Skip to product information
1 of 1

Noark

Noark 108411 Ex9L-N Selective RCCB 4P 63 A 300 mA Type A S

Noark 108411 Ex9L-N Selective RCCB 4P 63 A 300 mA Type A S

Regular price €79.80
Regular price Sale price €79.80
Sale Sold out Excl. VAT — calculated in the cart
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

AVAILABILITY

Product available, quantity not tracked

Shipping

  • Italy: €13 on orders up to €150, free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysProtection deviceAC sideNoark

Noark 108411 Ex9L-N Selective RCCB 4P 63 A 300 mA Type A S

The Noark 108411 is a pure residual current circuit breaker (RCCB) of the Ex9L-N series in a four-pole selective version: rated current 63 A, rated residual current 300 mA, Type A with S characteristic (selective, time-delayed tripping). It takes up 4 modules on the DIN rail, with a conditional short-circuit current of 6 kA.

The S characteristic introduces an intentional delay in tripping, so that in the event of an earth fault the high-sensitivity residual current device installed downstream trips first: it is therefore the correct device to use as the main residual current device in a two-level selective protection structure, where the 30 mA devices protect the individual lines and the 300 mA selective device provides back-up protection and protection against the risk of fire caused by earth fault currents. Thanks to selectivity, a fault on a final circuit does not put the entire installation out of service. Type A also detects pulsating unidirectional leakage currents. Being a pure RCCB, it does not protect against overload and short circuit.

Key features

Selective S characteristicTime-delayed tripping ensures discrimination with the 30 mA devices installed downstream, preventing a local fault from de-energising the whole board.
300 mA thresholdA typical value for a main residual current device, aimed at protection against the risk of fire caused by earth fault currents.
63 A four-pole ratingSized as the main device of three-phase 3P+N boards up to 63 A.
Type AAlso trips in the presence of pulsating unidirectional leakage currents generated by electronic loads.
Voltage-independent operationThe electromagnetic mechanism guarantees tripping even without mains voltage.
6 kA short-circuit withstandRated conditional short-circuit current of 6 kA with coordinated back-up protection.

Technical specifications

FeatureValue
Product code108411
Device typeSelective pure residual current circuit breaker (RCCB), Ex9L-N series
System sideAlternating current (AC)
Number of poles / phases4 poles (three-phase 3P+N)
Nominal current63 A
Rated residual current300 mA (0,3 A)
RCD typeType A, S characteristic (selective, time-delayed)
Rated voltage (Ue)400 V AC (230 V phase-to-neutral)
Rated frequency50 Hz
Conditional short-circuit current6 kA
Miniature circuit breaker (MCB)Not included (pure RCD, to be combined with MCBs)
Number of DIN modules4
Protection ratingIP20
Mounting35 mm DIN rail
Dimensions79 × 89 × 72 mm
Weight0.37 kg
StandardsIEC/EN 61008-1 (residual current devices without integral overcurrent protection)

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.