Skip to product information
1 of 1

Huawei

Huawei DTSU666-H Three-Phase Meter Smart Power Sensor 100 A with 3 Split-Core CTs

Huawei DTSU666-H Three-Phase Meter Smart Power Sensor 100 A with 3 Split-Core CTs

Regular price €160.00
Regular price Sale price €160.00
Sale Sold out Excl. VAT — calculated in the cart
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

AVAILABILITY

26 units in stock at our supplier

Shipping

  • Italy: €13 on orders up to €150, free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysMetering & sensorsAC sideHuawei

Huawei DTSU666-H Three-Phase Meter Smart Power Sensor 100 A with 3 Split-Core CTs

The Huawei DTSU666-H in the 100 A version is the three-phase Smart Power Sensor for photovoltaic systems and storage systems with Huawei SUN2000 inverters. It measures voltage, current, active and reactive power, power factor and energy on the three phases in real time, distinguishing the energy drawn from the grid from the energy fed into it.

It is installed in the distribution board on a 35 mm DIN rail at the connection point and communicates with the inverter via RS485 with Modbus-RTU protocol. Measurement is indirect through three 100 A split-core current transformers with a 40 mA secondary, which are clamped onto the phase cables without having to cut them. It enables self-consumption management, export limitation and monitoring of energy flows in FusionSolar.

Key features

Complete three-phase measurementDetects the electrical quantities on all three phases in 3P4W (and 3P3W) networks, with separate counting of imported and exported energy.
Three 100 A split-core CTsThe 100 A / 40 mA split-core current transformers are fitted onto the phase conductors without breaking the line.
Accuracy class 1Active energy measurement in class 1 according to Huawei documentation.
RS485 Modbus-RTUDirect connection to SUN2000 inverters and to Smart Dongles / SmartLogger; baud rate 4800 or 9600 bps (9600 by default).
Service LCD displayShows the measurements and allows the address and communication parameters to be set on site.
Low consumptionConsumption on the voltage circuit ≤ 1.5 W / 6 VA, with operation from −25 °C to +60 °C.

Technical specifications

FeatureValue
Product codeDTSU_100A
ModelDTSU666-H 100 A
PhasesThree-phase (3P4W / 3P3W)
Rated voltage230 V AC / 400 V AC, 50/60 Hz
Nominal current0 – 100 A
Measurement typeIndirect with 3 split-core CTs 100 A / 40 mA (included)
Accuracy classClass 1 (active energy)
CommunicationRS485, Modbus-RTU protocol (4800 / 9600 bps, default 9600)
Energy reading range0,00 kWh – 999999,9 kWh
Own power consumption≤ 1.5 W / 6 VA (voltage circuit); ≤ 0.2 – 0.4 VA (current circuit)
Mounting35 mm DIN rail
Operating temperature−25 °C … +60 °C
Relative humidity≤ 75 %
Protection ratingNot stated by the manufacturer
Dimensions72 × 100 × 66 mm
Weight0.4 kg

Documentation

PDFDatasheet DTSU_100AOfficial manufacturer document

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.