Skip to product information
1 of 1

Noark

Noark 103334 Surge Protective Device Type 1+2 275 V 12.5 kA 1P+N

Noark 103334 Surge Protective Device Type 1+2 275 V 12.5 kA 1P+N

Regular price €111.05
Regular price Sale price €111.05
Sale Sold out Excl. VAT — calculated in the cart
  • Prices exclude VAT: tax is calculated in the cart based on the delivery country.
  • EU businesses: 0% VAT with a VAT number valid in VIES — the field appears at checkout, below the delivery address.
  • Reduced 10% VAT on solar and storage for customers in Italy: write to us before ordering.

AVAILABILITY

Product available, quantity not tracked

Shipping

  • Italy: €13 on orders up to €150, free shipping over €150.
  • European Union: 60 € per order, with no threshold

Rates apply to the cart total and are confirmed at checkout, where shipping to countries outside the EU is also calculated.

View full details
Delivery in 10-20 daysProtection deviceAC sideNoark

Noark 103334 Surge Protective Device Type 1+2 275 V 12.5 kA 1P+N

The Noark 103334 is a modular surge protective device (SPD) of the Ex9UE1+2 series, in combined class Type 1+2 and 1P+N (2 modules) configuration. It is based on varistors with pluggable, replaceable functional modules, has a maximum continuous operating voltage of Uc 275 V and a protection level of Up 1.5 kV.

It is installed in the single-phase main board, at the origin of the installation, typically immediately downstream of the meter or the main switch, and it is the device to use when the building is equipped with a lightning protection system (LPS) or is exposed to direct lightning strikes: the Type 1 class discharges a lightning impulse current Iimp of 12.5 kA with a 10/350 µs waveform, while the Type 2 function limits surges of indirect and switching origin. Thanks to the modular design, in the event of repeated operation it is enough to replace the exhausted cartridge — indicated by the optical indicator on the front — without removing the device from the DIN rail. It is suitable for TN-C-S, TN-S, TT and IT networks.

Key features

Combined class Type 1+2A single device covers both lightning current discharge and the limitation of induced and switching surges.
Iimp 12.5 kA (10/350 µs)Lightning current discharge capacity suited to buildings with a lightning protection system, LPL levels III and IV according to EN 62305.
Protection level Up 1.5 kVLimits the residual voltage on both the L-N and the N-PE path, protecting equipment of a lower overvoltage category.
Pluggable cartridgesThe functional modules are quickly replaced at end of life, without removing the base from the DIN rail or redoing the wiring.
Optical status indicatorA window on the front indicates an exhausted module and the need for replacement.
Terminals up to 50 mm²Accepts rigid, stranded and flexible conductors up to 50 mm², compatible with the cross-sections required for low-impedance earth connections.

Technical specifications

FeatureValue
Product code103334
Device typeModular surge protective device (SPD), Ex9UE1+2 series
System sideAlternating current (AC)
Surge protective device (type)Type 1+2 (class I+II)
Number of poles / phases1P+N (2 poles, single-phase)
Maximum continuous operating voltage (Uc)275 V AC
Protection level (Up) L-N1.5 kV
Protection level (Up) N-PE1.5 kV
Lightning impulse current (Iimp 10/350 µs)12.5 kA
Follow current extinguishing capability100 kA
Specific energy (W/R)156,25 kJ/Ω
Replaceable modulesYes, pluggable functional cartridges
IndicationFront optical status indicator
Remote signalling contactNo
Compatible grid systemsTN-C-S, TN-S, TT, IT (not suitable for TN-C and for direct current)
Power dissipation0.1 W
Terminal cross-sectionUp to 50 mm² (rigid, stranded and flexible)
Number of DIN modules2
MountingTH-35 mm DIN rail
Dimensions68 × 83 × 35 mm
Weight0.12 kg
StandardsEN 61643-11 (SPDs for low-voltage distribution networks); lightning protection levels LPL III and IV according to EN 62305