DC Surge Arrester Type 1+2 Phoenix Contact 2801163 VAL-MS-T1/T2 600DC-PV/2+V 720 V

DC Surge Arrester Type 1+2 Phoenix Contact 2801163 VAL-MS-T1/T2 600DC-PV/2+V 720 V

Regular price €126.71
Regular price Sale price €126.71
Sale Sold out Excl. VAT — calculated in the cart
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

AVAILABILITY

147 units in stock at our supplier

Shipping

  • Italy: €13 on orders up to €150, free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysProtection deviceDC sidePhoenix Contact

DC Surge Arrester Type 1+2 Phoenix Contact 2801163 VAL-MS-T1/T2 600DC-PV/2+V 720 V

The Phoenix Contact VAL-MS-T1/T2 600DC-PV/2+V (article number 2801163) is a combined Type 1+2 arrester for the direct current side of photovoltaic systems with a continuous operating voltage of up to 720 V DC. It is the right choice when the building is protected by an LPS lightning protection system or when direct lightning current may flow along the DC line: the device is tested with a 10/350 µs wave (Iimp 5 kA) as well as with the classic 8/20 µs wave of induced surges.

It is installed on a 35 mm DIN rail in the DC combiner box, between the photovoltaic generator and the inverter. The structure uses a Y configuration (2+V) with three protection paths — L+ / L−, L+ / PE and L− / PE — on a three-position base that houses three pluggable, thermally monitored cartridges, each with an optical status indicator. The particularly low protection level (Up ≤ 2.6 kV) suits the impulse withstand of the DC inputs of 600 V string inverters.

Key features

Combined Type 1+2 protectionIt discharges both the current from a direct lightning strike (Iimp 5 kA, 10/350 µs) and the induced and switching surges (In 15 kA, 8/20 µs).
Sized for 600 V DC stringsThe maximum operating voltage Ucpv of 720 V DC covers photovoltaic generators with a system voltage of up to 600 V DC.
Contained protection levelUp ≤ 2.6 kV: a low value that safeguards the inverter's DC inputs and the string cables.
Three-path Y configurationThe L+/L−, L+/PE and L−/PE paths with a series spark gap eliminate the leakage current to earth in normal service.
Pluggable cartridges with optical indicatorThe three thermally monitored elements are plug-in replaceable and give a visual indication when they reach their end of life.
DIN rail installation3-position base for a 35 mm rail, screw terminals up to 35 mm² solid, IP20 with the terminals occupied.

Technical specifications

FeatureValue
Product code2801163
Product typeCombined lightning current and surge arrester for photovoltaic systems
System sideDirect current (DC), between the PV generator and the inverter
Brand and modelPhoenix Contact VAL-MS-T1/T2 600DC-PV/2+V — item no. 2801163
Surge protective device (type)Type 1+2 (class I + II)
Maximum continuous operating voltage Ucpv720 V DC
Lightning impulse current Iimp (10/350 µs)5 kA per mode
Nominal discharge current In (8/20 µs)15 kA
Maximum discharge current Imax (8/20 µs)40 kA
Protection level Up≤ 2,6 kV
Protection modes3 (L+ / L−, L+ / PE, L− / PE) — Y "2+V" configuration
Protective devices3 thermally monitored pluggable cartridges, with optical status indicator
Mounting35 mm DIN rail (3-position base)
Connection cross-sectionFlexible from 1.5 to 25 mm²; rigid from 1.5 to 35 mm²
Protection ratingIP20 (with all terminals occupied)
Pollution degree2 — indoor installation
Operating temperatureFrom −40 °C to +80 °C
Dimensions53.4 × 89.8 × 65.7 mm
Weight0.365 kg
StandardsEN 50539-11

Documentation

PDFDatasheet 2801163Official manufacturer document

Installation and wiring must be carried out by qualified personnel in accordance with the applicable standards and the electrical design of the system.