasts about 1.7 years. Noise sensors from 3 to 5 years, temperature and humidity sensors from about 6 to more than 10 years, SOS buttons more than 7 years. All the batteries are lithium, replaceable, with the level visible in the app.

Where is the data consulted and are there any fees?

On the manufacturer's app and portal, from smartphone and PC, with charts, thresholds and notifications; no fee for basic use. Where there is a building management system or a platform belonging to the owning authority, the gateway can also send the data to that system (MQTT or HTTP): the configuration is included.

What happens if there is no internet?

The methane detectors sound and operate their own outputs on the spot, with no need for the network. The air monitors keep showing the values on the display and keep the readings in memory, as do the people counter and the gas detectors. Notifications, SOS calls and the history on the portal resume when the line comes back.

Is an electrician necessary?

For installing the battery-powered sensors, no: they are fixed with screws, cable ties or double-sided tape. An electrician is needed if there are no sockets near the methane detectors, which have to be mounted high up, or near the air monitors, and to connect the detector outputs to an extractor fan, a siren or a solenoid valve. Work on the gas system is the job of a qualified installer.

What is not included
  • The gas shut-off solenoid valve, extractor fans and external sirens, with the relevant connections
  • The data SIM, in the version with the 4G gateway
  • The power sockets for the methane detectors, the air monitors and the gateway
  • The smartphone with NFC for the configuration
  • In the "devices only" version: network cable, electrical spurs, clamps and small fittings

Shipping

Shipping: free in Italy and throughout the EU. Delivery in 10-20 working days.