Lynx Class-T Power In
Two Class T fuses on a 1000A busbar, inside the Lynx system
1000A DC busbar · 2 fuse positions · 9-60Vdc · lugs to 120mm²
This is the module that brings Class T protection into a Victron Lynx distribution system. It carries two Class T fuses, one per battery string, on a tinned copper busbar rated 1000A DC continuous. Lynx modules bolt to each other to form one continuous positive and negative bar, so with three or more battery strings you simply add another module.
Only 225-400A fuses fit, and they are not included. The fuse studs are 3/8" with 46.7mm centres, which is the large Class T format: the 110-200A sizes have an M8 hole at 42.86mm centres and will not go in. Victron does not stock the fuses, so order them with the module. MEGA fuses do not fit either: those belong in the Lynx Distributor.
Technical data
| Part number | LYN060404010 · EAN 8719076062967 |
| Class T fuse positions | 2, one per battery string |
| Fuse sizes accepted | 225A, 250A, 300A, 350A, 400A |
| Voltage range | 9-60Vdc (12V, 24V, 48V systems) |
| Busbar current | 1000A DC continuous |
| Maximum through the fuses | 800A (2×400A) |
| Busbar thread | M10, 8×30mm tinned copper bar |
| Fuse fixing | 3/8" studs, bolts and nuts marked black. On units with a serial starting HQ the fuse hardware is M10 and unmarked |
| Lugs accepted | up to 120mm² (4/0 AWG), M10 hole, 33Nm |
| Enclosure | ABS, IP20, 279×169×97mm, 2.1kg |
| Temperature | −40÷60°C, 95% humidity non-condensing |
| Fuses included | no |
What it is for
It is the fused entry point of the DC bus: battery strings come in through the fuses, everything else hangs off the common busbar, and there is a system earthing point on board. Fuse each string individually rather than protecting the whole bank behind one fuse: that way a single battery fault does not take the bank down and you can see which string opened.
Fitting it
- Bolt the module to the adjacent Lynx modules so the internal bars make one continuous run.
- Land the battery cables on the M10 busbar with ring lugs, torqued to 33Nm.
- Fit one Class T fuse per string, with the system isolated.
- If a fuse flange does not sit flat on the bar, rotate the fuse 180° about its long axis: the manual calls this out explicitly.
- Connect the DC system earthing point as the installation requires.
MEGA, Class T or NH: which fuse to choose
Three fuse families are actually used on the DC side of a 48V battery system, and they are interchangeable neither mechanically nor in performance.
↔ swipe the table sideways
| Victron MEGA 80V | Class T | NH gPV 1000V DC | |
|---|---|---|---|
| DC voltage rating | 80V | 125V fuse / 160V holder | 1000V |
| DC interrupting rating | not published by the manufacturer | 20,000A | 20kA |
| Connection | direct M8 bolt, 50.8mm hole centres | 3/8" studs (225-400A) or M8 (110-200A) | knife contacts: the cable lands on the base, never on the fuse |
| Where it mounts | already built into the Victron Lynx Distributor, with a status LED per position | Victron Lynx Class-T Power In (2 positions, M10 busbar) or a stand-alone holder | NH fuse base PK0/PK1/PK2/PK3, screw-mounted on the panel |
| When to pick it | residential and light commercial systems built around a Lynx busbar: the most compact and the cheapest | large LiFePO4 banks, where a published DC interrupting rating matters. The reference choice in marine and professional off-grid | industrial switchboards, inspectable isolation, cable up to 240mm² |
Delivery
- Delivered in 10-20 days
- Shipping across Italy and the European Union
- Not sure which size you need? Send us the maximum discharge current from your battery manual and the cable cross-section, and we will tell you