Pallet of 36 LONGi Hi-MO X10 Explorer LR7-72HVH-650M 650 W monofacial solar modules — 23.4 kWp
A full pallet of 36 LONGi Hi-MO X10 Explorer LR7-72HVH-650M modules rated 650 W each, 23.4 kWp in total. It ships as the manufacturer packed it — strapped and sealed at the factory — so you buy once, unload once, and the price per watt comes in below the single-module price.
Each module converts 24.1 % of the incident light, and one pallet carries 23.4 kWp across 36 pieces. We have 263 full pallets on hand, which means a residential or small commercial array can be built from a single production batch — worth having, because modules from one batch share the same power tolerance.
That works out to roughly €0.1845 per Wp excluding VAT. Delivery needs a site a truck can reach and a forklift or pallet truck on hand: the pallet weighs 1026 kg, so it cannot be moved by hand.
Why it is worth it
Technical data
| Specification | Value |
|---|---|
| What you get | One complete pallet |
| Modules included | 36 pcs |
| Total output | 23.4 kWp |
| Delivery | 10-20 days |
| Product code | LR7-72HVH-650M |
| Manufacturer | LONGi |
| Series | Hi-MO X10 Explorer |
| Rated power (STC) | 650 Wp |
| Module efficiency | 24.1 % (computed from power and area) |
| Voltage at Pmax (Vmp) | 44.56 V |
| Current at Pmax (Imp) | 14.59 A |
| Open-circuit voltage (Voc) | 53.9 V |
| Short-circuit current (Isc) | 15.29 A |
| Bifacial | No |
| Frame | black frame |
| Dimensions (L × W × D) | 2382 × 1134 × 30 mm |
| Weight | 28.5 kg per module |
| Maximum system voltage | 1500 V DC |
| Maximum series fuse rating | 25 A |
| Performance warranty | 30 years (linear) |