Skip to product information
1 of 1

Phoenix Contact

DC Surge Arrester Type 1+2 Phoenix Contact 1099593 VAL-MS-T1/T2 1000DC-PV/2+V-FM with Contact

DC Surge Arrester Type 1+2 Phoenix Contact 1099593 VAL-MS-T1/T2 1000DC-PV/2+V-FM with Contact

Regular price €76.11
Regular price Sale price €76.11
Sale Sold out Excl. VAT — calculated in the cart
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

AVAILABILITY

1 unit in stock at our supplier

Shipping

  • Italy: €13 on orders up to €150, free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysProtection deviceDC sidePhoenix Contact

DC Surge Arrester Type 1+2 Phoenix Contact 1099593 VAL-MS-T1/T2 1000DC-PV/2+V-FM with Contact

The Phoenix Contact VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 (article number 1099593) is a combined Type 1+2 arrester for the direct current side of photovoltaic systems up to 1170 V DC. It is to be used when the building is equipped with a lightning protection system (LPS) or when there is a risk of direct lightning current on the DC line: the device discharges both the current from a direct lightning strike (Iimp 5 kA, 10/350 µs wave) and the induced and switching surges (In 15 kA, 8/20 µs wave).

The structure uses a Y configuration (2+V) with three protection paths — L+ / L−, L+ / PE and L− / PE — on a three-position base with pluggable, thermally monitored cartridges and an optical status indicator on each module. The FM version adds a remote signalling contact that makes it possible to report the end of life of a protection element to the monitoring system or to the datalogger, a function that is particularly useful in unattended installations. Installation is on a 35 mm DIN rail in the DC combiner box, upstream of the inverter.

Key features

Combined Type 1+2 protectionA single device covers both the current from a direct lightning strike (10/350 µs) and the induced and switching surges (8/20 µs).
Suitable for strings up to 1170 V DCThe Ucpv of 1170 V DC makes it compatible with photovoltaic generators with a 1000 V DC system voltage.
Remote signalling contact (FM)The auxiliary contact reports the end of life of a protection element to a remote monitoring system, useful on unattended installations.
Three-path Y configurationThe L+/L−, L+/PE and L−/PE paths with a series spark gap cancel out the leakage current to earth in normal service.
Monitored pluggable cartridgesThe protection elements are plug-in replaceable without touching the wiring; every module has an optical status indicator.
DIN rail mounting3-position base for a 35 mm rail, screw terminals up to 35 mm² solid, IP20 rating with the terminals occupied.

Technical specifications

FeatureValue
Product code1099593
Product typeCombined lightning current and surge arrester for photovoltaic systems
System sideDirect current (DC), between the PV generator and the inverter
Brand and modelPhoenix Contact VAL-MS-T1/T2 1000DC-PV/2+V-FM/40 — item no. 1099593
Surge protective device (type)Type 1+2 (class I + II)
Maximum continuous operating voltage Ucpv1170 V DC
Lightning impulse current Iimp (10/350 µs)5 kA per mode
Nominal discharge current In (8/20 µs)15 kA
Maximum discharge current Imax (8/20 µs)40 kA
Protection level Up≤ 3,5 kV
Protection modes3 (L+ / L−, L+ / PE, L− / PE) — Y "2+V" configuration
Remote signallingYes, remote signalling contact (FM version)
Protective devices3 thermally monitored pluggable cartridges, with optical status indicator
Mounting35 mm DIN rail (3-position base)
Connection cross-sectionUp to 35 mm² rigid / 25 mm² flexible (M5 screw terminals)
Protection ratingIP20 (with all terminals occupied)
Operating temperatureFrom −40 °C to +80 °C
Dimensions54.00 × 100.00 × 65.70 mm
Weight0.38 kg
StandardsEN 61643-31 / IEC 61643-31

Documentation

PDFDatasheet 1099593Official manufacturer document

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.